background image

HP StorageWorks
Fabric OS 5.x
command reference guide

Part number: AA–RVHVB–TE

Second edition: September 2005

Summary of Contents for StorageWorks 2/64 - Core Switch

Page 1: ...HP StorageWorks Fabric OS 5 x command reference guide Part number AA RVHVB TE Second edition September 2005 ...

Page 2: ...ion which is protected by copyright No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Hewlett Packard The information is provided as is without warranty of any kind and is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such p...

Page 3: ...interface 18 Using this guide 19 2 Fabric OS commands 21 aaaConfig 22 agtCfgDefault 25 agtCfgSet 29 agtCfgShow 32 aliAdd 35 aliasDelete 37 aliasJoin 38 aliasPurge 40 aliasShow 41 aliCreate 42 aliDelete 44 aliRemove 45 aliShow 47 aptPolicy 49 authUtil 52 backplaneTest 54 backport 56 bannerSet 58 bannerShow 59 bcastShow 60 bladeBeacon 62 bladeDisable 63 bladeEnable 65 burninErrClear 67 burninErrShow...

Page 4: ...1 diagDisablePost 142 diagEnablePost 143 diagEnv 144 diagFailLimit 146 diagHelp 147 diagLoopId 148 diagModeShow 149 diagPost 151 diagRetry 152 diagSetBurnin 153 diagSetCycle 154 diagSetEsdMode 156 diagShow 157 diagShowTime 158 diagSkipTests 159 diagStatus 160 diagStopBurnin 161 dlsReset 162 dlsSet 163 dlsShow 164 dnsConfig 165 enclosureShow 167 errClear 168 errDelimiterSet 169 errDump 170 errFilte...

Page 5: ...4 ficoncupset 225 ficoncupshow 226 ficonHelp 228 ficonShow 230 filterTest 237 firmwareCommit 239 firmwareDownload 241 firmwareDownloadStatus 245 firmwareRestore 247 firmwareShow 248 fportTest 249 fruReplace 252 fspfShow 254 fwAlarmsFilterSet 257 fwAlarmsFilterShow 258 fwClassInit 259 fwConfigReload 260 fwConfigure 261 fwFruCfg 267 fwHelp 269 fwMailCfg 270 fwPortDetailShow 273 fwSamShow 276 fwSet 2...

Page 6: ...bShow 333 memShow 337 miniCycle 338 minisPropShow 344 msCapabilityShow 346 msConfigure 348 msPlatShow 350 msPlatShowDBCB 352 msPlClearDB 353 msPlMgmtActivate 354 msPlMgmtDeactivate 355 msTdDisable 356 msTdEnable 358 msTdReadConfig 359 myId 360 nbrStateShow 361 nbrStatsClear 362 nodeFind 365 nsAliasShow 368 nsAllShow 372 nscamShow 374 nsShow 377 nsZoneMember 382 passwd 386 pathInfo 388 pdShow 393 p...

Page 7: ...ault 448 portCfgEPort 449 portCfgGPort 450 portCfgISLMode 451 portCfgLongDistance 453 portCfgLPort 456 portCfgPersistentDisable 459 portCfgPersistentEnable 461 portCfgShow 463 portCfgSpeed 466 portCfgTrunkPort 467 portDebug 468 portDisable 469 portEnable 470 portErrShow 471 portFlagsShow 473 portLedTest 475 portLogClear 476 portLogConfigShow 477 portLogDump 478 portLogDumpPort 480 portLogEventShow...

Page 8: ...til 559 secDefineSize 563 secFabricShow 564 secFCSFailover 566 secGlobalShow 567 secHelp 568 secModeDisable 570 secModeEnable 571 secModeShow 577 secNonFcsPasswd 578 secPolicyAbort 579 secPolicyActivate 580 secPolicyAdd 581 secPolicyCreate 585 secPolicyDelete 589 secPolicyDump 592 secPolicyFCSMove 595 secPolicyRemove 597 secPolicySave 600 secPolicyShow 601 secStatsReset 603 secStatsShow 606 secTem...

Page 9: ...pportShowCfgShow 681 switchBeacon 682 switchCfgPersistentDisable 683 switchCfgPersistentEnable 684 switchCfgSpeed 685 switchCfgTrunk 686 switchDisable 687 switchEnable 688 switchName 689 switchReboot 690 switchShow 691 switchShutdown 694 switchStart 695 switchStatusPolicySet 696 switchStatusPolicyShow 698 switchStatusShow 700 switchUptime 702 syslogdFacility 703 syslogdIpAdd 704 syslogdIpRemove 70...

Page 10: ...h commands 769 ISL Trunking commands 769 Advanced Performance Monitoring commands 770 Secure Fabric OS commands 771 4 Exclusive primary FCS commands 773 Commands exclusive to the primary FCS 773 5 MUA based roles 777 switchAdmin Role Permissions 777 6 Control processor commands 787 Commands supported on the active CP 787 Commands supported on the standby CP 787 7 supportShow reference 789 supportS...

Page 11: ...fabric watch classes and areas 261 14 i command field descriptions 300 15 Object descriptions 319 16 lsdbShow display fields 333 17 portShow display fields 510 18 Default contributor values and status 696 19 Default contributor values and status 698 20 Zoning commands 767 21 QuickLoop fabric assist mode commands 768 22 Extended fabrics commands 769 23 Fabric watch commands 769 24 HP trunking comma...

Page 12: ...12 Contents ...

Page 13: ...teps To access current Fabric OS 5 x related documents 1 Locate the IT storage products section of the web page 2 Under Networked storage click SAN infrastructure 3 From the SAN Infrastructure web page locate the SAN Infrastucture products section 4 Click Fibre Channel Switches 5 Locate the B Series Fabric Enterprise Class section Click 4 256 SAN Director and 4 256 SAN Director power pack to acces...

Page 14: ...nvention Element Medium blue text Figure 1 Cross reference links and e mail addresses Medium blue underlined text http www hp com Web site addresses Bold font Key names Text typed into a GUI element such as into a box GUI elements that are clicked or selected such as menu and list items buttons and check boxes Italics font Text emphasis Monospace font File and directory names System output Code Te...

Page 15: ...bscriber s choice web site http www hp com go e updates Subscribing to this service provides you with e mail updates on the latest product enhancements newest versions of drivers and firmware documentation updates as well as instant access to numerous other product resources After signing up you can quickly locate your products by selecting Business support and then Storage under Product Category ...

Page 16: ...16 ...

Page 17: ... Each account has hard coded permissions that define roles whose privileges correspond to the account name In HP s Fabric OS 3 x and earlier multiple user access to a switch is limited Each switch enables only a single session per access method regardless of the user s access level Switches can however be accessed simultaneously from different connections for example through the command line inter...

Page 18: ...ge entire fabrics individual switches and ports from a standard workstation The entire suite of Fabric OS features and capabilities is available across an entire fabric from a single access point Selected commands must be issued from a sectelnet or SSH session as indicated in the command description in this manual Access is controlled by a switch level password for each access level The commands a...

Page 19: ...ion and management of the HP fabric on multiple levels Identification isolation and management of SAN events across every switch in the fabric Management switch licenses Using this guide This guide describes each command including a synopsis of its syntax and the users to which it is available and provides a description of command usage and behavior The same information is available to you on your...

Page 20: ...20 Fabric OS command line interface ...

Page 21: ...Fabric OS 5 x command reference guide 21 2 Fabric OS commands This chapter lists the Fabric OS commands It also shows their syntax and operands and provides examples of their usage ...

Page 22: ...ated options Without any specified action the command displays the usage Specify action as one of following The following are the options for the add and change actions aaaConfig show Displays the current AAA service configuration add server options Adds a RADIUS server to the configuration remove server Removes a RADIUS server from the configuration change server options Changes a RADIUS server c...

Page 23: ...Fabric OS 5 x command reference guide 23 The following provides a detailed description of each action type show List the current RADIUS servers along with their parameters ...

Page 24: ...rver to_position Move the specified server in the existing RADIUS configuration list from the current position to the specified new position This rearranges the order in which the specified RADIUS server is used radius on off Enable or disable the current RADIUS configuration for AAA services This is used to switch the primary AAA services between RADIUS and the switch local database To enable the...

Page 25: ...SNMP management station to receive a trap generated by the agent the administrator must configure a trap recipient to correspond to the IP address of the management station In addition the trap recipient must be able to pass the access control list ACL check Trap recipient severity level The trap severity level is associated with each trap recipient IP address The event trap level is in conjunctio...

Page 26: ...ighest privilege matched out of six entries is given to the access The ACL check is turned off when all six entries contain 0 0 0 0 NOTE When secure mode is enabled the access control list feature is incorporated into the WSNMP and RSNMP security policies Community strings can be changed on the primary FCS switch only and will propagate changes across the fabric Operands none Examples To reset the...

Page 27: ... 6 FibreChannel ro No trap recipient configured yet SNMP access list configuration Entry 0 Access host subnet area 192 168 64 0 rw Entry 1 No access host configured yet Entry 2 No access host configured yet Entry 3 No access host configured yet Entry 4 No access host configured yet Entry 5 No access host configured yet Are you sure yes y no n no y Committing configuration done agent configuration ...

Page 28: ... trap recipient configured yet Community 4 public ro No trap recipient configured yet Community 5 common ro No trap recipient configured yet Community 6 FibreChannel ro No trap recipient configured yet SNMP access list configuration Entry 0 No access host configured yet Entry 1 No access host configured yet Entry 2 No access host configured yet Entry 3 No access host configured yet Entry 4 No acce...

Page 29: ...rigEquipMfr Community 3 private Community 4 public Community 5 common Community 6 FibreChannel For an SNMP management station to receive a trap generated by the agent the administrator must configure a trap recipient to correspond to the IP address of the management station In addition the trap recipient must be able to pass the access control list ACL check agtCfgSet sysDescr The system switch de...

Page 30: ...2 168 64 0 enables access by any hosts that start with the specified octets The connecting host is enabled to set each host subnet area to be read write or read only The highest privilege matched out of six entries is given to the access The ACL check is turned off when all six entries contain 0 0 0 0 NOTE When secure mode is enabled the access control list feature is incorporated into the WSNMP a...

Page 31: ...192 168 1 26 Trap recipient Severity level 0 5 0 Community rw private Trap Recipient s IP address in dot notation 0 0 0 0 192 168 64 88 Trap recipient Severity level 0 5 0 1 Community ro public Trap Recipient s IP address in dot notation 0 0 0 0 Community ro common Trap Recipient s IP address in dot notation 0 0 0 0 Community ro FibreChannel Trap Recipient s IP address in dot notation 0 0 0 0 SNMP...

Page 32: ...on Community 6 FibreChannel For an SNMP management station to receive a trap generated by the agent the administrator must configure a trap recipient to correspond to the IP address of the management station In addition the trap recipient must be able to pass the access control list ACL check agtCfgShow sysDescr The system switch description The default value is Fibre Channel Switch sysLocation Th...

Page 33: ... write or read only The highest privilege matched out of six entries is given to the access The ACL check is turned off when all six entries contain 0 0 0 0 NOTE When secure mode is enabled the access control list feature is incorporated into the WSNMP and RSNMP security policies Community strings can be changed on the primary FCS switch only and will propagate changes across the fabric Operands n...

Page 34: ...ecipient configured yet Community 6 FibreChannel ro No trap recipient configured yet SNMP access list configuration Entry 0 Access host subnet area 192 168 64 0 rw Entry 1 No access host configured yet Entry 2 No access host configured yet Entry 3 No access host configured yet Entry 4 No access host configured yet Entry 5 No access host configured yet ...

Page 35: ...ctive an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following required operands Examples To add members to zone aliases array1 array2 and loop1 aliAdd aliName Specify the name of a zone alias in quotation marks member Specify a member or list of me...

Page 36: ...36 Fabric OS commands See also aliCreate aliDelete aliRemove aliShow ...

Page 37: ...g the local port Use the aliasShow command to show the existing groups with its corresponding N_Ports Operands The following aliasDelete argument is required Examples To delete a port from an existing group Exit status See also aliasJoin aliasShow fabricShow switchShow aliasDelete portID The port ID in its hexadecimal representation switch admin aliasdelete 0x19c00 aliasDelete succeeded 0 Successf...

Page 38: ...th the local switch Operands none Examples To create an alias group of N_Ports or to add N_Ports to an existing group aliasJoin switch admin aliasJoin aliasJoin To add ports to an existing or new multicast group Number of ports in the group 1 64 1 To set an authorization password yes y no n no no password Setting the authorization control Add control 0 by any 1 only itself 2 by creator 0 2 0 Del c...

Page 39: ...Fabric OS 5 x command reference guide 39 Exit status See also aliasDelete aliasPurge aliasShow fabricShow nsAllShow nsShow 0 Successful operation nonzero Indicates the operation has failed ...

Page 40: ...p Operands The following aliasPurge argument is required Examples To remove an alias group Exit status See also aliasJoin aliasShow fabricShow switchShow aliasPurge groupID It is the group ID in its hexadecimal representation switch admin aliasPurge 0xfffb00 aliasPurge succeeded 0 Successful operation nonzero Indicates the operation has failed ...

Page 41: ...played If there are multiple entries in the local alias group they are displayed Operands none Examples To display the entries in the local alias server Exit status See also fabricShow switchShow aliasShow switch admin aliasShow AliasID Creator Token rb type grptype qlfr Member List fffb00 fffffd 00 05 10 10000060 69800228 019c00 The Local Alias Server has 1 entry 0 Successful operation nonzero In...

Page 42: ... the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following operands aliCreate aliName Specify a name for th...

Page 43: ...guide 43 Examples To create a zone alias See also aliAdd aliDelete aliRemove aliShow switch admin alicreate array1 2 32 2 33 2 34 switch admin alicreate array2 21 00 00 20 37 0c 66 23 switch admin alicreate loop1 4 5 0x02 6 7 0xEF 5 4 ...

Page 44: ...switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following operand Examples To delete the zone alias array2 See also aliAdd aliCreate aliRemov...

Page 45: ...led using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following operands aliRemove aliName Specify the name of the zone alias to have members removed in quotation marks This operand is required member Specify a member or list of members to be removed from the alias in quotation marks separated by semi...

Page 46: ...mands Examples Remove a world wide name from array1 See also aliAdd aliCreate aliDelete aliShow switch admin aliremove array1 3 5 switch admin aliremove array1 21 00 00 20 37 0c 76 8c switch admin aliremove array1 0xEF ...

Page 47: ...ed all zone configuration information both defined and effective is displayed See cfgShow for a description of this display Examples To display all zone aliases beginning with arr aliShow pattern A POSIX style regular expression used to match zone alias names This operand must be enclosed in quotation marks Patterns can contain Question mark which is a placeholder for any single character Asterisk...

Page 48: ...48 Fabric OS commands See also aliAdd aliCreate aliDelete aliRemove ...

Page 49: ...gress port on which the frame was received Destination domain for the frame The chosen path remains the same if Dynamic Load Sharing DLS feature is not enabled If DLS is enabled then a different path may be chosen on a fabric event See dlsSet for the definition of a fabric event This policy may provide better ISL utilization when there is little or no oversubscription of the ISLs Note that static ...

Page 50: ...ID DID OXID parameters takes the same path unless there is a fabric event See dlsSet for the definition of a fabric event This policy does not support static routes DLS always is enabled and the DLS setting cannot change with this policy switch admin aptpolicy Current Policy 3 3 Default Policy 1 Port Based Routing Policy 2 Device Based Routing Policy 3 Exchange Based Routing Policy switch admin ap...

Page 51: ...Fabric OS 5 x command reference guide 51 See also dlsReset dlsSet dlsShow switchDisable ...

Page 52: ...ommand has the following operands authUtil show Displays local authentication configuration Modifies authentication configuration Values include set a Sets authentication protocol Specify fcap to set only FCAP authentication dhchap to set only DH CHAP authentication and all to set both FCAP and DH CHAP default When authentication is set to all implicit order is FCAP followed by DH CHAP for example...

Page 53: ...roups to be specified in auth negotiate in order of 0 1 2 3 and 4 See also portShow secAuthSecret switch admin authutil show AUTH TYPE HASH TYPE GROUP TYPE dhchap sha1 md5 0 1 2 3 4 switch admin authutil set a dhchap Authentication is set to dhchap switch admin authutil set a all Authentication is set to fcap dhchap switch admin authutil set g 3 DH Group was set to 3 switch admin authutil set g DH...

Page 54: ...ch 4 32 and 4 256 SAN Director which use the Condor ASIC Operands This command has the following operands backplaneTest slot number Specifies the slot on which the diagnostic operates The ports specified are relative to this slot number passcnt count Specifies the number of times to perform this test The default value is 1 payload value Specifies the byte size of the test frame payload The payload...

Page 55: ...TIMEOUT XMIT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also itemList switch admin backplanetest ports 1 16 18 20 payload 2048 verbose 1 Running backplanetest Test frame info for Backplane Connection Test of frames 1 sid data 0xfffffd did data 0xfffffd payload size 2048 bytes Test Complete backplanetest Pass 1 of 1 Duration ...

Page 56: ...th The test checks for CRC and ENC errors for each port used between the source and destination ports to help isolate failures It also checks that each member of every trunk group along the path has sent or received at least one frame Area routing between user ports is not tested Use of this command assumes that the same database is used for domain and area routes therefore domain results are indi...

Page 57: ...ault value is 0 which disables this mode This command normally sends bursts of frames from each port under test to every other port in the list With extonly mode set to 1 the command sends only one burst of frames to each port from each ASIC pair to ASIC pair link This tests all of the external connections with only K N frames instead of the N 2 frames required in all to all mode This mode is inte...

Page 58: ... characters If the banner text length exceeds the maximum allowed the software truncates the input To close the banner text string enter a period at the beginning of a new line Operands This command has the following operand Examples To set a new banner for a switch See also bannerShow bannerSet banner Specify a text string to be displayed when a user logs in If you enter the banner text using the...

Page 59: ...rshow Availability admin Description Use this command to display the contents of the banner Operands none Examples To display the banner for a switch See also bannerSet bannerShow switch admin bannershow Banner Do not log into this switch if you are not an authorized administrator ...

Page 60: ...t routing information for the ports is displayed as a set of hexadecimal bit maps Each bit in a bit map represents a port with the least significant bit in each row representing port 0 32 64 and so on For more information on reading hexadecimal bit maps see the HP StorageWorks Fabric OS 5 x administrator guide NOTE The output from this command varies depending on switch type Operands none Examples...

Page 61: ...the previous example from a switch with 128 ports the member ports consist of ports 7 13 42 84 85 and 86 The final Member Ports bit set represents the embedded port frames sent to be handled by firmware and is typically set See also portRouteShow ...

Page 62: ... disabled port for example is suppressed and only the beaconing pattern is displayed If a diagnostic frame based test such as portLoopbackTest crossPortTest or spinSilk is executed the two LED patterns are interwoven The diagnostic test flickers the LEDs green and the beaconing mode runs the LEDs amber The switchShow command can be used to display if the status of blade beaconing mode is on or off...

Page 63: ...t be disabled before making configuration changes or before running many of the diagnostic tests The blade does not need to be disabled before rebooting or powering off Observe and verify the disable process by watching the front panel LEDs change to slow flashing yellow as each port of the blade disables NOTE A blade cannot be disabled or enabled when the switch is disabled or when the blade itse...

Page 64: ...tch admin bladedisable 2 Blade 2 is being disabled Done switch admin slotshow Slot Blade Type ID Status 1 SW BLADE 2 ENABLED 2 SW BLADE 2 ENABLED User Ports Disabled 3 SW BLADE 2 ENABLED 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 SW BLADE 2 ENABLED 9 SW BLADE 2 ENABLED 10 SW BLADE 2 ENABLED ...

Page 65: ...mplete description of this process Observe and verify the enable process by watching the front panel LEDs change from slow flashing amber as each port enables The LEDs change to green for online ports unlighted for disconnected ports or amber for ports that do not initialize NOTE A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is disabled using slotOff fa...

Page 66: ...VACANT 10 UNKNOWN VACANT switch admin bladeenable 4 slBlade 4 is being enabled Done switch admin slotshow Slot Blade Type ID Status 1 SW BLADE 2 ENABLED 2 UNKNOWN VACANT 3 UNKNOWN VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT ...

Page 67: ... in the nonvolatile storage on the slot during burn in NOTE HP StorageWorks recommends running the burninErrClear command prior to running diagSetBurnin and diagSetCycle Operands This command has the following operand Examples To clear burn in errors from slot 2 See also burninErrShow burninErrClear slotNum A nonzero value that specifies the slot number from which to clear burn in errors switch ad...

Page 68: ...cription Use this command to display errors stored in the nonvolatile storage on the slot during burn in Operands This command has the following operand Examples To display burn in errors from slot 2 See also burninErrClear burninErrShow slotNum A nonzero value that specifies the slot number from which to display burn in errors switch admin burninErrShow 2 ...

Page 69: ...iagnostics daemon and the burn in scripts run A useful application of this command is to store errors on the local persistent error storage on which the error occurs This happens when the burn in level is other than 0 This preserves the errors prior to returning a board for service For multibladed products this is the independent blade and for fixed port count products this is the chassis persiste...

