Diagnostics
117
4
Is fault isolation being performed at the director?
YES
NO
↓
Fault isolation is being performed at the HAFM appliance or
Embedded Web Server interface. Go to
5
Inspect the faceplates of UPM cards at the front of the director. Each card has an
amber LED (at the top of the card) that illuminates if the card fails or if any Fibre
Channel port fails.
Each card also has a bank of amber and green LEDs above the ports. Each LED
pair is associated with a corresponding port (for example, the top LED pair is
associated with the top port). The amber LED illuminates and the green LED
extinguishes if the port fails.
Are an amber port LED and the amber LED at the top of the UPM card
illuminated but not blinking (beaconing)?
YES
NO
↓
The director is operational, however a link incident or other problem
may have occurred. Perform fault isolation at the HAFM appliance.
Go to
6
A Fibre Channel port failed, and the SFP optical transceiver must be removed and
replaced (“
■
This procedure is concurrent and can be performed while director power is on.
586
Invalid primitive sequence received for current
link state.
Go to
800
High temperature warning (UPM card thermal
sensor).
Go to
801
Critically hot temperature warning (UPM card
thermal sensor).
Go to
802
UPM card shutdown due to thermal violation.
Go to
Table 12: MAP 0600: Event Codes (Continued)
Event Code
Explanation
Action
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...