Diagnostics
157
9
Perform one of the following:
■
If the appliance has standalone diagnostic test programs resident on the hard
drive, perform the diagnostics. Refer to supporting documentation shipped
with the appliance for instructions.
■
If the appliance does not have standalone diagnostic test programs resident on
fixed disk, go to
Did diagnostic test programs detect a problem?
NO
YES
↓
Refer to the supporting documentation shipped with the appliance for
instructions to resolve the problem. Exit MAP.
10
Reboot the HAFM appliance.
1. Choose Start > Shut Down. The Shut Down Windows dialog box displays.
2. Choose Shut down from the drop-down list and click OK to power off the
appliance.
3. Wait approximately 30 seconds and press the power (
) button on the liquid
crystal display (LCD) panel to power on the appliance and perform power-on
self-test (POST). During POST:
a.
The green LCD panel illuminates.
b. The green hard disk drive (HDD) LED blinks momentarily, and processor
speed and random-access memory information display momentarily at the
LCD panel.
c.
After a few seconds, the LCD panel displays a message, as shown in
d. Ignore the message. After ten seconds, the appliance performs the boot
sequence from the basic input/output system (BIOS). During the boot
sequence, the appliance performs additional POST tests and displays the
following operational information at the LCD panel:
— Host name.
— System date and time.
— LAN 1 and LAN 2 IP addresses.
— Fan 1, fan 2, fan 3, and fan 4 rotational speed.
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...