Page 70: ...s are optional Examples To display the burn in status for all slots To display the burn in status for slot 3 See also diagSetBurnin burninStatus slot slotnumber Optional specify to get the burn in status of a single slot If not specified all slots are displayed switch admin burninstatus Slot State Status Run Cmd TotCmds PID Script 1 ABORT PASS 3 18 41 916 burnin 2 ABORT PASS 3 18 41 920 burnin 3 A...

Page 71: ...anslated with the domain and area fields of the SID zeroed If a miss is expected when the walking 1 or walking 0 pattern is used the original SID in the frame transmitted is received unchanged NOTE This command cannot be executed on an enabled switch You must first disable the switch using the switchDisable command This command is supported on the SAN Switch 2 8V SAN Switch 2 16V SAN Switch 2 32 C...

Page 72: ...IAG CAMSID DIAG CAMSTAT DIAG CANTXMIT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest switch admin camtest txports 1 1 Running camtest Test Complete camtest Pass 1 of 1 Duration 0 hr 0 min 5 sec 0 0 5 14...

Page 73: ...ts If the done bit in each SRAM is not set within a time out period it reports the DIAG CMBISRTO If any of the SRAMs within the ASIC fails to map out the bad rows its fail bit is set and the DIAG CMBISRF error generated Data read write subtest The data write read subtest executes the address and data bus verifications by running a specified unique ramp pattern D to all SRAMs in all ASICs in the sw...

Page 74: ...r and interrupt bits of all ASICs 2 Write 64 bytes with bad parity to all ASICs at offset 0 3 Read each of the ASIC pairs at offset 0 and check that the error and interrupt bits are set 4 Repeat step 1 through step 3 for offset 1 through 10 Buffer number error subtest The forced bad buffer number error subtest verifies that the bad buffer number in the data packet can be detected and its error fla...

Page 75: ...offset to test Operands This command has the following operands slot slotnumber Specify the slot number on which the diagnostic will operate The ports specified will be relative to this slot number The default is set to 0 and designed to operate on fixed port count products passcnt count Specify the number of test passes to run By default the test runs one time datatype type Specify the type of da...

Page 76: ...IMEOUT Subtest 5 BAD_INT CM_ERR_PTN CM_ERR_TYPE TIMEOUT Subtest 6 BAD_INT CM_ERR_PTN CM_ERR_TYPE TIMEOUT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also camTest cmemRetentionTest cmiTest crossPortTest itemList switch admin centralmemorytest ports 1 0 1 15 Running centralmemorytest Test Complete centralmemorytest Pass 1 of 1 ...

Page 77: ...Fabric OS 5 x command reference guide 77 portLoopbackTest portRegTest spinSilk sramRetentionTest ...

Page 78: ...gle zone configuration that is currently in effect The devices that an initiator sees are based on this configuration The effective configuration is built when a specified zone configuration is enabled NOTE When security is enabled this command can be issued on any switch in the fabric Operands none Examples To display the effective zone configuration information See also cfgClear cfgDelete cfgRem...

Page 79: ...ome in effect an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following required operands Examples To add two new zones to the configuration Test_cfg See also cfgClear cfgCreate cfgDelete cfgDisable cfgEnable cfgAdd cfgName Specifies a name for the z...

Page 80: ...80 Fabric OS commands cfgRemove cfgSave cfgShow ...

Page 81: ...use the cfgDisable command to commit the transaction and then disable and clear the zone configuration in flash memory for all the switches in the fabric If no current zoning configuration exists use the cfgSave command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands none Examples To clear all zones and then clear flash memory cfgClear switch admi...

Page 82: ...82 Fabric OS commands See also cfgDisable cfgEnable cfgSave ...

Page 83: ...ration For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command See the zoneCreate command for more information on name and member specifications NOTE When security is enabled this command can be issued only from the primary FCS swi...

Page 84: ...84 Fabric OS commands See also cfgAdd cfgClear cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow ...

Page 85: ...oss switch reboots it must be saved to flash memory using the cfgSave command For the change to become in effect an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following operand Examples To delete a zone configuration See also cfgAdd cfgClear cfgCre...

Page 86: ...atile and flash memory If a transaction is open on a different switch in the fabric when this command is run the transaction on the other switch is automatically aborted A message is displayed on the other switches to indicate the aborting of the transaction NOTE When security is enabled this command can be issued only from the primary FCS switch Operands none Examples To disable the current zone ...

Page 87: ...ous configuration remains in effect If the build succeeds the new configuration replaces the previous configuration See the cfgShow command for a description of defined and current configurations NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following operand Examples To enable the zone configuration USA_cfg See also cfgClea...

Page 88: ...to flash memory using the cfgSave command For the change to become in effect an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands The following operands are required Examples To remove a zone from a configuration See also cfgAdd cfgClear cfgCreate cfgRemove cfgName Specify a ...

Page 89: ...Fabric OS 5 x command reference guide 89 cfgDelete cfgDisable cfgEnable cfgSave cfgShow cfgTransAbort cfgTransShow ...

Page 90: ...onfiguration is valid by performing the same tests as cfgEnable If the tests fail an error is displayed and the configuration is not saved Tests might fail if a configuration has been modified since the last cfgEnable This command ends and commits the current transaction If a transaction is open on a different switch in the fabric when this command is run the transaction on the other switch is aut...

Page 91: ...Fabric OS 5 x command reference guide 91 See also cfgAdd cfgClear cfgCreate cfgDelete cfgDisable cfgEnable cfgRemove cfgShow cfgTransAbort cfgTransShow ...

Page 92: ...s or aliases that are referenced but not defined or there might be duplicate members The defined configuration is the current state of the administrator input The effective configuration is the single zone configuration that is currently enabled The devices that an initiator sees in the fabric are based on this configuration The effective configuration is built when a specific zone configuration i...

Page 93: ...ay the contents of the transaction buffer the contents of the current transaction or specify 1 to display the contents of flash memory The default value is 0 switch admin cfgshow Test cfg Test1 Blue_zone cfg Test_cfg Red_zone Blue_zone switch admin cfgshow Defined configuration cfg USA1 Blue_zone cfg USA_cfg Red_zone Blue_zone zone Blue_zone 1 1 array1 1 2 array2 zone Red_zone 1 0 loop1 alias arra...

Page 94: ...94 Fabric OS commands See also cfgAdd cfgClear cfgCreate cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgTransAbort cfgTransShow ...

Page 95: ... size details of the defined configuration See also cfgSize Zone DB max size The upper limit for the defined configuration determined by the amount of flash memory available for storing the defined configuration Transaction size The size of the uncommitted defined configuration This value will be nonzero if the defined configuration is being modified by telnet API and so forth otherwise it is 0 Co...

Page 96: ...96 Fabric OS commands cfgShow ...

Page 97: ...ase restored to the state before the transaction was started If a transaction is open on a different switch in the fabric when this command is run the transaction on the other switch remains open and unaffected NOTE When security is enabled this command can be issued only from the primary FCS switch Operands This command has the following operand Examples To abort the current transaction See also ...

Page 98: ... aborted or not The transaction cannot be aborted if it is an internal zoning transaction NOTE When security is enabled this command can be issued only from the primary FCS switch Operands none Examples To display the current transaction See also cfgAdd cfgClear cfgCreate cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow cfgTransAbort cfgTransShow switch admin cfgtransshow There is no outst...

Page 99: ...switches blade ID 4 on slots 1 through 4 and 7 through 10 blade ID 5 on slots 5 and 6 3 Two 64 port switches blade ID 4 on slots 1 through 4 blade ID 2 on slots 7 through 10 blade ID 5 on slots 5 and 6 4 Two 64 port switches blade ID 2 on slots 1 through 4 blade ID 4 on slots 7 through 10 blade ID 5 on slots 5 and 6 5 One 256 port switch blade ID 17 18 on slots 1 through 4 and 7 through 10 blade I...

Page 100: ...nsition Operands The operands are as follows Examples To display the current configuration option on an HP StorageWorks SAN Director 2 128 and to change the option f If specified forces configuration changes without asking for confirmation or requesting a configuration upload option Specifies the new configuration option to apply to the chassis This operand is optional if omitted this command disp...

Page 101: ...e IDs and their marketing names switch admin chassisconfig 2 This will reboot all the CPs and the configuration data will be restored to factory defaults if moved between single and multiple domains This includes but are not limited to port swap routing zoning performance monitoring port config fabric watch management server time server snmp security fabric and other FabOs configuration parameters...

Page 102: ...nfiguration Server Name or IP Address host 192 168 79 240 User Name user ckonchad File Name config txt Password Upload complete Are you sure you want to continue Y N y Current Option changed to 2 Restoring switch 0 configuration to factory defaults done Telnet connection goes down at this point ...

Page 103: ... chassis Enter this command with no parameter to display the current name Enter this command with a name operand to set the chassis name Operands This command has the following operand Examples To change the chassis name to dilbert See also switchName chassisName name Specifies a new name for the chassis Chassis names can be up to 15 characters long and must begin with a letter The name must consi...

Page 104: ... SUPPLY SW BLADE switch CP BLADE control processor WWN world wide name or UNKNOWN Object number Slot nn for blades Unit nn for everything else If the FRU is part of an assembly a brief description in parentheses displays 3 FRU header version number Header Version x 4 Value to calculate the object s power consumption positive for power supplies and negative for power consumers Power Consume Factor ...

Page 105: ...Fabric OS 5 x command reference guide 105 Examples To display all FRUs for a switch ...

Page 106: ... Header Version 1 Power Consume Factor 40 Factory Part Num 60 0001604 02 Factory Serial Num FP00X600128 Manufacture Day 12 Month 6 Year 2001 Update Day 15 Month 7 Year 2001 Time Alive 61 days Time Awake 16 days ID 555 374757 Part Num 236 296 12350 Serial Num 2836542 Revision Num A 00 POWER SUPPLY Unit 2 Header Version 1 Power Consume Factor 1000 Factory Part Num 60 0001536 02 Factory Serial Num A0...

Page 107: ...nit 1 Header Version 1 Power Consume Factor 50 Factory Part Num 20 123456 12 Factory Serial Num B014934500 Manufacture Day 6 Month 7 Year 2001 Update Day 15 Month 7 Year 2001 Time Alive 88 days Time Awake 16 days ID 456 777888 Part Num 230 290 12370 output truncated ...

Page 108: ...pecified blade slot NOTE The output of this command is only for support use only Operands This command has the following operands Examples To display the port registers of a chip See also minisPropShow chipRegShow slotnumber chipnumber Specifies the index of the chip within the specified blade to display The default is set to 0 and designed to operate on fixed port count products filter Specifies ...

Page 109: ...mber Specify the slot number on which the diagnostic will operate The ports specified will be relative to this slot number The default is set to 0 and designed to operate on fixed port count products Specify the number of test passes to run By default the test will be run one time Specify the type of data pattern to use By default type 9 QUAD_RAMP is used For a complete list of supported data patt...

Page 110: ...stics and system error messages reference guide for more information See also camTest centralMemoryTest cmiTest crossPortTest dataTypeShow itemList portLoopbackTest spinSilk sramRetentionTest switch admin cmemretentiontest slot 3 Running cmemretentiontest Test Complete cmemretentiontest Pass 2 of 2 Duration 0 hr 2 min Duration 0 hr 2 min Duration 0 hr 2 min 13 sec 0 2 13 234 13 sec 0 2 13 234 13 s...

Page 111: ...is not supported on the 4 16 SAN Switch SAN Switch 4 32 and 4 256 SAN Director which use the Condor ASIC Options This command has the following options cmiTest slot slotnumber Specifies the slot number to test The default is set to 0 and designed to operate on fixed port count products passcnt count Specifies the number of test passes to run By default the test runs one time txports itemlist Speci...

Page 112: ...CMINOCAP DIAG CMISA1 DIAG INTNIL See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also camTest centralMemoryTest cmemRetentionTest crossPortTest itemList portLoopbackTest spinSilk sramRetentionTest switch admin cmitest txports 3 0 3 7 rxports 3 8 3 15 Running cmitest Test Complete cmitest Pass 1 of 1 Duration 0 hr 0 min 2 sec 0 0 ...

Page 113: ...ide name HP Advanced Zoning configuration Security parameters and policies User account passwords Switch PID format Ethernet link mode Some configuration parameters are cached by the system To avoid unexpected switch behavior reboot the system after executing this command NOTE See the configure command for more information on default values for configuration parameters This command cannot be execu...

Page 114: ...114 Fabric OS commands Examples To restore the system configuration to default values See also agtCfgDefault configure switchDisable switchEnable switch admin configdefault Committing Configuration done ...

Page 115: ...installed from the distribution media and enabled The FTP service is widely available on UNIX hosts but less so on Windows hosts The FTP server must be running before a download can occur Use p scp to securely download the file through an SSH connection Instead of entering a password on the command line SCP prompts you for the password if necessary The SSH service is available on both UNIX and Win...

Page 116: ... added to the current switch configuration This enables you to change a single configuration variable by downloading a file with a single line All other variables remain unchanged The R_A_TOV E_D_TOV WAN_TOV and MAX_HOPS configuration parameters are interrelated Assigning a specific value to one or more of these parameters might change the range of allowed values that can be assigned to the other ...

Page 117: ...s for example jdoe This user name is used to gain access to the host system file Specifies the file name in quotation marks for example config txt Absolute path names might be specified using a forward slash Relative path names search for the file in the user s home directory on UNIX hosts and in the directory on which the FTP server is running on Windows hosts passwd Specifies the password for th...

Page 118: ...s configShow filter Specify a text string in quotation marks that limits the output of the command to only those entries that contain the text string switch admin configshow diag postDisable 0 fabric domain 1 fabric ops BBCredit 16 fabric ops E_D_TOV 2000 fabric ops R_A_TOV 10000 fabric ops dataFieldSize 2112 fabric ops max_hops 7 fabric ops mode fcpProbeDisable 0 fabric ops mode isolate 0 fabric ...

Page 119: ...censeShow syslogdIpShow switch admin configshow diag postDisable 0 fabric domain 1 fabric ops vc linkCtrl 0 fabric ops vc multicast 7 fabric ops wan_tov 0 fc4 fcIp address 192 168 65 62 fc4 fcIp mask 255 255 255 0 fcAL fanFrameDisable 0 fcAL useAltBBCredit 0 lcdContrast 128 licenseKey none rpc rstatd 1 rpc rusersd 1 ...

Page 120: ...on both UNIX and Windows hosts If the command is entered without operands it becomes interactive and prompts the user for input The upload might fail for the following reasons The host name is not known to the switch The host IP address cannot be contacted The user does not have permission on the host The user runs a script that prints something at login The FTP server is not running on the host T...

Page 121: ...sing account jdoe and file config txt To upload the same configuration file using SCP To upload the configuration file interactively host Specify a host name or IP address in quotation marks for example citadel or 192 168 1 48 The configuration file is downloaded from this host system user Specify a user name in quotation marks for example jdoe This user name is used to gain access to the host fil...

Page 122: ...122 Fabric OS commands See also configDefault configDownload configShow configure ...

Page 123: ...brackets Use the following options to control input Switch fabric settings There are several settings that control the overall behavior and operation of the fabric Some of these such as the domain are assigned automatically by the fabric and might differ from one switch to another in the fabric Other parameters such as the BB credit can be changed for specific applications or operating environment...

Page 124: ...The range of valid values varies depending on the switch model and other system parameter settings R_A_TOV The resource allocation time out value R_A_TOV is displayed in milliseconds This variable works with the variable E_D_TOV to determine switch actions when presented with an error condition Allocated circuit resources with detected errors are not released until the time value has expired If th...

Page 125: ... sequences When there are such devices attached to the fabric sequence level switching should be enabled Disable Device Probing When disable device probing is set to 1 devices that do not register with the name server are not present in the name server data base Set this mode only if the switch N_Port discovery process PLOGI PRLI INQUIRY causes an attached device to fail Suppress Class F Traffic W...

Page 126: ...B Credit The buffer to buffer BB credit represents the number of buffers available to attached devices for frame receipt The range of allowed values varies depending on other system settings Insistent Domain ID mode This mode enables a flag for the domain ID so that the current domain setting for the switch is insistent that is remains the same over switch reboots power cycles CP failovers firmwar...

Page 127: ...switch IP address or name change 1 Enabled Domain RSCN is sent to the end device for the switch IP address or name change Table 8 Configure command arbitrated loop settings Field Default Range Send FAN frames 1 0 or 1 Enable CLOSE on OPEN received 4 0 to 4 Always send RSCN 0 0 or 1 Send FAN frames Specifies that fabric address notification FAN frames be sent to public loop devices to notify them o...

Page 128: ...and RSYSINFO commands to retrieve the information See your local system documentation for the appropriate usage of the these or equivalent commands rusersd Dynamically enables or disables a server that returns information about the user logged into the system through remote procedure calls RPC The information returned includes user login name system name login protocol or type login time idle time...

Page 129: ...s must not be enabled before setting SSL attributes correctly Operands none SNMP SNMP Security Level number 0 0 1 2 cfgload Secure Config Upload and Download boolean off on off Table 10 Configurable application attributes continued Application File Type Default Range ...

Page 130: ... Per frame Route Priority 0 1 0 BB credit 1 16 16 Insistent Domain ID Mode yes y no n no Virtual Channel parameters yes y no n no yes VC Priority 2 2 3 2 VC Priority 3 2 3 2 VC Priority 4 2 3 2 VC Priority 5 2 3 2 VC Priority 6 2 3 3 VC Priority 7 2 3 3 Switch Operating Mode yes y no n no yes Interoperability Mode 0 1 0 Zoning Operation parameters yes y no n no yes Disable NodeName Zone Checking 0...

Page 131: ...d FAN frames 0 1 1 Enable CLOSE on OPEN received 0 1 0 Always send RSCN 0 1 0 Do Not Allow AL_PA 0x00 0 1 0 System services yes y no n no yes rstatd on off off rusersd on off off telnetd on off on Portlog events enable yes y no n no yes start a switch start or re start event on off on disable a port is disabled on off on enable a port is enabled on off on ioctl a port I O control is executed on of...

Page 132: ...to a copper port For best coverage connected ports should be from different ASICs For example Ports 0 through 3 belong to ASIC 0 ports 4 through 7 belong to ASIC 1 and so forth A connection from port 0 to port 15 exercises the transmit path between ASICs A connection from port 0 to port 3 tests only the internal transmit path in ASIC 0 Only one frame is transmitted and received at any one time The...

Page 133: ...disabled prior to executing the crossPortTest command all ports are assumed to be cable loopbacked to different ports in the same switch If one or more ports are not connected the test aborts NOTE All ports must be connected using loopback plugs or loopback cables for this test to run correctly in offline mode The test determines which port is connected to which port transmitting frames If any por...

Page 134: ...ports speed to AN set all odd ports speed to 1 Gb s 4 Set all even ports speed to AN set all odd ports speed to 2 Gb s 5 Set all odd ports speed to AN set all even ports speed to 1 Gb s 6 Set all odd ports speed to AN set all even ports speed to 2 Gb s For lb_mode set to 2 3 the following speed modes are available to test FIFO underrun 3 5 Set all even ports speed to 2 Gb s set all odd ports speed...

Page 135: ...Fabric OS 5 x command reference guide 135 cmemRetentionTest cmiTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest ...

Page 136: ... 00000000 BYTE_NOT 4 00 ff 00 ff 00 ff 00 ff 00 ff 00 ff 00 ff 00 ff WORD_NOT 5 0000 ffff 0000 ffff 0000 ffff 0000 ffff QUAD_NOT 6 00000000 ffffffff 00000000 ffffffff BYTE_RAMP 7 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f WORD_RAMP 8 0000 0001 0002 0003 0004 0005 0006 0007 QUAD_RAMP 9 00000000 00000001 00000002 00000003 BYTE_LFSR 10 69 01 02 05 0b 17 2f 5e bd 7b f6 ec d8 b0 60 c0 RANDOM 11 55...

Page 137: ...ade only on the primary FCS switch and distributed to the fabric It might take up to 64 seconds for the switches in the fabric to be synchronized If the switches in the fabric are 4 1 x 3 1 x or 2 6 x or higher this command sets date and time for all switches in the fabric If secure mode is disabled a change in date and time to one switch is forwarded to the principal switch and distributes to the...

Page 138: ...played will be in the range 1970 1999 For example if you enter 80 for yy then the year displayed will be 1980 Operands This command has the following operand Examples To display the current date and time and then modify it See also errShow ficoncupset ficoncupshow portLogShow tsClockServer tsTimeZone upTime newdate Specify the new date and time in quotation marks This operand is optional switch ad...

Page 139: ...f the specified module If no module name is specified displays debug and verbosity levels of all modules Operands This command has the following operands Examples To display information about a specific module named NS See also setDbg dbgShow module_name Specify the name of the module for which you want to view the debug and verbosity levels Module names are case sensitive This operand is optional...

Page 140: ...es To clear the diag software flag See also none diagClearError slot slotnumber Specify the slot to clear the diagnostics failure status The default is set to 0 and designed to operate on fixed port count products all If specified all blades clear If no operand is specified the default is to clear all bad port flags switch admin diagclearerror 1 0x1bcb fabos Switch 0 Error DIAG CLEARERR 3 Pt5 Sl1 ...

Page 141: ...commandshow bladepropshow display blade properties chippropshow display chip properties chipregshow display contents of port registers datatypeshow display available diagnostic data types diagcommandshow display diagnostic command descriptions diaghelp display diagnostic command descriptions diagmodeshow display diagnostic mode configuration diagoktorun check to see if it is ok to run a diagnostic...

