Diagnostics
120
9
Does a blinking red and yellow diamond (failed FRU indicator) display over a
UPM card graphic at the Hardware View or display adjacent to a Fibre Channel
port graphic at the Port Card View?
NO
YES
↓
A port or UPM card failure is indicated. Go to
10
Did a Fibre Channel port or UPM card (all ports) fail a loopback test?
NO
YES
↓
11
Does a yellow triangle (attention indicator) display over a UPM card graphic at
the Hardware View or display adjacent to a port graphic at the Port Card View?
YES
NO
↓
12
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Port Card View, double-click the port graphic with the attention
indicator. The Port Properties dialog box displays.
2. Inspect the Operational State field at the Port Properties dialog box, and the
emulated green and amber LEDs adjacent to the port at the Port Card View.
3.
lists LED and port operational state combinations and associated
MAP 0600 (or other) steps that describe fault isolation procedures.