Event Code Tables
354
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 411
Message:
Firmware fault.
Severity:
Major.
Explanation:
Firmware executing on the indicated CTP card encountered an unexpected
operating condition and dumped the operating state to FLASH memory for retrieval
and analysis. The dump file is automatically transferred from the director to the
HAFM appliance, where it is stored for retrieval through the data collection
procedure.
A non-disruptive failover to the backup CTP card occurs. When the dump and
subsequent IPL complete, the faulty CTP card reinitializes to become a the backup.
Action:
Perform the data collection procedure and return the backup CD to HP support
personnel.
Event Data:
Bytes 0 through 3 = fault identifier, least significant byte first.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 412
Message:
CTP watchdog timer reset.
Severity:
Informational.
Explanation:
The hardware watchdog timer expired and caused the CTP card to reset.
Action:
Perform the data collection procedure and return the backup CD to HP support
personnel.
Event Data:
Byte 0 = reset type as follows: 00 = task switch did not occur within approximately
one second,
01 = interrupt servicing blocked for more than approximately one second.
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...