Repair Information
168
Invalid
Attachment
On
Off
Yellow
Triangle
The director port has an invalid
attachment state if:
(1) a loopback plug is
connected to the port with no
diagnostic test running, or
(2) the port is cabled to another
port on the same director, or
(3) the port connection conflicts
with the configured port type.
Link Incident Off
Off
Yellow
Triangle
A link incident occurred on the
port. The alert symbol displays
at the Port Card View, Port List
View, and Hardware View.
Link Reset
Off
Off
Yellow
Triangle
The director and attached
device are performing a link
reset operation to recover the
link connection. This is a
transient state that should not
persist.
No Light
Off
Off
None
No signal (light) is received by
the director port. This is a
normal condition when there is
no cable attached to the port or
when the attached device is
powered off.
Not
Operational
Off
Off
Yellow
Triangle
The director port is receiving the
not operational sequence
(NOS) from an attached device.
Port Failure
Off
On
Red and
Yellow
Blinking
Diamond
The director port failed and
requires service.
Table 22: Port Operational States (Continued)
Port
State
Green
LED
Amber
LED
Alert
Symbol
Description
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...