FRU Removal and Replacement
249
8. At the Hardware View, choose Logs > Event Log. The Event Log displays.
Ensure the following event codes display in the log:
— 600—SBAR card hot-insertion initiated.
— 601—SBAR card hot-insertion completed.
If an event code 601 does not display in the log, go to “
” on page 45 to isolate the problem.
9. Perform one of the following to verify SBAR operation:
— At the Hardware View, observe the graphic representing the replacement
card and ensure no alert symbols display that indicate a failure (yellow
triangle or red diamond). If a problem is indicated, go to “
” on page 45 to isolate the problem.
— At the EWS interface, open the Switch tab at the View panel and ensure
no amber LEDs illuminate that indicate an SBAR failure. If a problem is
indicated, go to “
” on page 45 to isolate the
problem.
10. At the Hardware View, double-click the graphic representing the
replacement SBAR assembly to open the FRU Properties dialog box. Verify
that information (FRU name, position, and state) is correct. If a problem is
indicated, go to “
” on page 45 to isolate the problem.
11. Perform the data collection procedure (“
12. If the customer requests the replacement SBAR assembly be set as the active
SBAR, perform a FRU switchover. At the Hardware View, right-click the
graphic representing the replacement assembly to open a menu, then choose
Switchover.
13. Perform one of the following to clear the system error (ERR) LED:
— If at the HAFM application, open the Hardware View and:
a.
Right-click the front panel bezel graphic (away from a FRU) to open
a menu.
b.
Click Clear System Error Light.
— If at an EWS interface:
a.
Click the Switch tab at the Operations panel. The Operations panel
displays with the Switch page open.
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...