Page 142: ...disable POST A reboot is not required for this command to take effect NOTE This command disables POST on both Core Switch 2 64 logical switches Operands none Examples To disable the POST during future powerons See also diagEnablePost diagDisablePost switch admin diagdisablepost Config update Succeeded Diagnostic POST is now disabled ...

Page 143: ...quired for this command to take effect POST includes two phases POST Phase I mainly tests hardware and POST Phase II tests system functionality NOTE This command disables POST on both Core Switch 2 64 logical switches Operands none Examples To enable the POST during future power ons See also diagDisablePost diagEnablePost switch admin diagenablepost Config update Succeeded Diagnostic POST is now e...

Page 144: ...ist of the diagEnv commands use diagdebughelp Each of these commands is an alias that evaluates the output of diagenv to set the diagnostic parameter for the current shell For example the following alias is created to implement diagsetdebug function diagsetdebug eval diagenv write USR_DEBUG These aliases are created by diagEnv as well by including the following command in the shell start up script...

Page 145: ... display the values of the diagnostic parameters See also none switch admin diagshowusr Name Environment Value USR_DILATION DIAG_USR_DLY_DILATION 1 USR_MEMDLY DIAG_USR_MEMDLY 10 USR_SEED DIAG_USR_SEED 0x0 USR_SPECIAL DIAG_USR_SPECIAL 0x0 output truncated ...

Page 146: ...lLimit The new fail limit becomes active as soon as this command is executed it does not require a reboot to take effect Operands This command has the following operands If no operand is specified the current value is displayed Examples To change the fail limit from 1 to 5 See also none diagFailLimit limit Specify the number of failures before a diagnostic test aborts The limit value must be 1 or ...

Page 147: ...perands This command has the following operand Examples To display diagnostic command information See also none diagHelp command Specify a command name to display more detailed information switch admin diaghelp bladepropshow display blade properties chippropshow display chip properties chipregshow display contents of port registers datatypeshow display available diagnostic data types diagcommandsh...

Page 148: ...s active as soon as this command is executed it does not require a reboot to take effect The actual behavior of diagLoopId depends on the test methods that use it NOTE Currently no FL mode tests exist Operands This command has the following optional operands If no operand is specified the current value is displayed Examples To display the loop ID Notes Currently no FL_Port mode tests exist diagLoo...

Page 149: ...f the specific variables not on their exact positions in the output Earlier versions of this command listed diag mode burnin nExec instead of Burnin nExec and listed diag mode burnin nExec instead of Burnin passnum Operands none Examples To display the diagnostic mode diagModeShow switch admin diagModeShow diag mode parameters saved in flash diag mode burnin 0 diag mode burnin level 0 diag mode bu...

Page 150: ...150 Fabric OS commands See also burninLevel setEsdMode setGbicMode setSplbMode ...

Page 151: ...m to inhibit testing of switch blades when the system is first powered on or a new blade is added NOTE To enable or disable diagnostic POST the recommended method is to use diagEnablePost and diagDisablePost Operands This command has the following optional operands If no operand is specified the current value is displayed Examples To enable and then disable the POST test See also diagDisablePost d...

Page 152: ...d is executed it does not require a reboot to take effect Retry mode modifies the behavior of the diagnostic test methods power on self test POST and burn in scripts The exact behavior depends on the tests and scripts that are run Operands This command has the following optional operands If no operand is specified the current value is displayed Examples To view the current retry mode value diagRet...

Page 153: ... to take effect NOTE Boards must be installed prior to running this command and diagSetCycle must be run prior to diagSetBurnin if you want to use both commands NOTE HP StorageWorks recommends running the burninErrClear command prior to running diagSetBurnin and diagSetCycle Operands This command has the following operands Examples To set the burn in script and mode See also burninErrShow diagSetC...

Page 154: ...ied the current value is left unchanged If a new value is entered its value is updated and stored in the configuration database for that blade type This command does not require a reboot to take effect NOTE HP StorageWorks recommends running the burninErrClear command prior to running diagSetBurnin and diagSetCycle Operands This command has the following operands diagSetCycle script Specify a scri...

Page 155: ...etcycle switchburnin sh show CURRENT KEYWORD DEFAULT 1 number_of_runs 1 2 vib 2 10 thermal 10 BURNIN label BURNIN 1 tbr_passes 1 1 prt_on 1 1 cntmem_on 1 1 cmi_on 1 1 retention_on 1 1 cam_on 1 50 flt_passes 50 25 sta_passes 25 100 plb_nframes 100 50 txd_nframes 50 200 xpt_nframes 200 20 bpt_nframes 20 50 slk_nmegs 50 30 bpt_all_nframes 30 50 slk_all_nmegs 50 ...

Page 156: ... ESD mode modifies the behavior of the diagnostic test methods and post scripts The exact behavior varies but most commonly consists of disabling the ports defined when spinSilk or other functional tests are run for ESD or EMI testing purposes Operands This command has the following operands Examples See also spinSilk diagSetEsdMode mode Specify 1 to enable ESD mode 0 to disable ESD mode This oper...

Page 157: ...xed port count products By default this command displays all user ports in the system uports itemlist Specify a list of user ports to display This operand is optional bports itemlist Specify a list of blade ports to display This operand is optional use_bports value If this value is not 0 the diagnostics status for the blade ports specified in use_bports displays otherwise the user ports specified ...

Page 158: ...fect Show time mode when enabled causes each test to display elapsed time messages It is normally used during burn in and for test method debugging NOTE diagsetshowtime is an alias of diagshowtime Operands This command has the following optional operands If no operand is specified the current value is displayed Examples To enable show time mode diagShowTime mode Specify 1 or any nonzero value to e...

Page 159: ...es not require a reboot to take effect The skip test flags are used to skip the execution of certain POSTs that might prove hazardous to normal switch operation The exact use of this flag is determined by the POST scripts and the specific test methods used Operands This command has the following operands If no operand is specified the current value is displayed Examples To display the current skip...

Page 160: ...as the following optional operand Examples To display currently running diagnostic tests diagStatus slotnumber Specifies the slot to display If omitted all blades in the system are assumed switch admin diagstatus Diagnostic status for slot 1 Diag executing NONE Diagnostic status for slot 2 Diag executing NONE Diagnostic status for slot 3 Diag executing NONE Diagnostic status for slot 4 Diag execut...

Page 161: ... Specify the slot to stop burn in If no slot is specified this command executes on all slots in the logical switch This operand is optional switch admin diagstopburnin slot 1 No burn in script active on slot 1 1 burninErrShow output 0x1eea fabos Dec 19 14 42 18 Switch 0 Error DIAG MANUAL1 1 1 Starting switchess Err 0140042 0100 101 000 001 24 37 0xc84 fabos Dec 20 08 57 27 Switch 0 Error DIAG MANU...

Page 162: ...ng NOTE This command should be used only if devices connected to the fabric cannot handle occasional routing changes correctly DLS is not supported in certain routing policies See aptPolicy for more information on routing policies Operands none Examples To disable the dynamic load sharing option See also aptPolicy dlsSet dlsShow dlsReset switch admin dlsreset Committing configuration done switch a...

Page 163: ... fabric is defined as an E_Port going up or down or an Fx_Port going up or down During load sharing recomputation existing routes might be moved to maintain optimal balance This can cause momentary frame loss along these routes In contrast if DLS is turned off using dlsReset load sharing calculations are used only to place new routes Once placed existing routes are never moved from one output E_Po...

Page 164: ...description of load sharing Operands none Examples To display the current DLS option setting See also dlsSet dlsReset dlsShow DLS is set The DLS option is turned on Load sharing is reconfigured with every change in the fabric and existing routes can be moved to maintain optimal balance DLS is not set The DLS option is turned off Once placed existing routes are never moved to maintain optimal balan...

Page 165: ...es To set the DNS parameters for the system dnsConfig switch admin dnsconfig Enter option 1 Display Domain Name Service DNS configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item 1 4 4 2 Enter Domain Name domain com Enter Name Server IP address in dot notation 123 123 123 123 Enter Name Server IP address in dot notation 123 123 123 124 DNS parameters saved successfu...

Page 166: ...166 Fabric OS commands See also configDownload configUpload firmwareDownload ipAddrSet ipAddrShow ...

Page 167: ...the enclosure interface to which the switch is attached Operands This command has the following operands Examples To display the identifier of the enclosure interface to which the switch is attached See also none enclosureShow attribute Attribute of the enclosure to display id Displays the vendor specific enclosure identifier modelname Displays the vendor specific enclosure model name slotid Displ...

Page 168: ...control processor CP Synopsis errclear Availability admin Description Use this command to clear all internal and external error log messages for all switch instances on this CP Operands none Examples To clear the error log messages See also errDump errShow errClear switch admin errclear ...

Page 169: ...guration These delimiters are stored persistently Operands This command has the following optional operands Examples To display the start and end delimiter To change the start and end delimiter with sample output See also errDump errFilterSet errShow errDelimiterSet s start_delimiter_string Specifies the alphanumeric string for the start delimiter up to 10 characters are allowed e end_delimiter_st...

Page 170: ...age Security audit flag Security audit logged AUDIT displays in the field Severity Severity of the message Valid values include INFO WARNING ERROR and CRITICAL Switch name Switch name for the generator of this message or chassis Message Message body End delimiter Delimiter string for the end of a message s switch_instance Specifies to display messages only from one switch instance Valid values are...

Page 171: ...Fabric OS 5 x command reference guide 171 See also errDelimiterSet errFilterSet errShow ...

Page 172: ...y in use Operands This command has the following operands Examples To display the current filter settings To set the filter severity level for the console See also errDump errModuleShow errFilterSet d destination Specifies the destination to set the filter The console string is the only valid value at this time v severity Specifies the minimum severity of the message to pass through the filter Val...

Page 173: ...mmand reference guide 173 Displays all the defined error log modules Synopsis errmoduleshow Availability user Description Use this command to display a list of all defined error log modules Operands none errModuleShow ...

Page 174: ...defined error log modules See also errDump errShow switch user errmoduleshow KT UT TRCE KTRC LOG CDR BLPU PISP PIXE EGR BL PIC PS RTE AS AUTH BLDE BLM BPRT CER CFLD CFMN CHPS CONF CPT DIAG EM ERRL FABR FABS FCIU FCMC FCPD FCPH FICU FILB FKLB output truncated ...

Page 175: ...Fabric OS 5 x command reference guide 175 ...

Page 176: ...p Timestamp for the message Message ID Message identifier External sequence number Sequence number for the message Security audit flag Security audit logged AUDIT displays in the field Severity Severity of the message Valid values include INFO WARNING ERROR and CRITICAL Switch name Switch name for the generator of this message or chassis Message Message body End delimiter Delimiter string for the ...

Page 177: ...er errshow Version 4 4 0 2004 07 14 22 24 08 HAMK 1003 1 INFO switch1 Heartbeat up Type CR to continue Q CR to stop 2004 07 14 22 24 47 FSSM 1002 2 INFO switchChassis HA State is in sync Type CR to continue Q CR to stop 2004 07 14 22 25 29 SEC 1192 3 INFO switch2 Security violation Login failure attempt via SERIAL Type CR to continue Q CR to stop ...

Page 178: ... telnet rlogin or serial port session Telnet and rlogin connections are closed the serial port returns to the login prompt The exit command is an accepted synonym for logout as is pressing Ctrl D at the beginning of a line Operands none Examples To exit from a shell session See also logout exit switch admin exit Connection to host lost ...

Page 179: ...fabPortShow Port Displays the port number State The state of the port P0 Port Offline P1 Port Online P2 ELP ACC Received P3 Link Reset Done I0 Trunk Initiator EMT Sent I1 Trunk Initiator ETP ACC Received I2 Trunk Initiator ETP Sent I3 Trunk Initiator Link Reset T0 Trunk Target EMT Received T1 Trunk Target ETP Received T2 Trunk Target Link Reset LD Dynamic long distance ECP sent or received T3 Trun...

Page 180: ... received an ELP 0x00080000 Port received an ELP RJT 0x00100000 LR pending due to ELP RJT rcv 0x00200000 Received a DIA on this port 0x00400000 Port is the EMT Initiator 0x00800000 Security violation 0x01000000 Security incompatibility 0x02000000 Rcv a DIA ACC 0x040000000 Port is security authenticating 0x080000000 ECP RJT or retires exceeded 0x100000000 Segmented due to duplicated WWN 0x200000000...

Page 181: ...splay fabric port information See also portShow switch admin fabportshow 4 14 Fabric Port Information Port 62 State P3 List 0x10068418 List Count 0 Flags 0x280120 nbrWWN 10 00 00 60 69 80 06 cf red_ports 10 11 62 63 Open commands pending No commands pending ...

Page 182: ...change Link Parameters ELP Exchange Link Parameters HA_EFP Exchange Fabric Parameters DIA Domain Identifier Assigned RDI Request Domain Identifier BF Build Fabric RSCN Remote State Change Notification FWD Fabric Controller Forward EMT Fabric Controller Mark Timestamp ETP Fabric Controller Trunk Parameters RAID Return Address Identifier GAID Get Address Identifier INQ Inquiry Command ELP_TMR Used i...

Page 183: ...ommands See also fabStatsShow switch user fabretryshow E_Ports SW_ISL 21 31 40 44 ELP 0 0 0 0 EFP 0 1 0 0 HA_EFP 0 0 0 0 DIA 0 0 0 0 RDI 0 0 0 0 BF 0 0 0 0 RSCN 0 0 0 0 FWD 0 0 0 0 EMT 0 0 0 0 ETP 0 0 0 0 RAID 0 0 0 0 GAID 0 0 0 0 INQ 0 0 0 0 ELP_TMR 0 0 0 0 GRE 0 0 0 0 ECP 0 0 0 0 FWN 0 0 0 0 ...

Page 184: ...le enable or resize the fabric log Operands This command has the following operands fabricLog s show Displays fabric log all users c clear Clears fabric log d disable Disables fabric log By default the fabric log is enabled e enable Enables fabric log r size resize size Changes the maximum number of log entries The given size has to be at least 2 and a power of 2 otherwise the command fails ...

Page 185: ...NA NA NA 11957 65 SCN Port Online F2 P0 F2 P1 21 NA 11957 69 ELP Send F2 P1 F2 P1 21 0x277 11957 69 SCN Port Online F2 P0 F2 P1 44 NA 11957 75 ELP Send F2 P1 F2 P1 44 0x279 11957 77 ELP Receive F2 P1 F2 P1 44 0x277 11957 78 ELP Sending ACC F2 P1 F2 P2 44 0x277 11957 82 ELP Receive F2 P1 F2 P1 21 0x279 11957 83 ELP Sending ACC F2 P1 F2 P2 21 0x279 11957 87 ELP ACC Receive F2 P2 F2 P2 21 0x277 switc...

Page 186: ...elected as the principal switch a small selection of switches should be connected together first followed by the addition of the rest of the fabric Operands This command has the following operands Examples To display the current mode setting To disable the principal selection mode setting To enable the principal selection mode setting fabricPrincipal f Specify the f option to force a fabric rebuil...

Page 187: ...5 x command reference guide 187 To enable the principal selection mode setting and force fabric rebuild See also fabricShow switch admin fabricprincipal f 1 Principal Selection Mode enabled Forcing fabric rebuild ...

Page 188: ...f the switches are configured to run IP over Fibre Channel See also switchShow fabricShow Switch ID The switch Domain_ID and embedded port D_ID world wide name The switch WWN Enet IP Addr The switch Ethernet IP address FC IP Addr The switch FC IP address Name The switch symbolic name An arrow indicates the principal switch switch admin fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Na...

Page 189: ... Online F2 NA F2 NA NA NA 11955 657 Start 2 F_S_TOV Timer F2 NA F2 NA NA NA 11955 657 Start 60 F_S_TOV Timer F2 NA F2 NA NA NA 11955 669 RSCN Rcv addr 0x3000000 F2 NA F2 NA NA NA 11957 65 SCN Port Online F2 P0 F2 P1 21 NA 11957 69 ELP Send F2 P1 F2 P1 21 0x277 11957 69 SCN Port Online F2 P0 F2 P1 44 NA 11957 75 ELP Send F2 P1 F2 P1 44 0x279 11957 77 ELP Receive F2 P1 F2 P1 44 0x277 11957 78 ELP Se...

Page 190: ... NA F2 NA NA NA 11955 669 RSCN Rcv addr 0x3000000 F2 NA F2 NA NA NA 11957 65 SCN Port Online F2 P0 F2 P1 21 NA 11957 69 ELP Send F2 P1 F2 P1 21 0x277 11957 69 SCN Port Online F2 P0 F2 P1 44 NA 11957 75 ELP Send F2 P1 F2 P1 44 0x279 11957 77 ELP Receive F2 P1 F2 P1 44 0x277 11957 78 ELP Sending ACC F2 P1 F2 P2 44 0x277 11957 82 ELP Receive F2 P1 F2 P1 21 0x279 11957 83 ELP Sending ACC F2 P1 F2 P2 2...

Page 191: ...Fabric OS 5 x command reference guide 191 See also fabricLog fabStateClear fabStateShow ...

Page 192: ...ynopsis fabstateshow Availability all users Description Use this command to display the queue of fabric state information logged by the fabric NOTE This command is obsoleted by fabricLog s Operands none Examples To display the fabric state information fabStateShow ...

Page 193: ...LP Sending ACC F2 P1 F2 P2 21 0x279 11957 87 ELP ACC Receive F2 P2 F2 P2 21 0x277 11957 92 ELP ACC Receive F2 P2 F2 P2 44 0x279 11957 94 SCN AC_PORT F2 P2 F2 P3 44 NA 11957 99 SCN AC_PORT F2 P2 F2 P3 21 NA 11957 106 SCN AC_PORT F2 P3 F2 P3 21 NA 11957 106 SCN AC_PORT F2 P3 F2 P3 44 NA 11957 364 SCN Port Online F2 P0 F2 P1 31 NA 11957 366 ELP Send F2 P1 F2 P1 31 0x27b 11957 382 ELP ACC Receive F2 P...

Page 194: ...ears as follows Number of times a switch domain ID has been forcibly changed Number of E_Port offline transitions Number of fabric reconfigurations Number of fabric segmentations due to Loopback Incompatibility Overlap Zoning E_Port segment Licensing Disabling E_Port Platform DB Security incompatibility Security violation ECP error Duplicate WWN E_Port isolated Operands none fabStatsShow ...

Page 195: ...fabstatsshow Description Count Domain ID forcibly changed 0 E_Port offline transitions 0 Reconfigurations 1 Segmentations due to Loopback 6 Incompatibility 0 Overlap 0 Zoning 0 E_Port Segment 0 Licensing 0 Disabled E_Port 0 Platform DB 0 Sec Incompatibility 0 Sec Violation 0 ECP Error 0 Duplicate WWN 0 Eport Isolated 0 ...

Page 196: ...isplay fabric switch state structure fabSwitchShow switch admin fabswitchshow Fabric Switch State Structure Information State D0 Stage warm done Rdi Receive Timer 0x10069400 IDLE STATE Unconfirmed Sw Timer 0x10069508 IDLE STATE NTP Timer 0x100695b8 IDLE STATE ME Timer 0x10069610 IDLE STATE Principal Domain 2 Upstream Port 64 Principal Wwn 10 00 00 60 69 80 06 ce Principal Priority 0x2 Flags 0x40 m...

Page 197: ...t 2 FWN frames pending 0 test check point No check point set fabric license TRUE fabric EFP version 7 last message 20 30 29 826 Snd inquiry 4 D0 NA D0 NA NA NA NTP ports online RSCN domain recovery list no domain RSCN s to recover reachable domains 1 3 4 3 domains reachable Ports used for EFP BF DIA flood output truncated ...

Page 198: ... command is not available on nonbladed systems except for the HP StorageWorks SAN Switch 4 32 Operands This command has the following operand Examples To disable a fan unit See also fanEnable fanShow fanDisable unit Specify the fan s unit number to disable View the fan unit numbers using the fanShow command This operand is required switch admin fandisable 1 Fan unit 1 has been disabled ...

Page 199: ...sabled using the fanDisable command NOTE This command is not available on nonbladed systems except for the StorageWorks SAN Switch 4 32 Operands This command has the following operand Examples To enable a fan unit See also fanDisable fanShow fanEnable unit Specify the fan s unit number to enable View the fan unit numbers using the fanShow command This operand is required switch admin fanenable 1 F...

Page 200: ...les To display information on the fans in the system See also chassisShow fanDisable fanEnable psShow fanShow OK Fan is functioning correctly absent Fan is not present below minimum Fan is present but rotating too slowly or stopped above minimum Fan is rotating too quickly unknown Unknown fan unit installed faulty Fan has exceeded hardware tolerance and has stopped In this case the last known fan ...

Page 201: ...he reboot takes effect immediately as the CP resets and executes normal power on booting sequence However POST is skipped reducing boot time significantly If POST has been disabled using the diagDisablePost command then fastBoot is the same as reboot Operands none Examples To perform a reboot without executing POST See also diagDisablePost diagEnablePost reboot fastBoot switch admin fastboot ...

