Diagnostics
115
23
Inspect CTP card operational states at the Embedded Web Server interface.
Inspect the Status fields for both CTP cards.
Does the Status field display a
Failed
message for either CTP card?
NO
YES
↓
A CTP card failure is indicated. Go to
24
Inspect SBAR assembly operational states at the Embedded Web Server interface.
Inspect the Status fields for both assemblies.
Does the Status field display a
Failed
message for either SBAR assembly?
NO
YES
↓
An SBAR assembly failure is indicated. Go to
The director is operational. Exit MAP.
MAP 0600: UPM Card Failure and Link Incident Analysis
This MAP describes fault isolation for UPM cards, shortwave laser small form
factor pluggable (SFP) optical transceivers, and longwave laser SFP optical
transceivers; and for Fibre Channel link incidents. Failure indicators include:
■
One or more amber LEDs on the UPM card illuminate.
■
One or more emulated amber LEDs on a UPM card graphic at the Hardware
View illuminate.
■
A blinking red and yellow diamond (failed FRU indicator) displays over a
UPM card graphic or a yellow triangle (attention indicator) displays at the
alert panel of the HAFM main window, Hardware View, or Port Card
View.
■
An event code recorded at the Director 2/140 Event Log or the Embedded
Web Server Event Log.
■
A port operational state message or a
Failed
message associated with a
UPM card at the Embedded Web Server interface.
■
A link incident message recorded in the Link Incident Log or Port Properties
dialog box.
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...