Diagnostics
113
16
An SBAR assembly is not recognized by director firmware because the firmware
version is not supported or the SBAR assembly failed. Advise the customer of the
problem and determine the correct firmware version to download from the HAFM
appliance.
Download the firmware (“
Download a Firmware Version to a Director
page 210). Perform the data collection procedure after the download.
Continue to the next step.
17
Did the firmware download solve the problem?
NO
YES
↓
The director is operational. Exit MAP.
An SBAR assembly failure is indicated. Go to
18
Is the Embedded Web Server interface operational?
NO
YES
↓
19
A
Page cannot be found, Unable to locate the server,
HTTP 404-file not found
, or other similar message displays. The
message indicates the Web browser PC cannot communicate with the director
because:
■
The director-to-PC Internet link could not be established.
■
AC power distribution in the director failed, or AC power was disconnected.
■
Both of the director’s CTP cards failed.
Continue to the next step.