Page 202: ...command has the following required operands Examples To add aliases for some disk arrays to Blue_fazone To add a Fabric Assist host member to Blue_fazone faZoneAdd fazoneName Specify the name of the Fabric Assist zone in quotation marks member Specify a list of Fabric Assist zone members The whole list must be enclosed in quotation marks and members separated by semicolons A member can be specifie...

Page 203: ...abric OS 5 x command reference guide 203 To add another target member to Blue_fazone See also faZoneCreate faZoneDelete faZoneRemove faZoneShow switch admin fazoneadd Blue_fazone 10 49 00 00 00 20 3f 2e ...

Page 204: ... Fabric Assist zone member is specified by node name then all ports on that device are in the Fabric Assist zone When a Fabric Assist zone member is specified by port name only that single device port is in the Fabric Assist zone Zone alias names have the same format as Fabric Assist zone names and are created with the aliCreate command The alias must resolve to a list of one or more physical fabr...

Page 205: ...to add to a Fabric Assist zone The list must be enclosed in quotation marks members separated by semicolons A member can be specified by one or more of the following methods Enter a fabric domain and area number pair for example 1 2 View the area numbers for ports using the switchShow command WWNs for example 10 49 00 00 00 20 3f 2e Fabric Assist zone alias names Exactly one Fabric Assist host mem...

Page 206: ... Fabric Assist zone configuration must be enabled using the cfgEnable command For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands The following operand is required Examples To delete a Fabric Assist zone See also faZoneAdd faZoneCreate faZon...

Page 207: ...abled using the cfgEnable command For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command NOTE When security is enabled this command can be issued only from the primary FCS switch Operands The following operands are required Examples To remove array2 from Blue_fazone faZoneRemove fazoneName Specify a name for the Fabric Assist zone in quotati...

Page 208: ...208 Fabric OS commands See also faZoneAdd faZoneCreate faZoneDelete faZoneShow ...

Page 209: ...security is enabled this command can be issued only from the primary FCS switch Operands This command has the following optional operands Examples To display all Fabric Assist zones beginning with the letters A through C See also faZoneAdd faZoneCreate faZoneDelete faZoneRemove faZoneShow pattern Specify a value to search for the name of a Fabric Assist zone This can be any POSIX style expression ...

Page 210: ...fied by l length to fill out the request frame The source identifier in the ELS ECHO request is the domain controller and the destination identifier is either source or destination The echo ELS might not be supported on all devices In such cases the response could be either an ELS reject or a request timeout By default fcPing sends five ELS ECHO requests to each port NOTE When a device does not re...

Page 211: ...e c4 21 00 00 20 37 25 ad 05 Source 10 00 00 00 c9 29 0e c4 Destination 21 00 00 20 37 25 ad 05 Zone Check Not Zoned Pinging 10 00 00 00 c9 29 0e c4 0x20800 with 12 bytes of data received reply from 10 00 00 00 c9 29 0e c4 12 bytes time 1162 usec received reply from 10 00 00 00 c9 29 0e c4 12 bytes time 1013 usec received reply from 10 00 00 00 c9 29 0e c4 12 bytes time 1442 usec received reply fr...

Page 212: ...ceived reply from 0x20800 12 bytes time 1006 usec received reply from 0x20800 12 bytes time 1008 usec received reply from 0x20800 12 bytes time 1038 usec received reply from 0x20800 12 bytes time 1010 usec 5 frames sent 5 frames received 0 frames rejected 0 frames timeout Round trip min avg max 1006 1044 1159 usec Pinging 22 00 00 04 cf 75 63 85 0x217d9 with 12 bytes of data Request timed out Requ...

Page 213: ...og debug command Synopsis fcpLogClear Availability admin Description Use this command to clear the debug information logged by FCPD Operands none Examples To clear the FCPD debug information log See also fcpLogDisable fcpLogEnable fcpLogShow fcpLogClear switch admin fcplogclear ...

Page 214: ...ommand Synopsis fcpLogDisable Availability admin Description Use this command to disable the debug information logged by FCPD Operands none Examples To disable the FCPD debug information log See also fcPing fcpLogEnable fcpLogShow fcpLogDisable switch admin fcpLogDisable ...

Page 215: ...is fcpLogEnable Availability admin Description Use this command to enable the debug information logged for FCPD Debug information logging is enabled by default Operands none Examples To enable the FCPD debug information log See also fcPing fcpLogDisable fcpLogShow fcpLogEnable switch admin fcpLogEnable ...

Page 216: ...Flsh 26 1 2755 1 0 0 0 0 22 34 14 234 SndPLOGI 26 1 1431 1002a690 11ace 1 0 20526 22 34 14 236 AsyResp 26 1 1540 1002a690 1002a768 80 1 10526 22 34 14 236 ElsRsp 26 1 1606 11ace 2000000 20 0 980000 22 34 14 238 SndPRLI 26 1 2026 1002a690 11ace 2 527 0 22 34 14 239 AsyResp 26 1 1540 1002a690 1002a8e8 80 2 10527 22 34 14 239 ElsRsp 26 1 1606 11ace 2100014 0 21 980000 22 34 14 240 SndINQ 26 1 2504 10...

Page 217: ...Fabric OS 5 x command reference guide 217 See also fcPing fcpLogDisable fcpLogEnable ...

Page 218: ...pProbeShow slotnumber For bladed systems only specify the slot number of the port to display followed by a slash portnumber Specify the port number to display relative to its slot for bladed systems Use switchShow to list valid ports This operand is required switch admin fcpprobeshow 4 4 port 52 is L Port and it is online nodes probed 2 successful PLOGIs 2 successful PRLIs 2 successful INQUIRies 2...

Page 219: ...Fabric OS 5 x command reference guide 219 See also portLoginShow portLogShow ...

Page 220: ...r and other failure events that have been detected on this port Operands This command has the following operands Examples To display the FCP RLS information See also portLoginShow portLogShow fcpRlsShow slotnumber For bladed systems only specify the slot number of the port to display followed by a slash portnumber Specify the port number to display relative to its slot for bladed systems Use switc...

Page 221: ... switch also displays followed by the world wide name of the switch For HBAs only the HBA identifiers and registered port lists are displayed No detailed HBA attributes are displayed For registered ports only port identifier and corresponding HBA are shown no detailed port attributes are displayed Operands none Examples To display the FDMI cache See also fdmiShow fdmiCacheShow switch admin fdmicac...

Page 222: ...on a local switch fdmiShow switch admin fdmishow Local HBA database contains 10 00 00 00 c9 25 9b 96 Ports 1 10 00 00 00 c9 25 9b 96 Port attributes FC4 Types 0x0001000001000000000000000000000000000000000000000000000000000000 Supported Speed 0x00000001 Port Speed 0x00000001 Frame Size 0x00000800 HBA attributes Node Name 20 00 00 00 c9 25 9b 96 Manufacturer Emulex Network Systems Serial Number 0000...

Page 223: ...Fabric OS 5 x command reference guide 223 See also fdmiCacheShow Local Port database contains 10 00 00 00 c9 25 9b 96 Remote HBA database contains no entry Remote Port database contains no entry ...

Page 224: ... RLIR database To clear RNID database See Also ficonHelp ficonShow ficonClear database Specifies the name of the FICON database The databases are RLIR Removes all entries from the link incidents database RNID Removes all the not current entries from the device node identification database There are four devices that are not removed from the RNID database switch user ficonclear RLIR successfully cl...

Page 225: ... for the switch To set ASM bit in the mode register for the switch See Also ficoncupshow ficoncupset fmsmode Enable or disable the FICON Management Server FMS mode for the switch When parameter is fmsmode argument is either enable or disable modereg Set a bit in the FICON CUP mode register When parameter is modereg one of the following bitname operands should be specified followed by 0 or 1 POSC P...

Page 226: ...CON CUP mode register When parameter is modereg one of the following arguments can be specified as bitname modereg POSC Programmed offline state control UAM User alert mode ASM Active saved mode DCAM Director clock alert mode ACP Alternate control prohibited HCP Host control prohibited If no argument is specified all the mode register bits are displayed If a mode register bit is specified then onl...

Page 227: ...Fabric OS 5 x command reference guide 227 To display ASM bit in the mode register for the switch See Also ficoncupset switch user ficoncupshow modereg ASM ASM 1 ...

Page 228: ... RNID fabric Displays all RNID entries within the fabric ficonshow LIRR Displays all LIRR Link Incident Record Registration entries for FICON hosts that registered with the local switch ficonshow LIRR fabric Displays all LIRR entries within the fabric ficonshow SwitchRNID Displays switch node identification data of the local switch ficonshow SwitchRNID fabric Displays switch node identification da...

Page 229: ...R Implicit Link Incident Record entries within the local switch ficonshow ILIR fabric Displays all ILIR entries within the fabric ficonclear RLIR Clears the RLIR entries from the local RLIR database ficonclear RNID Clears the not current entries from the local RNID database ...

Page 230: ...pending on which database you enter and which operands you use with the command ficonShow Domain Displays the domain ID Fabric WWN Displays the fabric WWN Flag Indicates if the node is valid not valid or not current Flag values are as follows 0x00 Indicates node ID of the storage port for RNID switch for SwitchRNID is valid 0x10 Indicates node ID of the channel port is valid 0x20 Indicates the nod...

Page 231: ...ation list have been chosen Unconditional This port is always chosen as a recipient of a link incident record Manufacturer Displays the manufacturer name or code Model Number Displays the model number Node Parameters Same as Parameters Parameters Displays the node type for the switch in three bytes 0xAABBCC Byte AA 0x20 FC SB 2 and updates Byte BB 0x0a Switch Byte CC 0x00 Port number It is dynamic...

Page 232: ...hassis part number PID Displays the 24 bit Fibre Channel port address in 0xDDAAPP format DD is Domain ID AA is Area ID PP is AL_PA ID Plant of Manufacture Displays the manufacturer plant name or code Port Physical port number Port Status Displays the status of the port Link degraded but operational Link not operational Port Type Displays the port type U is unknown N is N_Port NL is NL_Port Protoco...

Page 233: ...l and remote information if omitted only members of the named database that are local to the switch on which the command is issued displays switch admin ficonshow RNID Fmt Type PID Registered Port WWN Registered Node WWN flag Parm 0x18 N 502b00 50 05 07 64 01 00 15 8d 50 05 07 64 00 c1 69 ca 0x10 0x200110 Type number 002064 Model number 101 Manufacturer IBM Plant of Manufacture 02 Sequence Number ...

Page 234: ...60 69 80 1e 4e Conditional 0x18 N 511b00 50 05 07 64 01 00 0f ca 20 1b 00 60 69 80 1e 4f Conditional 0x18 N 511c00 50 05 07 64 01 40 0d d0 20 1c 00 60 69 80 1e 4f Conditional 0x18 N 531800 50 05 07 64 01 40 13 70 20 18 00 60 69 33 33 33 Conditional The LIRR database has 5 entries switch admin ficonshow SwitchRNID Switch WWN flag Parm 10 00 00 60 69 80 1e 4e 00 200a00 Type number 002109 Model numbe...

Page 235: ...synchronization Registered Port WWN Registered Node WWN Flag Node Parameters 50 05 07 64 01 40 0f ca 50 05 07 64 00 c1 69 ca 0x50 0x200105 Type Number 002064 Model Number 101 Manufacturer IBM Plant of Manufacture 02 Sequence Number 0000000169CA tag 2e00 Switch Port WWN Switch Node WWN Flag Node Parameters 20 2e 00 60 69 80 1e 4e 10 00 00 60 69 80 1e 4e 0x00 0x200a2e Switch Part Number 060 0001501 ...

Page 236: ... number 23000000602 FRU serial number FL2L0001071 Listener Port Type Listener PID Listener Port WWN N 0x502b00 50 05 07 64 01 00 15 8d FRU Failure 3 Power Supply 4 failure occurred on Mon Jan 13 12 11 38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10 00 00 60 69 33 33 33 10 00 00 60 69 80 1e 4e FRU part number 23000000602 FRU serial number FL2L0001060 Listener Port Type Listener P...

Page 237: ...ltering conditions shown in Table 11 filterTest FLTACT_LIST_A Action to handle the subgroup A based filtering FLTACT_LIST_B Action to handle the subgroup B based filtering FLTACT_FROZEN Action to handle the frame frozen process FLTACT_DISCARD Action to discard frame FLTACT_FORWARD Action to forward frame Table 11 List of filter test numbers definitions and action types Number Filter definition Act...

Page 238: ...perate on fixed port count products passcnt passcnt Specify the number of times to perform this test The default value is 1 txports itemlist Specify the user port numbers to perform this test All user ports are set by default scamoff offset Specify the program location to write SCAM test data in SCAM memory The default value is 0 The maximum offset number is set if the specified number is larger t...

Page 239: ...CP is rebooted the system switches the primary partition with the old firmware to the secondary and the secondary partition with the new firmware to the primary The default behavior of the firmwareDownload command is to automatically run the firmwareCommit command after the reboot If you decide to disable the autocommit option when running firmwareDownload after the CP is rebooted you must execute...

Page 240: ...240 Fabric OS commands See also firmwareDownload firmwareRestore ...

Page 241: ...e into the secondary partition and swaps the secondary partition to be the primary It then reboots the CP and activates the new image Finally it performs the firmwareCommit procedure automatically to copy the new image to the other partition unless n is used The command supports both noninteractive and interactive modes If it is invoked without any command line parameters or if there is any syntax...

Page 242: ...itions of a CP i Specify to activate incremental upgrade mode By default this command installs all the packages in the pfile When this mode is enabled the names of the packages in pfile are compared to those installed on the switch and only the packages whose names are different are installed host Specify a host server name or IP address for example citadel or 192 168 166 30 The pfile is downloade...

Page 243: ...nload 192 168 166 30 johndoe pub dist release plist 12345 This command will upgrade both CPs in the switch If you want to upgrade a single CP only please use s option You can run firmwareDownloadStatus to get the status of this command This command will cause the active CP to reset and will require that existing telnet secure telnet or SSH sessions be restarted Do you want to continue Y FirmwareDo...

Page 244: ...S commands See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also firmwareCommit firmwareDownloadStatus firmwareRestore firmwareShow reboot version ...

Page 245: ... is run the event logs whether the two CPs are synchronized The command can be run from either CP Operands none Examples To display the status of a firmware download firmwareDownloadStatus switch admin firmwaredownloadstatus 1 Tue Jan 18 13 21 25 2004 cp1 Firmwaredownload has started on Standby CP This step will take up to 30 minutes 1 Tue Jan 18 13 21 35 2004 cp1 Firmwaredownload has completed su...

Page 246: ...Firmwaredownload has completed successfully on Standby CP 8 Tue Jan 18 13 31 23 2004 cp0 Standby CP starts reboot 9 Tue Jan 18 13 33 54 2004 cp0 Standby CP booted up with new firmware 10 Tue Jan 18 13 33 56 2004 cp0 Firmwarecommit has started on both Active and Standby CPs 11 Tue Jan 18 13 38 29 2004 cp0 Firmwarecommit has completed successfully on Active CP 12 Tue Jan 18 13 38 30 2004 cp0 Firmwar...

Page 247: ...unning firmwareRestore you can run firmwareDownload again This command reboots the system and makes the former firmware active After reboot both primary and secondary partitions restore to the former firmware This command only takes action if the system is booted after a firmwareDownload otherwise it returns with an error code Operands none Examples To restore the former active firmware image See ...

Page 248: ...s Operands none Examples To display the firmware version of a single CP system To display the firmware version of a dual CP system See also firmwareDownload firmwareDownloadStatus firmwareShow switch admin firmwareshow Primary partition v5 0 1 Secondary Partition v5 0 1 switch admin firmwareshow Local CP Slot 5 CP 1 Active Primary partition v5 0 1 Secondary Partition v5 0 1 Remote CP Slot 6 CP 0 S...

Page 249: ...the test is running The test method is as follows 1 Determine which ports are F_Ports 2 Create an ELS_ECHO frame with payload size data pattern build in or payload size data pattern 3 Transmit frame F through the F_Port with D_ID to the N_Port device 4 Wait for the N_Port device to respond ECHO ACC 5 Compare ECHO data transmitted to ECHO data received 6 Repeat steps 3 through 5 for all ports prese...

Page 250: ...is test If count is omitted the default of 10 is used ports itemlist Specify the ports to test If itemlist is omitted the test is executed on all online F_Ports in the specified slot seed payload_pattern Specify the pattern of the test packets payload Valid values are 0 CSPAT default 1 BYTE_LFST 2 CHALF_SQ 3 QUAD_NOT 4 CQRT_SQ 5 CRPAT 6 RANDOM width pattern_width Specify the width of the pattern V...

Page 251: ...ERR LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERR NO_SEGMENT PORT_ABSENT PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also crossPortTest itemList loopPortTest portTest spinFab ...

Page 252: ...ce FRU Specify the type of hardware component being replaced WWN is the only supported value it specifies the replacement of the WWN card switch admin frureplace wwn This is the WWN card hot swap interface Continuing from this point will require the whole process to be completed If this process is not complete due to a power cycle or CP failover please follow the recovery procedure in Core Switch ...

Page 253: ...d follow the instructions to complete the operation Please enter the word continue after the new WWN card has been installed continue Restoring the information to the replacement FRU now please wait about 20 seconds to complete Verifying the replacement FRU now WWN card hot swap is now complete FRU replacement completed successfully ...

Page 254: ...itch is currently confirmed isl_ports Bit map of all the ISL ports Bit positions correspond to the default areas of the ports Bit 0 refers to default area of the switch bit 1 refers to default area 1 and so forth trunk_ports Bit map of all the trunk slave ports f_ports Bit map of all the Fx_Ports seg_ports Bit map of all the segmented ports active_ports Bit map of all the ONLINE ports minLSArrival...

Page 255: ... switch admin fspfshow version 2 domainID 131 switchOnline TRUE domainValid TRUE isl_ports 0 0x00000000 isl_ports 1 0x74000000 trunk_ports 0 0x00000000 trunk_ports 1 0x02000000 f_ports 0 0x00400000 f_ports 1 0x00000000 seg_ports 0 0x00000000 seg_ports 1 0x00000000 active_ports 0 0x00400000 active_ports 1 0x76000000 minLSArrival 3 minLSInterval 5 LSoriginCount 3 startTime 50222 fspfQ 0x1003e640 fab...

Page 256: ...256 Fabric OS commands See also bcastShow topologyShow uRouteShow ...

Page 257: ... suppressed By turning on the alarms all class alarms are generated Operands This command has the following operand Examples To enable alarms in Fabric Watch See also fwAlarmsFilterShow fwAlarmsFilterSet mode Specify 1 to enable the alarms 0 to disable the alarms If no operand is specified the default value is 0 alarms deactivated This operand is optional switch admin fwalarmsfilterset Committing ...

Page 258: ... a Fabric Watch license Description Use this command to display whether alarm filtering is enabled or disabled Operands none Examples To display the status of alarm filtering in Fabric Watch See also fwAlarmsFilterSet fwAlarmsFilterShow switch user fwalarmsfiltershow FW Alarms are enabled switch user fwalarmsfiltershow FW Alarms are disabled ...

Page 259: ...ialize all classes under Fabric Watch The command should be used only after installing a Fabric Watch license to start licensed Fabric Watch classes See fwConfigure for a list of classes Operands none Examples To initialize all classes under Fabric Watch See also fwConfigReload fwConfigure fwShow fwClassInit switch admin fwclassinit fwClassInit Fabric Watch is updating fwClassInit Fabric Watch has...

Page 260: ...mmand to reload the Fabric Watch configuration This command should be used only after downloading a new Fabric Watch configuration file from a host Operands none Examples To reload the saved Fabric Watch configuration See also configDownload configUpload fwClassInit fwConfigure fwShow fwConfigReload switch admin fwconfigreload fwConfigReload Fabric Watch configuration reloaded ...

Page 261: ...re divided into classes which are further divided into areas Each area can include multiple thresholds In addition the command can be used to disable or enable all thresholds associated with a given port The Fabric Watch classes and areas are provided in Table 13 NOTE Not all platforms support fans or power supplies If you attempt to configure values for these items an ERROR No threshold available...

Page 262: ... Changes Fabric E_Port downs Fabric reconfigure Domain ID changes Segmentation changes Zone changes Fabric QL Fabric logins SFP state changes E_Port Link loss Sync loss Signal loss Protocol error Invalid words Invalid CRCS RXPerformance TXPerformance State Changes Table 13 fwConfigure fabric watch classes and areas continued Class Area ...

Page 263: ...ocol error Invalid words Invalid CRCS RXPerformance TXPerformance State Changes AL_PA Performance Monitor Invalid CRCS EE Performance Monitor Invalid CRCS RXPerformance TXPerformance Filter Performance Monitor Customer Define Table 13 fwConfigure fabric watch classes and areas continued Class Area ...

Page 264: ... SCC Violations DCC Violations Login Violations Invalid Timestamps Invalid Signatures Invalid Certificates SLAP Failures SLAP Bad Packets TS Out of Sync No FCS Incompatible Security DB Illegal Command Resource Flash Table 13 fwConfigure fabric watch classes and areas continued Class Area enable port portNumber Enables all thresholds associated with a certain port disable port portNumber Disables a...

Page 265: ...e Select an area 1 4 4 1 Index ThresholdName Status CurVal LastEvent LastEventTime LastVal LastState 1 envTemp001 enabled 33 C started 10 28 59 on 02 01 2000 0 C Informative 2 envTemp002 enabled 34 C started 10 28 59 on 02 01 2000 0 C Informative 3 envTemp003 enabled 36 C started 10 28 59 on 02 01 2000 0 C Informative 4 envTemp004 enabled 35 C started 10 28 59 on 02 01 2000 0 C Informative 5 envTe...

Page 266: ...266 Fabric OS commands See also fwClassInit fwConfigReload fwShow ...

Page 267: ...ommand to configure FRU states and actions Based on these configuration settings Fabric Watch generates action when an FRU state changes To configure e mail alerts use fwMailCfg NOTE This command is not applicable to platforms without FRUs Operands This command has the following operand If no operand is specified the configuration prompt appears fwFruCfg show Displays the current FRU configuration...

Page 268: ...e value 0 for a parameter means that it is NOT used in the calculation Configurable Alarm States are Absent 1 Inserted 2 On 4 Off 8 Faulty 16 Configurable Alarm Actions are Errlog 1 E mail 16 Slot Alarm State 0 31 0 3 Slot Alarm Action 0 17 1 Power Supply Alarm State 0 31 0 Power Supply Alarm Action 0 17 0 Fan Alarm State 0 31 0 Fan Alarm Action 0 17 0 WWN Alarm State 0 31 0 WWN Alarm Action 0 17 ...

Page 269: ... all Fabric Watch classes fwConfigure Configure Fabric Watch fwConfigReload Reload Fabric Watch configuration fwFruCfg Configure FRU state and notification fwMailCfg Configure Fabric Watch Email Alert fwPortDetailShow Create a report with detailed port information fwSamShow Show availability monitor information fwSet Set port persistence time fwSetToCustom Set boundary alarm level to custom fwSetT...

Page 270: ...classes Each class can configure one e mail address as the alert message s receiver For an e mail alert to function correctly add the CP0 and CP1 IP addresses and hostname to DNS and also set the domain name and name server The ipAddrShow and dnsConfig commands can be used to set and check this information Operands none Examples To configure an e mail settings fwMailCfg switch admin fwmailcfg 1 Sh...

Page 271: ...erformance Monitor class 9 Filter Performance Monitor class 10 Security class 11 Resource class 12 FRU Class 13 Quit Select an item 0 13 11 1 mail configuration information Email Alert disable Mail Recipients NONE 1 Show Mail Configuration Information 2 Disable Email Alert 3 Enable Email Alert 4 Send Test Mail 5 Set Recipient Mail Address for Email Alert 6 Quit Select an item 1 6 6 5 continued on ...

Page 272: ...lass 3 Port class 4 Fabric class 5 E Port class 6 F FL Port Optical class 7 Alpa Performance Monitor class 8 End to End Performance Monitor class 9 Filter Performance Monitor class 10 Security class 12 FRU Class 13 Quit Select an item 0 13 11 1 Mail To NONE JoeDoe bogus com Email Alert configuration succeeded ...

Page 273: ...rrences exceeded limit for time period PER Number of protocol errors exceeded limit for time period INW Number of invalid words exceeded limit for time period CRC Number of invalid CRC errors exceeded limit for time period PSC Port hardware state changed too often BLP Buffer limit port SFP Errors STM SFP temperature is out of specification SRX SFP receive power is out of specification STX SFP tran...

Page 274: ...itch Name switch IP address 10 255 255 255 Port Exception report by Healthy Port Errors SFP Errors Port Type State Dur H M LFA LSY LSI PER INW CRC PSC BLP STM SRX STX SCU SV0 000 E HEALTHY 001 11 001 E HEALTHY 001 11 002 F HEALTHY 001 11 003 F HEALTHY 001 11 004 E HEALTHY 001 11 005 E HEALTHY 001 11 006 E HEALTHY 001 11 007 E HEALTHY 001 11 008 E HEALTHY 001 11 009 F HEALTHY 001 11 022 F HEALTHY 0...

Page 275: ...e State Dur H M LFA LSY LSI PER INW CRC PSC BLP STM SRX STX SCU SV0 000 E HEALTHY 001 11 001 E HEALTHY 001 11 002 F HEALTHY 001 11 003 F HEALTHY 001 11 004 E HEALTHY 001 11 005 E HEALTHY 001 11 006 E HEALTHY 001 11 007 E HEALTHY 001 11 008 E HEALTHY 001 11 009 F HEALTHY 001 11 022 F HEALTHY 001 11 023 F HEALTHY 001 11 024 E HEALTHY 001 11 025 E HEALTHY 001 11 026 F HEALTHY 001 11 027 F HEALTHY 001...

Page 276: ... total downtime number of faulty occurrences and total percent of downtime for each port Operands none Examples To display port summary information on an eight port switch See also portShow switchShow fwSamShow switch user fwsamshow Total Total Down Total Port Type Up Time Down Time Occurrence Offline Time Percent Percent Times Percent 0 U_PORT 0 0 0 100 1 U_PORT 0 0 0 100 2 U_PORT 0 0 0 100 3 E_P...

Page 277: ...ort persistence time time in which a port must persistently be in a marginal state before being labeled as such Operands The operand is as follows Examples To set message levels and port persistence time See also fwShow fwSet port persistence seconds Set port parameters Currently only port persistence time can be set with this option Port persistence time is the time period in which a port must be...

Page 278: ...This command requires a Fabric Watch license Description Use this command to set boundary and alarm levels to custom values for all classes and areas in Fabric Watch Operands none Examples To set alarm levels to custom values See also fwSetToDefault fwSetToCustom switch admin fwsettocustom Committing configuration done ...

Page 279: ... admin NOTE This command requires a Fabric Watch license Description Use this command to return boundary and alarm levels to defaults for all classes and areas in Fabric Watch Operands none Examples To return alarm levels to default values See also fwSetToCustom fwSetToDefault switch admin fwsettodefault Committing configuration done ...

Page 280: ...y thresholds and port persistence time fwShow port persistence Displays the time that a port must be persistently in a state before being marked as such disable port Displays the ports that have all associated thresholds disabled switch user fwshow 1 Show class thresholds 2 Detail threshold information 3 Show console message level 4 Show port persistence time 5 Quit Select an item 1 3 3 1 1 Enviro...

Page 281: ...M envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch user fwshow 1 Show class thresholds 2 Detail threshold information 3 Show console message level 4 Show port persistence time 5 Quit Select an item 1 3 3 2 Enter Threshold Name envFan001 Env Temperature 1 Monitored for 1283 21 mins Last checked 10 50 21 on 02 01 2000 Lower bound 0 C Upper bound 75 C Buffer Size 10 Value history 33 C...

Page 282: ...38 Events Style Triggered Event 0 occurred 1 time last at 16 30 17 on 12 09 2011 Event 1 occurred 10 times last at 16 49 02 on 12 09 2011 Event 5 occurred 1 time last at 16 30 23 on 12 09 2011 Callbacks No callbacks are registered switch user fwshow port persistence FW current port persistence time 18s switch user fwshow port persistence FW current port persistence time 18s switch user fwShow disa...

Page 283: ... typed into the shell the oldest commands are replaced as new ones are entered To edit a command press ESC to access edit mode and then use vi commands The ESC key switches the shell to edit mode The ENTER key gives the line to the shell from either editing or input mode Basic vi commands are as follows k Move the cursor up j Move the cursor down h Move the cursor left l Move the cursor right a Ap...

Page 284: ...Availability admin Description Use this command to disable the High Availability feature in the switch If the HA feature is already disabled this command does nothing Operands none Examples To disable the High Availability feature See also haEnable haDisable switch admin hadisable HA is disabled ...

Page 285: ...ge Operands none haDump Healthy The standby CP is running and the background health diagnostic has not detected any errors Failed The standby CP is running but the background health diagnostic has discovered a problem Failover is disabled until the standby CP is repaired The information of the failing device in the standby CP is displayed Unknown The standby CP healthy state is unknown due to not ...

Page 286: ...ot 5 CP0 Standby Healthy HA enabled Heartbeat Up HA State synchronized ipaddrshow SWITCH0 Ethernet IP Address 10 64 118 104 Ethernet Subnetmask 255 255 240 0 Fibre Channel IP Address 0 0 0 0 Fibre Channel Subnetmask 0 0 0 0 SWITCH1 Ethernet IP Address 10 64 118 105 Ethernet Subnetmask 255 255 240 0 Fibre Channel IP Address 0 0 0 0 Fibre Channel Subnetmask 0 0 0 0 output truncated ...

Page 287: ...ble Availability admin Description Use this command to enable the High Availability feature in the switch If the HA feature is already enabled this command does nothing Operands none Examples To enable the High Availability feature in the switch See also haDisable haEnable switch admin haenable HA is enabled ...

Page 288: ... dual CP cards Operands none Examples To force the failover of the active CP to the standby CP in the switch See also haDisable haEnable haShow haFailover switch admin hafailover Local CP Slot 6 CP1 Active Remote CP Slot 5 CP0 Standby Healthy HA enabled Heartbeat Up HA State synchronized Warning This command is being run on a redundant control processor CP system If the above status does not indic...

Page 289: ...tected any errors Failed The standby CP is running but the background health diagnostic has discovered a problem with the blade The logs should be checked to determine the appropriate repair action Failover is disabled until the standby CP is repaired Unknown The standby CP healthy state is unknown due to not existing heartbeat is down or healthy monitor detects a configuration file error HA State...

Page 290: ...switch admin hashow Local CP Slot 6 CP1 Active Remote CP Slot 5 CP0 Standby Healthy HA Enabled Heartbeat Up HA State Synchronized switch admin hashow Local CP Slot 6 CP1 Active Remote CP Slot 5 CP0 Standby Failed Backplane PCI fail severity CRITICAL HA enabled Heartbeat Up HA State not in sync ...

Page 291: ...nopsis hasyncstart Availability admin Description Use this command to enable the HA state synchronization Operands none Examples To enable the HA state synchronization See also haFailover haShow haSyncStop haSyncStart switch admin hasyncstart HA State synchronization has started ...

Page 292: ...ility admin Description Use this command to temporarily disable the HA synchronization The next failover that takes place after might be disruptive Operands none Examples To disable the HA state synchronizing process See also haFailover haShow haSyncStart haSyncStop switch admin hasyncstop ...

Page 293: ...ist of diagnostic commands The list displays only commands that are available to the current user this can vary according to Login user level License key Switch model To access help information for a specific command enter the command name as an operand Operands This command has the following optional operand Examples To display help information for the passwd command See also diagHelp fwHelp lice...

Page 294: ...yShow historyLastShow Object type CHASSIS FAN POWER SUPPLY SW BLADE port blade CP BLADE control processor WWN world wide name card or UNKNOWN Object number Slot number for blades and unit number for everything else Event Inserted Removed or Invalid Time of the event at Day Mon dd hh mm ss yyyy The second and third lines of a record each contain one data set preceded by its name Factory Part Number...

Page 295: ...ory buffer Operands none Examples To change the history mode to first in from rotating See also historyLastShow historyShow historyMode Rotating mode New messages overwrite the oldest messages in the log First in mode Once the log is full all additional logs are discarded so that the first set of logs to fill the buffer are preserved switch admin historymode History Mode is Rotating ...

Page 296: ...rst line of each record contains the following The second and third lines of a record respectively contain the factory part number and factory serial number if applicable Operands none historyShow Object type CHASSIS FAN POWER SUPPLY SW BLADE port blade CP BLADE control processor WWN WWN card or UNKNOWN Object number Slot number for blades and unit number for everything else Event type Inserted Re...

Page 297: ...4 11 03 45 2001 Factory Part Number 40 0000031 03 Factory Serial Number 1013456800 output truncated SW BLADE Slot 3 Removed at Tue Aug 14 12 10 09 2001 Factory Part Number 60 0001532 03 Factory Serial Number 1013456800 CP BLADE Slot 6 Removed at Tue Aug 14 13 45 07 2001 Factory Part Number 60 0001604 02 Factory Serial Number FP00X600128 SW BLADE Slot 3 Inserted at Tue Aug 14 13 53 40 2001 Factory ...

Page 298: ...298 Fabric OS commands See also historyLastShow ...

Page 299: ...display the version of the Java plug in supported by Web Tools This command also displays the URL from which the plug in can be downloaded Operands none Examples To display the Java plug in version See also none httpCfgShow switch admin httpcfgshow Current HTTP configuration javaplugin version 1 3 1 javaplugin homeURL http java sun com products plugin ...

Page 300: ... created EXITING 004 getting shut down PTRACED 010 set if ptrace 0 has been called TRACESYS 020 tracing system calls FORKNOEXEC 040 forked but did not exec SUPERPRIV 100 used super user privileges DUMPCORE 200 dumped core SIGNALED 400 killed by a signal S Process state codes D uninterruptible sleep usually IO R runnable on run queue S sleeping T traced or stopped Z a defunct zombie process UID The...

Page 301: ...event for which process is sleeping if blank process is running TTY The controlling terminal of the process printed for no controlling terminal TIME The cumulative execution time for the process CMD The command name of the process Table 14 i command field descriptions continued Field Description processID Specify the process name or process ID for the process to display switch admin i 433 F S UID ...

Page 302: ...lity to communicate with the system through its Ethernet interface It is recommended that this command only is used from the serial console port When used through an interface other than the serial console port the command displays a warning message and prompts the user to for verification before continuing this warning is not displayed and the user is not prompted when the command is used through...

Page 303: ...esult in an inability to communicate with the system through its ethernet interface It is recommended that you only use this command from the serial console port Are you sure you really want to do this yes y no n no y Proceed with caution Auto negotiate yes y no n no y Advertise 100 Mbps Full Duplex yes y no n yes y Advertise 100 Mbps Half Duplex yes y no n yes y Advertise 10 Mbps Full Duplex yes ...

Page 304: ...ommand has the following operand Examples To display the link operating mode for the eth0 Ethernet interface See also ifModeSet ifModeShow interface Specify the name of the interface You might specify the name with quotation marks but using them is not required For example you can use either eth0 or eth0 where eth is the network interface and 0 is the physical unit switch admin ifmodeshow eth0 Lin...

Page 305: ... a frame over the ISL connection to this interface cost Cost of sending a frame over the ISL connected to this interface A value of 1000 indicates a 1 Gb sec link A value of 500 indicates a 2 Gb sec link delay Conventional delay incurred by a frame transmitted on this ISL A fixed value required by the FSPF protocol lastScn Type of the last State Change Notification received on this interface lastS...

Page 306: ...out value in milliseconds When this timeout expires a Hello frame is sent to the neighbor switch through this port rXmitTo Retransmission timeout value in milliseconds It is used to transmit topology information to the neighbor switch If no acknowledgement is received within this value the frame is retransmitted nCmdAcc Total number of commands accepted from the neighbor switch Number includes Hel...

Page 307: ...owed by a slash portnumber Specify the port number to display relative to its slot for bladed systems Use switchShow to list valid ports This operand is optional if omitted the interface information for all ports is displayed switch user interfaceshow 1 4 idbP 0x1008b3d0 Interface 4 data structure nghbP 0x1008c668 ifNo 4 masterPort 4 self defaultCost 500 cost 500 delay 1 lastScn 16 lastScnTime Apr...

Page 308: ...1 44 460 firstHlo Apr 02 20 01 44 473 nbstFull Apr 02 20 01 44 512 delay 1 lastScn 16 dbRetransList 0x1008c6a0 lsrRetransList 0x1008c6c4 lsrAckList 0x1008c6e8 inactTID 0x1008c768 helloTID 0x1008c7a0 dbRtxTID 0x1008c7d8 lsrRtxTID 0x1008c848 inactTo 80000 helloTo 20000 rXmitTo 5000 nCmdAcc 7 nInvCmd 0 nHloIn 2 nInvHlo 0 nLsuIn 2 nLsaIn 3 attHloOut 2 nHloOut 2 attLsuOut 3 nLsuOut 3 attLsaOut 2 nLsaOu...

Page 309: ... enabling interoperability mode inspect the individual switches and the zoning database for compatibility disable any features not supported in interoperability mode and disable the Platform Management functions using the msPlMgmtDeactivate command When the switch is running in interoperability mode the following parameters cannot be changed using the configure command Port number zoning Node WWN ...

Page 310: ...o view and then enable interoperability mode See also configure switch admin interopmode InteropMode Off Usage InteropMode 0 1 0 to turn it off 1 to turn it on switch admin interopmode 1 done Interopmode is enabled switch admin reboot ...

Page 311: ... by default however if the IOD option was turned on using iodSet this command can be used to turn it off again Disabling IOD allows fast re routing after a fabric topology change This command might cause out of order delivery of frames during fabric topology changes Operands none Examples To turn off the IOD option See also iodSet iodShow iodReset switch admin iodreset switch admin iodshow IOD is ...

Page 312: ...around the failure and some frames might be delivered out of order This command ensures that frames are not delivered out of order even during fabric topology changes The default behavior is for the IOD option to be off This command should be used with care because it can cause a delay in the establishment of a new path when a topology change occurs Only if there are devices connected to the fabri...

Page 313: ...ption setting Synopsis iodshow Availability all users Description Use this command to display whether the IOD option is enabled or disabled Operands none Examples To display the current setting of the IOD option See also iodReset iodSet iodShow switch admin iodshow IOD is not set ...

Page 314: ...et IP address Ethernet subnetmask Fibre Channel IP address Fibre Channel subnetmask and gateway IP address Operands This command has the following operands on a chassis based system If no option is specified the command displays the usage Examples To set the IP address details for logical switch 1 on a chassis based system ipAddrSet cp number Valid options include 0 sets the Ethernet IP address Et...

Page 315: ...Fabric OS 5 x command reference guide 315 See also ipAddrShow ...

Page 316: ...lays the Ethernet IP address Ethernet subnetmask host name and gateway IP address Operands This command has the following operands If no operands are specified the command displays all the IP addresses configured in the system For nonchassis based switches this command ignores all operands Examples To display the IP address for logical switch 0 See also ipAddrSet ipAddrShow cp cp_number For dual C...

Page 317: ...ted the speed of the connection and whether this ISL is trunked are displayed Operands none Examples To display the ISL connections for the switch See also switchShow islShow switch admin islshow 1 33 29 10 00 00 60 69 80 4f 84 switch sp 2G bw 4G TRUNK 2 39 7 10 00 00 60 69 80 4f 84 switch sp 2G bw 8G TRUNK 3 41 incompatible 4 47 incompatible 5 57 25 10 00 00 60 69 80 4f 84 switch sp 2G bw 4G TRUN...

Page 318: ...with individual values Spaces and tab stops are skipped Each item might be preceded by an optional slot number and foward slash For example 0 3 4 6 1 0 1 3 4 5 6 and 0 3 4 6 1 each select items 0 1 3 4 5 6 Besides the syntax rules there are also some grammatical restrictions on the slot numbers Once specified a slot selection applies to all items to the right of the slot selections until the next ...

Page 319: ... tested When specified in an item list user ports might be specified by either the area portion of the ports Fibre Channel address or with slot port notation For nonblade systems the port number on the silkscreen is the area number so the two notations are identical The exact type of list required for any input parameter might be determined with the diagCommandShow command For item list parameters...

Page 320: ...n sessions It lists information such as the session number login name idle time IP address of the connection and timestamp of when the login session was opened A prompt is then displayed at which point you can specify the session number of the connection you want to terminate NOTE The list of open sessions displayed with killTelnet includes the user s current session Make sure you do not kill your...

Page 321: ...inate the telnet session logged in as admin0 from 192 168 130 29 since 6 29pm and has been inactive for 16 00s the current command executed being rbash The device entry is pts 0 This action will effectively kill these process es USER PID ACCESS COMMAND dev pts 0 root 12868 f login root 12869 f login root 12877 f rbash continued on next page Please Ensure Y N y killing session Done Collecting login...

Page 322: ...e is added to a switch that lacks a fabric license In this case the switch must be rebooted to allow the software to recognize the license and initialize itself correctly Also there is special handling required when a trunking license is added to the switch For a trunking license to become effective the trunk ports need to be refreshed using the commands portDisable and portEnable or the switch mu...

Page 323: ...display a list of the commands used to administer license keys Operands none Examples To display license commands See also licenseAdd licenseIdShow licenseRemove licenseShow licenseHelp switch admin licensehelp licenseAdd Add a license to this switch licenseIdShow Show system license ID licenseRemove Remove a license from this switch licenseShow Show current licenses ...

Page 324: ...nd are only functional on the specific system for which they were issued This command displays to standard output the system license ID used for both generating and validating licenses on the system The license ID format is eight pairs of hexadecimal values separated by colons Each hexadecimal value is between 00 0 and FF 255 NOTE While the format of this identifier might be similar or even identi...

Page 325: ...the licenseShow command to verify that the key has been removed and the licensed product uninstalled After removing a license key the switch must be rebooted With no license key licenseShow displays No licenses Operands The following operand is required Examples To remove a license key from the switch See also licenseAdd licenseHelp licenseIdShow licenseShow licenseRemove license Specify the licen...

Page 326: ...f licensed products enabled by these keys The message No license installed on this switch is displayed when no licenses are installed Operands none Examples To display the installed license keys on a switch See also licenseAdd licenseHelp licenseIdShow licenseRemove licenseShow switch admin licenseshow bQebzbRdScRfc0iK Web license Zoning license SybbzQQ9edTzcc0X Fabric license ...

Page 327: ...en those are not ISL s Active ISLs have an additional suffix of E_PORT attached to their interface number If the port has a static cost assigned to it then the suffix of STATIC is appended to the link cost In this case only the current link cost is displayed Use interfaceShow to display both the default and current link costs To remove a static cost from the database execute this command with a co...

Page 328: ...cost Slot Interface Cost 2 0 500 STATIC 2 1 1000 2 2 500 STATIC 2 3 200 STATIC 2 4 1000 2 5 1000 2 6 1000 2 7 1000 2 8 1000 2 9 1000 2 10 1000 2 11 E_PORT 2000 STATIC 2 12 1000 2 13 1000 2 14 1000 2 15 1000 switch admin linkcost 2 4 500 switch admin linkcost 2 4 Slot 2 Interface 4 Cost 500 STATIC switch admin linkcost 2 4 0 Slot 2 Interface 4 Cost 1000 ...

Page 329: ...d password without first logging out from the original session If the user was originally connected using a telnet or rlogin session that session is left open This command allows you to access commands that you cannot access at your current user level Operands none Examples To log in as admin from the login user See also logout login switch user login login admin Password xxxxxx ...

Page 330: ...in prompt The exit command is accepted as a synonym for logout as is Ctrl D at the beginning of a line NOTE If you close a telnet or sectelnet session by clicking the X in the upper right corner the window closes but the session stays open until it times out Trying to open another session before the timeout has completed causes an error message to display Operands none Examples To log out from an ...

Page 331: ...ed loopback mode 3 Create a frame F of data size 1024 bytes 4 Transmit frame F through port M with D_ID to the FL_Port AL_PA 0 5 Pick up the frame from port M the FL_Port 6 Check if any of the eight statistic error counters are nonzero ENC_in CRC_err TruncFrm FrmTooLong BadEOF Enc_out BadOrdSet DiscC3 7 Check if the transmit receive or class 3 receiver counters are stuck at some value 8 Check if t...

Page 332: ...AT 0x7e 0x7e 0x7e 0x7e 2 BYTE_LFSR 0x69 0x01 0x02 0x05 3 CHALF_SQ 0x4a 0x4a 0x4a 0x4a 4 QUAD_NOT 0x00 0xff 0x00 0xff 5 CQTR_SQ 0x78 0x78 0x78 0x78 6 CRPAT 0xbc 0xbc 0x23 0x47 7 RANDOM 0x25 0x7f 0x6e 0x9a width pattern_width Specify the width of the test pattern Valid values include 1 for byte default 2 for word 3 for quad This operand is optional switch admin loopporttest ports 1 0 1 15 Running Lo...

Page 333: ...T_FULL state This command displays the content of both types of database entries if both are present The fields described in Table 16 appear lSDbShow Table 16 lsdbShow display fields Field Description Domain Domain number described by this LSR A self keyword after the domain number indicates that LSR describes the local switch lsrP Pointer to LSR earlyAccLSRs Number of LSRs accepted even though th...

Page 334: ...tes of this LSR Includes header and link state information for all links chksum Checksum of total LSR with exception of lsAge field linkCnt Number of links in this LSR Each link represents a neighbor in NB_ST_FULL state flags Always 0 LinkId ID of this link It is the domain number of the switch on the other side of the link out port Port number on the local switch rem port Port number of the port ...

Page 335: ...reserved 0 type 1 options 0x0 lsId 1 advertiser 1 incarn 0x80000014 length 284 chksum 0x8453 linkCnt 16 flags 0x0 LinkId 2 out port 16 rem port 48 cost 500 costCnt 0 type 1 LinkId 2 out port 17 rem port 49 cost 500 costCnt 0 type 1 LinkId 2 out port 18 rem port 50 cost 500 costCnt 0 type 1 LinkId 2 out port 19 rem port 51 cost 500 costCnt 0 type 1 LinkId 2 out port 24 rem port 56 cost 500 costCnt ...

Page 336: ...st 500 costCnt 0 type 1 LinkId 2 out port 44 rem port 12 cost 500 costCnt 0 type 1 LinkId 2 out port 45 rem port 13 cost 500 costCnt 0 type 1 LinkId 2 out port 46 rem port 14 cost 500 costCnt 0 type 1 LinkId 2 out port 47 rem port 15 cost 500 costCnt 0 type 1 The local switch has sixteen links in NB_ST_FULL state all of them are connected to switch 2 ...

Page 337: ...s command has the following operands By default memory usage is displayed in bytes Examples To view the memory usage See also saveCore memShow b Specify to display memory usage in bytes k Specify to display memory usage in kilobytes m Specify to display memory usage in megabytes switch admin memshow total used free shared buffers cached Mem 129740800 112562176 17178624 0 139264 30396416 Swap 0 0 0...

Page 338: ...cle command Just like with spinSilk all ports are active and exchanging frames simultaneously with miniCycle The path number being tested determines the partner port N for each port M bold and italicized in the following example path 0 0 8 1 9 2 10 3 11 4 12 5 13 6 14 7 15 path 1 7 8 0 9 1 10 2 11 3 12 4 13 5 14 6 15 path 2 6 8 7 9 0 10 1 11 2 12 3 13 4 14 5 15 path 3 5 8 6 9 7 10 0 11 1 12 2 13 3...

Page 339: ...st besides the periodic checks of the hardware counters At the end of a path test all statistics and routes are reset for the next path test An example of the data used is as follows CSPAT 0x7e 0x7e 0x7e 0x7e RDRAM_PAT 0xff 0x00 0xff 0x00 BYTE_LFSR 0x69 0x01 0x02 0x05 RANDOM 0x25 0x7f 0x6e 0x9a Because this test includes the media and the fiber cable loopback plug in its test path its results comb...

Page 340: ...r 1 the following speed modes are available to test the speed negotiation 3 Set all even ports speed for auto negotiate Set all odd ports speed for 1 Gb s 4 Set all even ports speed for auto negotiate Set all odd ports speed for 2 Gb s 5 Set all odd ports speed for auto negotiate Set all even ports speed for 1 Gb s 6 Set all odd ports speed for auto negotiate Set all even ports speed for 2 Gb s Fo...

Page 341: ...ath 2 Spinning Path 3 Spinning Path 4 Spinning Path 5 Spinning Path 6 Spinning Path 7 Spinning Test Complete minicycle Pass 1 of 1 Duration 0 hr 1 min 4 sec 0 1 4 409 passed switch admin minicycle ports 0 1 2 8 lb_mode 1 Back Plane Loop Back mode is ON Running mini Cycle One moment please Path 0 Spinning Path 1 skipped Path 2 skipped Path 3 skipped Path 4 skipped Path 5 skipped Path 6 Spinning Pat...

Page 342: ...AT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT ERR_STAT_TRUNC FDET_PERR FINISH_MSG_ERR FTPRT_STATUS_ERR INIT LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS ...

Page 343: ...Fabric OS 5 x command reference guide 343 See also backport camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest ...

Page 344: ...ties minisPropShow slotnumber asicpair Specifies the index of the ASIC pair within the specified blade to be displayed If slotnumber is not provided the current slot is assumed slot slotnumber all Specifies the slot on which to operate The default is 0 and and designed to operate on fixed port count products switch user minispropshow 1 all slot 1 miniS 0 2 16 0 1657 0001 1 1657 0001 be 5 be 4 be 3...

Page 345: ...niS 2 2 16 4 1657 0001 5 1657 0001 be 17 be 16 be 15 be 14 be 13 be 12 bi 23 bi 22 bi 11 bi 10 bi 59 bi 58 fe 11 fe 10 fe 9 fe 8 slot 1 miniS 3 2 16 6 1657 0001 7 1657 0001 be 23 be 22 be 21 be 20 be 19 be 18 bi 7 bi 6 bi 27 bi 26 bi 43 bi 42 fe 15 fe 14 fe 13 fe 12 ...

Page 346: ...CS Operands none Examples To display Management Server capability on a fabric msCapabilityShow switch1 user mscapabilityshow Switch WWN Capability Name 10 00 00 60 69 20 15 71 0x0000008f switch1 10 00 00 60 69 00 30 05 0x0000008f switch2 Capability Bit Definitions Bit 0 Basic Config Service Supported Bit 1 Platform Management Service Supported Bit 2 Topology Discovery Service Supported Bit 3 Unzon...

Page 347: ...Fabric OS 5 x command reference guide 347 See also msConfigure msPlMgmtActivate msPlMgmtDeactivate msTdDisable msTdEnable msTdReadConfig ...

Page 348: ...ices 1 Done with the administration 2 Display the ACL 3 Add member based on its port node WWN 4 Delete member based on its port node WWN If the MS ACL is changed by adding or deleting WWNs an additional prompt is given asking if the MS ACL should be saved to nonvolatile storage The saved MS ACL becomes effective upon reboot The MS ACL is implemented on a per switch basis and should be configured o...

Page 349: ...Disable msTdEnable msTdReadConfig secPolicyShow MS Access List consists of 5 20 01 00 60 69 00 60 10 20 02 00 60 69 00 60 10 20 03 00 60 69 00 60 10 20 02 00 60 69 00 60 03 20 02 00 60 69 00 60 15 0 Done 1 Display the access list 2 Add member based on its Port Node WWN 3 Delete member based on its Port Node WWN select 0 3 1 0 done ...

Page 350: ...ds none Examples To display the MS platform database for a fabric msPlatShow switch admin msplatshow Platform Name 9 first obj Platform Type 5 GATEWAY Number of Associated M A 1 Associated Management Addresses 35 http java sun com products plugin Number of Associated Node Names 1 Associated Node Names 10 00 00 60 69 20 15 71 Platform Name 10 second obj Platform Type 7 HOST_BUS_ADAPTER Number of As...

Page 351: ...Fabric OS 5 x command reference guide 351 See also msCapabilityShow msConfigure msPlatShowDBCB msPlClearDB msPlMgmtActivate msPlMgmtDeactivate ...

Page 352: ...Operands none Examples To display the MS platform service database control block See also msCapabilityShow msConfigure msPlatShow msPlClearDB msPlMgmtActivate msPlMgmtDeactivate msPlatShowDBCB switch admin msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status 3 10 00 00 60 69 51 10 e6 0 0x2 msPlDBCB peerWwn 00 00 00 00 00 00 00 00 msPlDBCB psPeerWwn 00 00 00 00 00 00 00 00 msPlDBCB repl...

Page 353: ...establish an entirely new fabric with an empty database NOTE When security is enabled this command can be issued only from the primary FCS switch Operands none Examples To clear the MS platform database See also msCapabilityShow msConfigure msPlatShow msPlatShowDBCB msPlMgmtActivate msPlMgmtDeactivate msPlClearDB switch admin msplcleardb MS Platform Service is currently enabled This will erase MS ...

Page 354: ...tion all switches in the fabric boot with the MS platform service enabled By default the MS platform service is disabled Before issuing run the msCapabilityShow command to verify all switches in the fabric support MS platform service otherwise the command fails NOTE When security is enabled this command can be issued only from the primary FCS switch Operands none Examples To activate the MS platfo...

Page 355: ...e disabled NOTE When security is enabled this command can be issued only from the primary FCS switch Operands none Examples To deactivate the MS platform service on all switches in the fabric See also msCapabilityShow msConfigure msPlatShow msPlatShowDBCB msPlClearDB msPlMgmtActivate msPlMgmtDeactivate switch admin msplmgmtdeactivate MS Platform Service is currently enabled This will erase MS Plat...

Page 356: ...mand can be issued only from the primary FCS switch Operands This command has the following operand Examples To disable the MS topology discovery service on the local switch only To disable MS topology discovery on all the switches in the fabric msTdDisable ALL Disables the MS topology discovery service throughout the entire fabric This operand is optional switch admin mstddisable This may erase a...

Page 357: ...Fabric OS 5 x command reference guide 357 See also msTdEnable msTdReadConfig ...

Page 358: ...LL operand this command can be issued only from the primary FCS switch Operands This command has the following operand Examples To enable the MS topology discovery service on the local switch only To enable MS topology discovery on all the switches in the fabric See also msTdDisable msTdReadConfig msTdEnable ALL Enables the MS topology discovery service throughout the entire fabric This operand is...

Page 359: ...escription Use this command to check whether or not the management server topology discovery service is enabled Operands none Examples To display the status of the topology discovery service See also msCapabilityShow msConfigure msPlMgmtActivate msPlMgmtDeactivate msTdDisable msTdEnable msTdReadConfig switch admin mstdreadconfig MS Topology Discovery is enabled ...

Page 360: ...r console serial port used to log in The IP address of the current login session for telnet or the name of the current console port or the serial port if modem login used The current CP s mode Active Standby or Unknown The current system status Redundant Non Redundant or Unknown Operands none Examples To display current login information See also version myId switch admin myid Current Switch switc...

Page 361: ...ctly connected to the local switch See also interfaceShow nbrStateShow Local Domain ID Domain number of local switch Local Port E_Port interface on local switch Domain Domain number of remote switch Remote Port E_Port interface on remote switch State State of the neighbor The E_Port is used to route frames only if the neighbor is in NB_ST_FULL state slotnumber For bladed systems only specify the s...

Page 362: ...following operands When this command is specified with no operand the statistics are cleared for all interfaces Examples To reset the counters on a port nbrStatsClear slotnumber For bladed systems only specify the slot number of the port to display followed by a slash portnumber Specify the port number to display relative to its slot for bladed systems Use switchShow to list valid ports This opera...

Page 363: ...ut 12 nLsuOut 12 attLsaOut 17 nLsaOut 17 switch admin nbrstatsclear 1 0 switch admin interfaceshow 1 0 idbP 0x10050a38 Interface 0 data structure nghbP 0x1004ce68 ifNo 0 masterPort 0 self defaultCost 500 cost 500 output truncated nCmdAcc 0 nInvCmd 0 nHloIn 0 nInvHlo 0 nLsuIn 0 nLsaIn 0 attHloOut 0 nHloOut 0 attLsuOut 0 nLsuOut 0 attLsaOut 0 nLsaOut 0 ...

Page 364: ...364 Fabric OS commands See also interfaceShow portShow switchShow ...

Page 365: ...evice PID matching with the given PID or have a defined configuration alias to which the device belongs matching with the given alias The message No device is found displays if there is no device matching the given WWN PID or alias Operands This command has the following operand nodeFind WWN PID ALIAS Specify the WWN device PID or alias that can be used to match the real device s data WWN must hav...

Page 366: ...nent Port Name 22 00 00 04 cf 9f 78 7b Device type Physical Target Aliases a320 NL 0314d5 3 22 00 00 04 cf 9f 7d e0 20 00 00 04 cf 9f 7d e0 0 FC4s FCP SEAGATE ST336605FC 0003 Fabric Port Name 20 14 00 60 69 80 04 79 Permanent Port Name 22 00 00 04 cf 9f 7d e0 Device type Physical Target Aliases a320 NL 0314d4 3 22 00 00 04 cf 9f 26 7e 20 00 00 04 cf 9f 26 7e 0 FC4s FCP SEAGATE ST336605FC 0003 Fabr...

Page 367: ...e given no match See also aliShow nsAllShow nscamShow nsShow switch admin nodefind 0x020eef Remote Type Pid COS PortName NodeName NL 020eef 3 20 00 00 e0 8b 01 ce d3 20 00 00 e0 8b 01 ce d3 Fabric Port Name 20 0e 00 60 69 51 0b ba Permanent Port Name 20 00 00 e0 8b 01 ce d3 Device type Physical Target Aliases switch admin nodefind abcd No device found ...

Page 368: ...gistration SCR information in the display This value indicates what type of registered state change notification RSCN a device registers to receive Values include SCR 0 Reserved SCR 1 Fabric detected registration Register to receive all RSCN requests issued by the fabric controller for events detected by the fabric SCR 2 Nx_Port detected registration Register to receive all RSCN requests issued fo...

Page 369: ...214e2 3 21 00 00 fa ce 00 21 1e 20 00 00 fa ce 00 21 1e na FC4s FCP STOREX RS2999FCPH3 MT09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 1e Aliases NL 0214e4 3 21 00 00 fa ce 00 21 e1 20 00 00 fa ce 00 21 e1 na FC4s FCP STOREX RS2999FCPH3 CD09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 e1 Aliases MyAlias1 MyAlias2 NL 0214e...

Page 370: ...4s FCP STOREX RS2999FCPH3 MT09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 1e Aliases NL 0214e4 3 21 00 00 fa ce 00 21 e1 20 00 00 fa ce 00 21 e1 0 FC4s FCP STOREX RS2999FCPH3 CD09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 e1 Aliases MyAlias1 MyAlias2 NL 0214e8 3 21 00 00 fa ce 04 83 c9 20 00 00 fa ce 04 83 c9 0 FC4s FCP...

Page 371: ...00 21 1e 0 FC4s FCP STOREX RS2999FCPH3 MT09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 1e Device type Physical Target Aliases NL 0214e4 3 21 00 00 fa ce 00 21 e1 20 00 00 fa ce 00 21 e1 0 FC4s FCP STOREX RS2999FCPH3 CD09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 e1 Device type Physical Target Aliases MyAlias1 MyAlias2 N...

Page 372: ... This command has the following operand Examples To display all devices in the fabric followed by all type 8 SCSI FCP devices and all type 5 SCSI FCIP devices nsAllShow type Specify the FC PH type code This operand is optional The valid values for this operand are 0 to 255 Following are two specific FC PH device type codes 8 FCP type device 4 5 FC IP type device Other FC PH types are displayed in ...

Page 373: ...Fabric OS 5 x command reference guide 373 See also nsShow switchShow ...

Page 374: ...he operand is as follows nscamShow Type U for unknown N for N_Port NL for NL_Port Pid The 24 bit Fibre Channel address COS A list of classes of service supported by the device PortName The device s port world wide name WWN NodeName The device s node WWN Permanent Port Name Physical N_Port or NL_Port WWN t Specify to display the device type Of the two device type parts the first part indicates the ...

Page 375: ...bric Port Name 20 02 00 60 69 00 68 19 Permanent Port Name 10 00 00 60 69 00 ab ba Switch entry for 4 state rev owner known v320 0xfffc01 Device list count 0 No entry is found switch admin nscamShow t nscam show for remote switches Switch entry for 2 state rev owner known v430 0xfffc01 Device list count 1 Type Pid COS PortName NodeName N 021200 2 3 10 00 00 60 69 00 ab ba 10 00 00 60 69 00 ab ba F...

Page 376: ...376 Fabric OS commands nsShow switchShow ...

Page 377: ...y registers SCSI inquiry data for FCP target devices FC4s supported IP address IPA Port and node symbolic names Fabric Port Name This is the WWN of the port on the switch to which the device is physically connected Hard address and or port IP address nsShow Type U for unknown N for N_Port NL for NL_Port PID 24 bit Fibre Channel address COS List of classes of service supported by device PortName De...

Page 378: ...registration Register to receive all RSCN requests issued for events detected by the affected Nx_Port SCR 3 Register to receive all RSCN request issued The RSCN request returns all effected N_Port_ID pages t Displays the device type Of the two device type parts the first part indicates the origination of the device Currently four originations are defined Physical Device connected to the Nx_Port us...

Page 379: ...1 1e na FC4s FCP STOREX RS2999FCPH3 MT09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 1e NL 0214e4 3 21 00 00 fa ce 00 21 e1 20 00 00 fa ce 00 21 e1 na FC4s FCP STOREX RS2999FCPH3 CD09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 e1 NL 0214e8 3 21 00 00 fa ce 04 83 c9 20 00 00 fa ce 04 83 c9 na FC4s FCP STOREX RS2999FCPH3 NS...

Page 380: ...s FCP STOREX RS2999FCPH3 MT09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 1e NL 0214e4 3 21 00 00 fa ce 00 21 e1 20 00 00 fa ce 00 21 e1 0 FC4s FCP STOREX RS2999FCPH3 CD09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 e1 NL 0214e8 3 21 00 00 fa ce 04 83 c9 20 00 00 fa ce 04 83 c9 0 FC4s FCP STOREX RS2999FCPH3 NS09 Fabric Por...

Page 381: ...2 d6 Device type NPIV Initiator NL 0214e2 3 21 00 00 fa ce 00 21 1e 20 00 00 fa ce 00 21 1e 0 FC4s FCP STOREX RS2999FCPH3 MT09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 00 00 fa ce 00 21 1e Device type Physical Target NL 0214e4 3 21 00 00 fa ce 00 21 e1 20 00 00 fa ce 00 21 e1 0 FC4s FCP STOREX RS2999FCPH3 CD09 Fabric Port Name 20 04 00 60 69 01 44 22 Permanent Port Name 21 0...

Page 382: ...ode IPA port and node symbolic name local device only fabric port name hard address and or port IP address Operands This command has the following operands nsZoneMember Type U for unknown N for N_Port NL for NL_Port Pid The 24 bit Fibre Channel address COS A list of classes of service supported by the device PortName The device s port world wide name WWN NodeName The device s node WWN Permanent Po...

Page 383: ...0 06 78 Permanent Port Name 10 00 00 00 c9 26 0e ae Device type Physical Initiator NL 0416e2 3 22 00 00 20 37 d9 6b b3 20 00 00 20 37 d9 6b b3 0 FC4s FCP SEAGATE ST318304FC 0005 Fabric Port Name 20 06 00 60 69 50 06 78 Permanent Port Name 22 00 00 20 37 d9 6b b3 Device type Physical Target NL 0416e4 3 22 00 00 20 37 d9 61 ac 20 00 00 20 37 d9 61 ac 0 FC4s FCP SEAGATE ST318304FC 0005 Fabric Port Na...

Page 384: ...ce type Physical Target NL 0416e4 3 22 00 00 20 37 d9 61 ac 20 00 00 20 37 d9 61 ac 0 FC4s FCP SEAGATE ST318304FC 0005 Permanent Port Name 22 00 00 20 37 d9 61 ac Device type Physical Target No remote zoned members switch admin nszonemember a Port 4 Pid 0xb00400 Aliases ix360_131_201_6a Zoned Members 2 devices Pid 0xb00400 Aliases ix360_131_201_6a Pid 0xba1ee8 Aliases trimm101b_3 Port 12 Pid 0xb00...

Page 385: ...min nszonemember u Pid 0xb01ea9 Aliases trimm32b_1 Pid 0xb01eaa Aliases trimm32b_2 Pid 0xb01eab Aliases trimm32b_3 Pid 0xb01eac Aliases trimm32b_4 Pid 0xb01fad Aliases trimm32a_5 Pid 0xb01fae Aliases trimm32a_6 Pid 0xb01fb1 Aliases trimm32a_7 Pid 0xb01fb2 Aliases trimm32a_8 Pid 0xdc2800 Aliases Totally 9 unzoned devices in the fabric ...

Page 386: ... you are prompted to enter the old password and if your entry is valid the new password If a you are changing another user level password you are prompted to enter that user level s old password and if your entry is valid the new password If you are logged in as the root user when changing another user level password you are not prompted to enter the old password The command is disabled until you ...

Page 387: ...in or user You can only specify this operand when you are logged in as root factory or admin If you try to change the password of a user level higher in the hierarchy for example you are admin and attempting to change the root password you are prompted to enter the current password of that level If you try to change the password of a user level lower in the hierarchy you are not prompted to enter ...

Page 388: ...re active If you specify a destination port that is not active this command uses the embedded port as the destination For bladed systems the ingress and egress points are specified as area numbers For nonbladed systems ingress and egress points are specified as ports This agrees with the representation displayed by the switchShow command In addition pathInfo can provide upon request statistics on ...

Page 389: ...of buffer to buffer credit It is an indication of downstream congestion This value reports for multiple time periods displayed in parentheses Note that other commands such as portStatsShow might express this value in units other than milliseconds Extended statistics Extended statistics report variables of general interest They include the following F s Frames per second received or transmitted rep...

Page 390: ...ding whether basic and extended statistics should be included src_portnumber Port or area whose path to the destination domain is sought The default is embedded port 1 For bladed systems the destination is specified as the area otherwise it is the port If the source port is 1 with no additional arguments basic statistics display for the route dst_portnumber Port or area on the destination switch f...

Page 391: ... 8 1G 1000 2 8 8 web228 9 1G 1000 3 6 91 web225 E switch admin pathinfo Max hops 1 127 25 Domain 1 239 1 8 Source port 0 15 1 Destination port 0 255 1 Basic stats yes y no n no y Extended stats yes y no n no y Trace reverse path yes y no n no Source route yes y no n no Timeout 1 30 5 Target port is Embedded Hop In Port Domain ID Name Out Port BW Cost 0 E 9 web226 2 1G 1000 Port E 2 Tx Rx Tx Rx B s...

Page 392: ...1 3 10 web229 12 1G 1000 Port 3 12 Tx Rx Tx Rx B s 1s 36 76 0 0 B s 64s 5 5 5 5 Txcrdz 1s 0 0 Txcrdz 64s 0 0 F s 1s 1 1 0 0 F s 64s 0 0 0 0 Words 240434036 2294316 2119951 2121767 Frames 20025929 54999 162338 56710 Errors 4 0 Hop In Port Domain ID Name Out Port BW Cost 2 14 8 web228 E output truncated ...

Page 393: ...operand Examples To examine a panic dump file by the name panic_dump located under the directory tmp pdShow panic dump file Specify the full path name of a panic dump file This operand is optional switch admin pdshow tmp panic_dump CAUTION Host PLATFORM current is Unknown PLATFORM got from pd file is SW12000 Some results shown may be incorrect and or missing It is best if this command is run on sa...

Page 394: ...394 Fabric OS commands See also portLogDump saveCore ...

Page 395: ...r of words from device B to host A The CRC count equals the total number of CRC errors for both directions Adding a monitor on port 1 specifying 0x010100 as SID and 0X050200 as the DID has a similar effect except the RX and TX counts are interchanged If ISL monitoring is enabled end to end monitors cannot be added to E_Ports Existing end to end monitors on E_Ports are deleted Identical monitors ca...

Page 396: ...r perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor perfClearEEMonitor perfDelEEMonitor perfShowEEMonitor DestID Specify the 3 byte DID destination ID of the destination device It should be in 0xDDAAPP format where DD is domain ID AA is area ID and PP is AL_PA ID For example 0x050200 has a domain ID of 5 an area ID of 2 and an AL_PA ID of 0 SourceID and DestID both cannot ...

Page 397: ...ers is eight per port including user defined filters read filters write filters read write filters SCSI frame monitor and IP frame monitor Operands The operands are as follows Optionally a comma can separate the operands A space is required to separate the operands even when using commas Examples To add an IP monitor to a port perfAddIPMonitor slotnumber For bladed systems only this operand specif...

Page 398: ...398 Fabric OS commands See also perfAddEEMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor ...

Page 399: ...r of filters is eight per port including user defined filters read filters write filters read write filters SCSI frame monitor and IP frame monitor Operands This command has the following operands Optionally a comma can separate the operands A space is required to separate the operands even when using commas Examples To add a SCSI read monitor to a port perfAddReadMonitor slotnumber For bladed sys...

Page 400: ...400 Fabric OS commands See also perfAddEEMonitor perfAddIPMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor ...

Page 401: ... number of filters is eight per port including user defined filters read filters write filters read write filters SCSI frame monitor and IP frame monitor Operands This command has the following operands Optionally a comma can separate the operands A space is required to separate the operands even when using commas Examples To add a SCSI read and write monitor to a port perfAddRWMonitor slotnumber ...

Page 402: ...402 Fabric OS commands See also perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor ...

Page 403: ...per port including user defined filters read filters write filters read write filters SCSI frame monitor and IP frame monitor Operands This command has the following operands Optionally a comma can separate the operands A space is required to separate the operands even when using commas Examples To add a SCSI traffic frame monitor to a port perfAddSCSIMonitor slotnumber For bladed systems only thi...

Page 404: ...404 Fabric OS commands See also perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddUserMonitor perfAddWriteMonitor ...

Page 405: ...ad filters write filters read write filters SCSI frame monitor and IP frame monitor In addition there should be no more than six different offsets for each filter and no more than four different values per offset defined by the user Operands This command has the following operands perfAddUserMonitor slotnumber For bladed systems only this operand specifies the slot number of the port on which the ...

Page 406: ...plied AND ed to frame contents ValueList Specify up to four values that need to be captured from frame contents The ValueList can be either hexadecimal or decimal format SOFx frames are considered a special case The Offset is specified as 0x0 valueList values are specified with 0 SOFf 1 SOFc1 2 SOFi1 3 SOFn1 4 SOFi2 5 SOFn2 6 SOFi3 7 SOFn3 alias Specify a name for this monitor This string truncate...

Page 407: ... filters is eight per port including user defined filters read filters write filters read write filters SCSI frame monitor and IP frame monitor Operands This command has the following operands Optionally a comma can separate the operands A space is required to separate the operands even when using commas Examples To add a SCSI Write command monitor to a port perfAddWriteMonitor slotnumber For blad...

Page 408: ...408 Fabric OS commands See also perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor ...

Page 409: ...he previously saved end to end and filter configuration settings of performance monitoring from nonvolatile memory Operands none Examples To clear the performance monitoring information from nonvolatile memory See also perfCfgRestore perfCfgSave perfCfgClear switch admin perfcfgclear This will clear Performance Monitoring settings in FLASH The RAM settings won t change Do you want to continue yes ...

Page 410: ...tion cleared using the perfCfgClear command rather it restores the configuration on nonvolatile memory Any configuration changes that were not saved are lost using the perfCfgRestore command Operands none Examples To restore the performance monitoring configuration information from nonvolatile memory See also perfCfgClear perfCfgSave perfCfgRestore switch admin perfcfgrestore This will overwrite c...

Page 411: ...ion settings of performance monitoring into nonvolatile memory This enables the performance monitoring configuration to be saved across power cycles Operands none Examples To save the current performance monitoring configuration to firmware See also perfCfgClear perfCfgRestore perfCfgSave switch admin perfcfgsave This will overwrite previously saved Performance Monitoring settings in FLASH Do you ...

Page 412: ... separate the operands even when using commas Examples To clear statistics counters for an end to end monitor perfClearEEMonitor slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switc...

Page 413: ...Fabric OS 5 x command reference guide 413 See also perfAddEEMonitor perfShowEEMonitor perfMonitorClear ...

Page 414: ...te the operands even when using commas Examples To clear statistics counters for a filter based monitor perfClearFilterMonitor slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switchS...

Page 415: ...Fabric OS 5 x command reference guide 415 See also perfAddUserMonitor perfShowFilterMonitor perfMonitorClear ...

Page 416: ...or all AL_PAs on a port See also perfShowAlpaCrc perfClrAlpaCrc slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switchShow for a list of valid ports ALPA Specify the AL_PA address if...

Page 417: ...t or all such monitors See also perfAddEEMonitor perfShowEEMonitor perfDelEEMonitor slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switchShow for a list of valid ports monitorId Spe...

Page 418: ...from the port See also perfAddUserMonitor perfShowFilterMonitor perfDelFilterMonitor slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switchShow for a list of valid ports monitorid Sp...

Page 419: ... performance monitoring help information Synopsis perfhelp Availability all users NOTE This command requires a Performance Monitor license Description Use this command to display the available performance monitoring help commands Operands none perfHelp ...

Page 420: ...EMonitor Show user defined end to end monitors perfSetPortEEMask Set overall mask for E to E monitors perfShowPortEEMask Show the current end to end mask perfAddUserMonitor Add filter based monitor perfAddReadMonitor Add filter based monitor SCSI Read perfAddWriteMonitor Add filter based monitor SCSI Write perfAddRWMonitor Add monitor SCSI Read and Write perfAddSCSIMonitor Add monitor for SCSI fra...

Page 421: ...h can be one of EE end to end FLT filter based or ISL inter switch link These values are case sensitive This operand is required slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switc...

Page 422: ... perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor perfMonitorShow switch admin perfMonitorClear class FLT 1 2 4 Filter based monitor number 4 counters are cleared switch admin perfMonitorClear class FLT 1 2 This will clear ALL filter based monitors counters on port 2 continue yes y no y no y switch admin perfMonitorClear class ISL 1 This will clear ISL monitor on port 1 continue yes y no ...

Page 423: ...ays a snapshot of the traffic at the specified interval For filter based monitors this command can display if no interval operand is specified the following If you do not specify a value for the interval operand this command displays a cumulative count of the traffic detected by the monitor If you specify a value for the interval operand this command displays a snapshot of the traffic at the speci...

Page 424: ... the Tx and Rx counts are in the unit of byte when this operand is specified This operand is optional switch admin perfMonitorShow class EE 4 5 6 perfmonitorshow 53 6 Tx Rx are of bytes and crc is of crc errors 0 1 2 3 4 crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 53m 4 9m 0 53m 4 9m 0 53m 4 9m 0 53m 4 9m 0 53m 0 0 53m 4 4m 0 53m 4 4m 0 53m 4 4m 0 53m 4 4m 0 5...

Page 425: ...0x0000000000000000 4 0x21300 0x21de2 TELNET N A 0x00000004d0bad086 0x0000000067229e87 0x0000000000000000 5 0x11000 0x21fd6 WEB_TOOLS 192 168 169 40 0x00000004d0bade54 0x0000000067229e87 0x0000000000000000 6 0x11000 0x21fe0 WEB_TOOLS 192 168 169 40 0x00000004d0baed41 0x0000000067229e98 0x0000000000000000 switch admin perfMonitorShow class FLT 2 5 6 perfmonitorshow 21 6 0 1 2 3 4 5 6 Frames Frames F...

Page 426: ... N A 0x00000000002c2229 1 SCSI_WR TELNET N A 0x000000000000464a 2 SCSI_RW TELNET N A 0x000000000000fd8c 3 SCSI_RW WEB_TOOLS 192 168 169 40 0x0000000000007ba3 4 SCSI_RW WEB_TOOLS 192 168 169 190 0x0000000000004f0e 5 SCSI_RD WEB_TOOLS 192 168 169 40 0x0000000000002208 6 SCSI_WR WEB_TOOLS 192 168 169 40 0x000000000000033a switch admin perfMonitorShow class ISL 1 1 Total transmit count for this ISL 14...

Page 427: ... EE mask value upon power on is already set When ISL monitoring is enabled EE mask on E_Ports are controlled automatically and existing mask values for E_Ports are over written Operands This command has the following operands perfSetPortEEMask slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Spe...

Page 428: ...tion marks are optional RxSIDMsk represents receiving source ID mask This operand is required RxDIDMsk Specify the destination ID mask in dd aa pp format Quotation marks are optional RxDIDMsk represents receiving destination ID mask This operand is required switch admin perfsetporteemask 1 6 00 00 00 ff ff ff 00 00 ff ff 00 00 Changing EE mask for this port will cause ALL EE monitors on this port ...

Page 429: ...unt is displayed in decimal format Operands This command has the following operands Optionally a comma can separate the operands A space is required to separate the operands even when using commas Examples To display the CRC error count for all AL_PA devices on a port See also perfClrAlpaCrc perfShowAlpaCrc slotnumber For bladed systems only this operand specifies the slot number of the port on wh...

Page 430: ...erands This command has the following operands Optionally a comma can separate the operands A space is required to separate the operands even when using commas perfShowEEMonitor slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added ...

Page 431: ...m 4 5m 0 52m 4 5m 0 52m 4 5m 0 52m 0 0 52m 5 0m 0 52m 5 0m 0 52m 5 0m 0 52m 5 0m 0 52m 0 0 52m 4 5m 0 52m 4 5m 0 52m 4 5m 0 52m 4 5m 0 52m 0 0 52m 4 6m 0 52m 4 6m 0 52m 4 6m 0 52m 4 6m 0 52m 0 switch admin perfshoweemonitor 4 5 There are 7 end to end monitor s defined on port 53 KEY SID DID OWNER_APP OWNER_IP_ADDR TX_COUNT RX_COUNT CRC_COUNT 0 0x21300 0x21dda TELNET N A 0x00000004d0ba9915 0x000000...

Page 432: ...splay filter monitor traffic on a port at an interval of every 6 seconds perfShowFilterMonitor slotnumber For bladed systems only this operand specifies the slot number of the port on which the monitor is to be added followed by a slash portnumber Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switchShow for a list of valid ports in...

Page 433: ...200 750 750 751 550 201 26k 180 692 692 691 512 179 26k 179 696 696 696 517 179 26k 187 720 720 720 533 187 26k 200 722 722 722 522 200 26k 204 717 717 717 513 204 switch admin perfshowfiltermonitor 2 5 There are 7 filter based monitors defined on port 21 KEY ALIAS OWNER_APP OWNER_IP_ADDR FRAME_COUNT 0 SCSI_Frame TELNET N A 0x00000000002c2229 1 SCSI_WR TELNET N A 0x000000000000464a 2 SCSI_RW TELNE...

Page 434: ... 12 fields The fields that are marked on are used to trigger end to end monitors The default value of the EE mask is all fields set to on Operands This command has the following operand perfShowPortEEMask TxSID Domain on TxSID Area on TxSID ALPA on TxDID Domain on TxDID Area on TxDID ALPA on RxSID Domain on RxSID Area on RxSID ALPA on RxDID Domain on RxDID Area on RxDID ALPA on slotnumber For blad...

Page 435: ...ddEEMonitor perfDelEEMonitor perfSetPortEEMask switch admin perfshowporteemask 2 4 The EE mask onport 20 is set by application NONE TxSID Domain on TxSID Area on TxSID ALPA on TxDID Domain on TxDID Area on TxDID ALPA on RxSID Domain on RxSID Area on RxSID ALPA on RxDID Domain on RxDID Area on RxDID ALPA on ...

Page 436: ...ertificate should be obtained offline from Certificate Authority In secure mode this command exits with a warning and does not create PKI objects Operands none Examples To create PKI objects in nonsecure mode If run in secure mode the following error message is displayed See also pkiRemove pkiShow pkiCreate switch admin pkicreate Installing Private Key and Csr Switch key pair and CSR generated Ins...

Page 437: ... remove PKI objects Operands none Examples To remove PKI objects in nonsecure mode If run in secure mode the following error message is displayed See also pkiCreate pkiShow pkiRemove switch admin pkiremove WARNING Removing Pki objects will impair the security functionality of this fibre channel switch If you want secure mode enabled you will need to get the switch certificate again About to remove...

Page 438: ...se this command to display existence of PKI objects such as switch private key private key pass phrase CSR root certificate and switch certificate Operands none Examples To view PKI objects See also pkiCreate pkiRemove pkiShow switch admin pkishow Passphrase Exist Private Key Exist CSR Exist Certificate Empty Root Certificate Exist ...

Page 439: ...port is not an active FL_Port or if it does not have any AL_PA this command displays an error Operands This command has the following operands Examples To display the AL_PAs of a port See also switchShow portAlpaShow slotnumber For bladed systems only specify the slot number of the port to display followed by a slash portnumber Specify the port number to display relative to its slot for bladed sys...

Page 440: ...LongDistance command If the port is not configured in long distance mode certain systems might reserve buffers for the port This field then displays the number of buffers reserved for the port Buffer Usage Displays the actual number of buffers allocate to the port In LD mode the number is determined by by the actual distance and the user specified desired distance configured by the desired_distanc...

Page 441: ...er of the port group to display followed by a slash portnumber Specifies the number of a port associated with the port group to display relative to its slot for bladed systems Use switchShow for a list of valid ports This operand is optional if omitted this command displays the long distance buffer information for all the port groups of the switch In the case where this command displays informatio...

Page 442: ...her SID or DID CAM can be shared among ports in the same quad SID entries All existing source ID entries within the CAM per quad Note that each CAM entry either SID or DID CAM can be shared among ports in the same quad DID entries All existing destination ID entries within the CAM per quad Note that each CAM entry either SID or DID CAM can be among ports in the same quad SID free Total number of f...

Page 443: ...ow Ports of Slot 9 Port SID used DID used SID free DID free 0 0 0 64 512 1 0 0 64 512 2 0 0 64 512 3 0 0 64 512 4 0 0 64 512 5 0 0 64 512 6 0 0 64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 511 10 0 0 63 511 11 1 1 63 511 12 0 0 46 510 13 0 0 46 510 14 0 0 46 510 15 18 2 46 510 output truncated switch user portcamshow 3 2 Area SID used DID used SID entries DID entries 34 3 1 350400 2b2200 2b1200 22040...

Page 444: ...e RSCN to any other end device When RSCN suppression is disabled device change on this port generates RSCN to another end device that is zoned with this one By default RSCN suppression is disabled to all the ports slotnumber For bladed systems only specify the slot number of the port to be configured followed by a slash portnumber Specify the number of the ports to be configured relative to its sl...

Page 445: ... other slots suppressed Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port CreditShare ISL R_RDY Mode RSCN Suppressed ON Persistent Disable where AN AutoNegotiate OFF INVALID LM L0 5 ...

Page 446: ...ts suppressed Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port CreditShare ISL R_RDY Mode RSCN Suppressed Persistent Disable where AN AutoNegotiate OFF INVALID LM L0 5 ...

Page 447: ...show output from other slots suppressed Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port CreditShare ISL R_RDY Mode RSCN Suppressed ON ON ON ON Persistent Disable where AN AutoNegotiate OFF INVALID LM L0 5 ...

Page 448: ...perands This command has the following operands Examples To reset a port to factory defaults See also portCfgEPort portCfgGPort portCfgLongDistance portCfgLPort portCfgPersistentDisable portCfgPersistentEnable portCfgShow portCfgSpeed portCfgTrunkPort portCfgDefault slotnumber For bladed systems only specify the slot number of the port to display followed by a slash portnumber Specify the port num...

Page 449: ...Regardless of how many E_Ports are connected between two switches the maximum routing paths are currently limited to 16 E_Ports Changes made by this command are persistent across switch reboots or power cycles Operands This command has the following operands Examples To disable a port from becoming an E_Port To enable a port to become an E_Port See also portShow switchShow portCfgEPort slotnumber ...

Page 450: ... cycles Operands This command has the following operands Examples To configure a port as a locked G_Port See also configure portCfgLPort portShow switchShow portCfgGPort slotnumber For bladed systems only specify the slot number of the port to be configured followed by a slash portnumber Specify the number of the port to be configured relative to its slot for bladed systems Use switchShow to displ...

Page 451: ...mode ports are not the same zoning drops frames This feature is persistent across reboots and power cycles Use the portCfgShow command to view whether ISL R_RDY mode is enabled on a port NOTE The portCfgISLMode and portCfgLongDistance mode both cannot be enabled at the same time otherwise fabric segmentation occurs Operands This command has the following operands Examples To enable ISL R_RDY mode ...

Page 452: ...452 Fabric OS commands See also portCfgShow ...

Page 453: ...configure the port to be a regular switch port A total of 20 full size frame buffers are reserved for data traffic regardless of the port s operating speed L0 5 Level 0 5 portCfgShow displays the two letter code as LM long distance up to 25 km L1 1 Level 1 long distance up to 50 km L2 2 Level 2 long distance up to 100 km For previously released switches Bloom1 based the number of frames buffers is...

Page 454: ...ack of frame buffers HP StorageWorks SAN Switch 2 8V 2 16V and 2 32 switches and HP StorageWorks Core Switch 2 64 and 2 128 directors do not support buffer limited mode and can have up to four ports per port group The 4 8 4 16 and 4 32 SAN switches and the 4 GB SAN Switch support buffer limited mode and can have up to eight ports per port group On HP StorageWorks 4 256 SAN Director the 4 16 and 4 ...

Page 455: ...portFlags 0x20001 PRESENT LED portType 1 1 portState 2 Offline portPhys 4 No_Light portScn 0 portId 013f00 portWwn 20 3f 00 60 69 00 02 48 Distance super long 100km portSpeed 2Gbps Interrupts 9 Link_failure 0 Frjt 0 Unknown 0 Loss_of_sync 0 Fbsy 0 Lli 9 Loss_of_sig 9 Proc_rqrd 0 Protocol_err 0 Timed_out 0 Invalid_word 0 Rx_flushed 0 Invalid_crc 0 Tx_unavail 0 Delim_err 0 Free_buffer 0 Address_err ...

Page 456: ...rand is optional if omitted this command displays the L_Port conditions for all ports locked_mode Specify 1 to configure the specified port as a locked L_Port Specify 0 to deconfigure the specified port from its previous role as a locked L_Port This operand is required if portnumber is specified private_mode Specify 1 to configure the L_Port as a private L_Port Specify 0 to configure the L_Port as...

Page 457: ... 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port ON Locked G_Port Disabled E_Port ISL R_RDY Mode Persistent Disable where AN AutoNegotiate OFF INVALID switch admin portcfglport output from other slots suppressed Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 458: ...458 Fabric OS commands ...

Page 459: ... does not enable the persistently disabled ports of that blade The persistent switch disable or enable configuration does not alter the persistent disable or enable configurations of the ports within the switch Because the default state of the port is persistently enabled the persistent disable state is cleared by the portCfgDefault command This command is not allowed if the switch is operating in...

Page 460: ...460 Fabric OS commands See also ficoncupset ficoncupshow portCfgDefault portDisable portEnable portCfgPersistentEnable portShow switchShow ...

Page 461: ...tion commands configDefault and portCfgDefault do not modify the persistent enable attribute of a port Operands This command has the following operands When no operand is specified the command reports the current port persistently enabled status for all ports in the switch The value of YES is displayed for ports that are persistently enabled Examples To configure a port as persistently enabled and...

Page 462: ...462 Fabric OS commands See also ficoncupset ficoncupshow ficoncupset ficoncupshow portDisable portDisable portEnable portCfgPersistentDisable portCfgShow portShow switchShow ...

Page 463: ...fgLongDistance command Locked L_Port mode Displays as ON when port is locked to L_Port only or blank when L_Port lock mode is disabled and it behaves as a U_Port This value is set by the portCfgLPort command Locked G_Port mode Displays as ON when port is locked to G_Port only or blank when G_Port lock mode is disabled and it behaves as a U_Port This value is set by the portCfgGPort command Disable...

Page 464: ...is command displays information for all ports switch user portcfgshow Ports of Slot 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port ISL R_RDY Mode RSCN Suppressed Persistent Disable Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN ...

Page 465: ...CfgEPort portCfgGPort portCfgLongDistance portCfgLPort portCfgSpeed portCfgTrunkPort switch user portcfgshow 4 15 Area Number 63 Speed Level AUTO Trunk Port OFF Long Distance OFF VC Link Init OFF Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF ...

Page 466: ...t and the portCfgShow command displays the user desired speed setting for a port Operands This command has the following operands Examples To configure the speed of a port to 2 Gb s See also portCfgShow portShow switchCfgSpeed portCfgSpeed slotnumber For bladed systems only specify the slot number of the port to be configured followed by a slash portnumber Specify a port number to be configured re...

Page 467: ...lies are disabled and reenabled with the new trunk configuration As a result the traffic through these ports might be disrupted for a period of time Operands This command has the following operands Examples To enable a port for trunking See also portCfgShow portShow switchCfgTrunk switchShow portCfgTrunkPort slotnumber For bladed systems only specify the slot number of the port to be configured fo...

Page 468: ...g level and verbose level of port modules Operands This command has the following operands Examples To set debug level and verbose level of port modules See also dbgShow portDebug dbg_lvl Specify the debug level to be set for port modules valid values are 1 to 5 vbs_lvl Specify the verbose level to be set for port modules valid values are 1 to 5 switch admin portdebug 3 4 ...

Page 469: ...transition will be indicated RSCN an SNMP trap a Web pop up window The front panel LED of a disabled port flashes yellow with a two second cycle Operands This command has the following operand Examples To disable a port See also portCfgPersistentDisable portCfgPersistentEnable portEnable portShow switchShow portDisable slotnumber For bladed systems only specify the slot number of the port to be co...

Page 470: ...nd is rejected if the port s switch is disabled the port s blade is not fully enabled faulted powered off or disabled or if the port itself is persistently disabled The front panel LED of an enabled and online port is green Operands This command has the following operand Examples To enable a port See also portCfgPersistentDisable portCfgPersistentEnable portDisable portShow switchShow portEnable s...

Page 471: ...ived enc in Encoding errors inside frames crc err Frames with CRC errors too shrt Frames shorter than minimum too long Frames longer than maximum bad eof Frames with bad end of frame delimiters enc out Encoding error outside of frames disc c3 Class 3 frames discarded link fail Link failures LF1 or LF2 states loss sync Loss of synchronization loss sig Loss of signal frjt Frames rejected with F_RJT ...

Page 472: ... 0 0 14 153 152 0 0 0 0 0 1 8m 0 1 2 0 0 0 15 155 154 0 0 0 0 0 1 7m 0 1 2 0 0 0 48 142 141 0 0 0 0 0 1 8m 0 2 18 0 0 0 49 142 141 0 0 0 0 0 1 8m 0 2 2 0 0 0 50 142 141 0 0 0 0 0 2 1m 0 2 2 0 0 0 51 146 145 0 0 0 0 0 2 0m 0 2 2 0 0 0 52 0 0 0 0 0 0 0 0 0 0 0 1 0 0 53 0 0 0 0 0 0 0 0 0 0 0 1 0 0 54 0 0 0 0 0 0 0 0 0 0 0 1 0 0 55 0 0 0 0 0 0 0 0 0 0 0 1 0 0 56 142 141 0 0 0 0 0 2 1m 0 2 2 0 0 0 57 1...

Page 473: ...2 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 3 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 4 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 5 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 6 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 7 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 8 Offline ...

Page 474: ...RT L_PORT LOGIN NOELP LED ACCEPT 4 8 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 4 9 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 4 10 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 4 11 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 4 12 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 4 13 Online In_Sync PRESENT ACTIVE E_PO...

Page 475: ...switchDisable command before running this command After the command had completed the ATTN LEDs flash amber indicating that the command has finished and exited You can enable the current switch using the switchEnable command to set the ATTN LEDs back to black Operands This command has the following optional operands Examples To test port LEDs See also itemList switchDisable switchEnable portLedTes...

Page 476: ... is disabled portLogClear enables it Certain errors automatically disable the port log to preserve information needed to understand the error new events are not collected so that existing information is not overwritten The following errors disable the port log FCPH EXCHBAD FCPH EXCHFREE NBFSM DUPEPORTSCN UCAST RELICPDB See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages ref...

Page 477: ... Synopsis portlogconfigshow Availability admin Description Use this command to display the current port log configuration Operands none Examples To display the current port log configuration See also portLogResize portLogConfigShow switch admin portlogconfigshow max portlog entries 8192 ...

Page 478: ...ber of lines to be displayed Only the most recent count entries are displayed This operand is optional saved Specify a nonzero value to display the saved port log from the last switch fault See upTime for conditions that cause a fault The operand count is ignored when displaying the saved log This operand is optional portid Specify the port to display All other ports will not be displayed This ope...

Page 479: ...99 tReceive pstate 14 LR2 08 35 27 916 tReceive pstate 14 AC 08 35 28 416 interrupt scn 14 1 08 35 28 433 tFabric ioctl 14 90 101d9910 0 08 35 28 433 tFabric Tx 14 164 02fffffd 00fffffd 0005ffff 10000000 08 35 28 433 tReceive Rx 14 0 c0fffffd 00fffffd 00050006 08 35 28 433 tReceive Rx 14 164 03fffffd 00fffffd 00050006 02000000 08 35 28 433 tTransmit Tx 14 0 c0fffffd 00fffffd 00050006 ...

Page 480: ...g message displays as the first line See portLogClear command for more information WARNING port log is disabled See the HP StorageWorks Fabric OS 5 x procedures user guide for more information Operands This command has the following operand Examples To display the port log dump for a port portLogDumpPort portid Specify the area number of port to display If a port area number is specified all other...

Page 481: ... 14 LR1 08 35 28 466 tReceive pstate 14 LR3 08 35 28 466 tReceive pstate 14 AC 08 35 28 483 tFabric Tx 14 96 02fffffd 00fffffd 0006ffff 11100060 08 35 28 483 tReceive Rx 14 0 c0fffffd 00fffffd 00060007 08 35 28 483 tReceive Rx 14 96 03fffffd 00fffffd 00060007 02100060 08 35 28 483 tTransmit Tx 14 0 c0fffffd 00fffffd 00060007 08 35 28 483 tFabric ioctl 14 a1 0 0 08 35 28 483 tFabric scn 14 5 ...

Page 482: ...d indicates if the port log for that event ID is disabled 1 or enabled 0 Operands none Examples Display information about port log events portLogEventShow switch admin portlogeventshow ID Event Name Disabled 1 start 0 2 disable 0 3 enable 0 4 ioctl 0 5 Tx 0 6 Tx1 0 7 Tx2 0 8 Tx3 0 9 Rx 0 10 Rx1 0 11 Rx2 0 12 Rx3 0 13 stats 0 14 scn 0 15 pstate 0 16 reject 0 17 busy 0 18 ctin 0 19 ctout 0 20 errlog...

Page 483: ...rfsm 0 25 timer 0 26 sn 0 27 fcin 0 28 fcout 0 29 read 0 30 write 0 31 err 0 32 frame 0 33 msRemQ 0 34 msRemR 0 35 nsRemQ 0 36 nsRemR 0 37 rscn 0 38 state 0 39 xalloc 0 40 xfree 0 41 xerr 0 42 xstate 0 43 seq 0 44 seqst 0 45 iu 0 46 payload 0 47 zone 0 48 cmd 0 49 event 0 50 msg 0 51 switch 0 52 ficonq 0 53 routing 0 ...

Page 484: ...to fabric F_Port ff PLOGI process login to specific N_Ports or well known address such as name server fd FDISC virtual N_Port login PID The port s 24 bit D_ID WWN The port s world wide name credit The credit for this login as appropriate This is BB buffer to buffer credit for FLOGIs and EE end to end credit for PLOGIs df_sz The default frame size for this login cos Class of services supported This...

Page 485: ...mation for port 23 See also fcpProbeShow portShow switch admin portloginshow 23 Type PID world wide name credit df_sz cos fe 201700 21 00 00 e0 8b 05 a3 c9 3 2048 8 scr 1 ff 201700 21 00 00 e0 8b 05 a3 c9 0 0 8 d_id FFFC20 ff 201700 21 00 00 e0 8b 05 a3 c9 0 0 8 d_id FFFFFC ...

Page 486: ...min Description Use this command to set or clear the debug_pdisc_flag Operands This command has the following operand Examples To set the debug_pdisc_flag See also none portLogPdisc lvl Specify either 0 to clear the flag or 1 to set the debug_pdisc_flag switch admin portlogpdisc 1 PDISC log setting 1 ...

Page 487: ...r the port log for various ports is enabled or disabled 1 in the right column indicates port log for that port is disabled and 0 indicates port log for that port is enabled Operands none Examples To disable the information about the port log settings portLogPortShow switch admin portLogPortShow Port Disabled 0 1 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 continued on next pa...

Page 488: ...488 Fabric OS commands See also portLogEventShow portLogReset portLogTypeDisable portLogTypeEnable 16 0 17 0 18 1 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 ...

Page 489: ...opsis portlogreset Availability admin Description Use this command to enable the port log facility See portLogClear for events that might disable the port log facility Operands none Examples To enable the port log See also portLogPortShow portLogReset switch admin portlogreset ...

Page 490: ...ecified number of entries If num_entries is less than the already configured port log size no change is effected Operands This command has the following operand Examples To resize the port log See also portLogConfigShow portLogResize num_entries Specifies the number of entries to which portlog needs to be resized The valid range of values is 8 192 to 16 384 switch admin portlogresize 12288 ...

Page 491: ...ollowing information displays for each log entry portLogShow Time Displays the event date and time in milliseconds The clock resolution is 16 milliseconds Task Displays the name of the internal switch procedure that logged the event interrupt if the event was logged in interrupt context or unknown if the task no longer exists Event Displays the task event that generated log entry Possible events i...

Page 492: ...d size scn New state see state codes below pstate New physical state see pstate codes below ctin The CT subtype fc Simple Name Server f8 Alias Server ctout Same as ctin above errlog Error level see errModuleShow loopscn Current loop state during loop initialization possible values are OLP Offline disconnected or nonparticipating LIP FL_Port entered INITIALIZING or OPEN_INIT state LIM LISM complete...

Page 493: ...sents the first and second words of the CT payload if applicable as specified in A If B is a reject argument 1 contains the CT reject reason and explanation code errlog Error type see errModuleShow loopscn The meaning further depends on each loop state OLP Offline reason code usually zero LIP Reason code for LIPs initiated by FL_Port if the code value is 800x x 1 0xc see below or the lower two byt...

Page 494: ...p when LIPs received in OLD_PORT AC state 8008 Restart loop if loop not empty but E_Port loopback 8009 LIP as requested by the LINIT ELS received 800a LIP as requested by the LPC ELS received 800b Restart loop for QuickLoop looplet setup 800c Restart loop for QuickLoop looplet re initialization INIT Start negotiation NM Negotiate master WS Wait for signal NF Negotiation follow NC Negotiation compl...

Page 495: ...000000 00000001 17 05 30 507 PORT Rx 3 40 02fffffd 00fffffd 08ffffff 14000000 17 05 30 507 PORT Tx 3 0 c0fffffd 00fffffd 08ff0e05 17 05 30 508 PORT debug 3 00c0ffee 00fd0148 00000000 00000001 17 05 31 081 PORT Tx 0 40 02fffffd 00fffffd 0e06ffff 14000000 17 05 31 082 PORT debug 0 00c0ffee 00fd0188 14000000 00000001 17 05 31 084 PORT Rx 0 0 c0fffffd 00fffffd 0e060902 17 05 31 772 PORT Tx 1 40 02ffff...

Page 496: ...14 portLogShowPort portid Specify a nonzero value that specifies which port appears switch user portLogShowPort 14 time task event port cmd args 08 35 28 483 tFabric scn 14 0 08 35 27 899 tShell pstate 14 OL1 08 35 27 899 tReceive pstate 14 LR2 08 35 27 916 tReceive pstate 14 AC 08 35 28 416 interrupt scn 14 1 08 35 28 433 tFabric ioctl 14 90 101d9910 0 08 35 28 433 tFabric Tx 14 164 02fffffd 00ff...

Page 497: ... 14 96 02fffffd 00fffffd 0006ffff 11100060 08 35 28 483 tReceive Rx 14 0 c0fffffd 00fffffd 00060007 08 35 28 483 tReceive Rx 14 96 03fffffd 00fffffd 00060007 02100060 08 35 28 483 tTransmit Tx 14 0 c0fffffd 00fffffd 00060007 08 35 28 483 tFabric ioctl 14 a1 0 0 08 35 28 483 tFabric scn 14 5 output truncated ...

Page 498: ...rt log type Operands This command has the following operand Examples To disable event 2 from reporting to the port log See also portLogEventShow portLogTypeEnable portLogTypeDisable id Specify a nonzero value that corresponds to the port log type to be disabled The values corresponding to different log types can be obtained by running portLogEventShow switch admin portlogtypedisable 2 ...

Page 499: ...specified port log type Operands This command has the following operand Examples To enable event 2 to report to the port log See also portLogEventShow portLogTypeDisable portLogTypeEnable id Specify a nonzero value that corresponds to the port log type to be enabled The values corresponding to different log types can be obtained by running portLogEventShow switch admin portlogtypeenable 2 ...

Page 500: ...g BadEOF Enc_out BadOrdSet DiscC3 6 Check if the transmit receive or class 3 receiver counters are stuck at some value 7 Check if the number of frames transmitted is not equal to the number of frames received 8 Repeat step 2 through step 7 for all ports present until The number of frames or passcount requested is reached All ports are marked bad At each pass the frame is created from a different d...

Page 501: ... upon the loopback mode selected When speed modes 5 through 8 are used with cables they must be connected even to odd or the test will fail 0 Runs test at 1 Gb s 2 Gb s and 4 Gb s 1 Runs test at 1 Gb s 2 Runs test at 2 Gb s Bloom default 4 Runs test at 4 Gb s Condor default For lb_mode set to 0 or 1 the following speed modes are available to test the speed negotiation 3 Set all even ports speed fo...

Page 502: ...detected DATA ERRSTAT INIT PORTDIED STATS TIMEOUT XMIT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portRegTest spinSilk sramRetentionTest ...

Page 503: ...t value by executing the portName command with the second operand a null string Like all other configurable port attributes port name persists across reboots and power cycles It will not be affected by configDefault command but it will be cleared by portCfgDefault Operands This command has the following operands Without operands the port names of all ports present are displayed Examples To name to...

Page 504: ...504 Fabric OS commands portCfgDefault portShow ...

Page 505: ...transmitted per interval Throughput values are displayed as either bytes kilobytes k megabytes m or gigabytes g Values are always rounded down Operands This command has the following operand Examples To display port throughput for a switch See also portStatsShow portPerfShow interval Specify the interval in seconds between each sample The default is one second This operand is optional switch user ...

Page 506: ...ested with the following patterns Repeat these steps until all ASIC SRAMs and registers are tested Operands This command has the following operands portRegTest 0x0001 0x0002 0x0004 0x0008 0x0010 0x0020 0x0040 0x0080 0x0100 0x0200 0x0400 0x0800 0x1000 0x2000 0x4000 0x8000 slot slotnumber Specify the slot number on which the diagnostic operates The ports specified will be relative to this slot numbe...

Page 507: ...s BUS_TIMEOUT REGERR REGERR_UNRST See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest spinSilk sramRetentionTest switch admin portregtest ports 1 0 1 15 Running Port Register Test Test Complete portregtest Pass 1 of 1 Duration 0 hr 0 min ...

Page 508: ...t least one entry which routes unicast frames destined to the embedded port value 0x10000 of the local domain Internal unicast routing table Displays how the specified port forward unicast frames to locally attache Nx_Ports in the following format area_number ports_bitmap area_number represents the area number of a device or set of looped devices attached to the local switch The format of ports_bi...

Page 509: ... for a port See also bcastShow fabricShow switchShow topologyShow uRouteShow switch user portrouteshow 4 15 port address ID 0x02bf00 external unicast routing table 1 0x4 vc 3 2 0x10000 vc 0 internal unicast routing table 60 0x8000 vc 2 63 0x1000 vc 5 broadcast routing table 0x10000 ...

Page 510: ...ng security whichever occurs last States include None FCAP DHCHP No authentication was done FCAP authentication was done DH CHAP authentication was done It also displays the DH group and hash used for authentication portDisableReason The reason that a port has been disabled if it has not been disabled by portDisable or portCfgPersistentDisable portCFlags Port control flags portFlags Bit map of por...

Page 511: ...N portWwn of devices connected Port WWNs of connected devices Distance The port s long distance level In case of LD mode the user configured limit and actual distances also are displayed See portCfgLongDistance portSpeed The port s fixed speed 1 2 or 4 Gb s or negotiated speed N1 N2 or N4 Gb s Interrupts Total number of interrupts Unknown Interrupts that are not counted elsewhere Lli Low level int...

Page 512: ...This command has the following operands Suspended Transmission suspended interrupts Parity_err Central memory parity errors 2_parity_err Secondary Tx parity errors CMI_bus_err Control message interface errors Table 17 portShow display fields continued Field Description slotnumber For bladed systems only specify the slot number of the port to be configured followed by a slash portnumber Specify a p...

Page 513: ...tType 10 0 portState 1 Online portPhys 6 In_Sync portScn 16 E_Port Trunk port port generation number 0 portId 012f00 portIfId 43320010 portWwn 20 2f 00 60 69 e4 20 42 portWwn of device s connected None Distance normal portSpeed N4Gbps Interrupts 0 Link_failure 0 Frjt 0 Unknown 0 Loss_of_sync 3 Fbsy 0 Lli 15 Loss_of_sig 2 Proc_rqrd 0 Protocol_err 0 Timed_out 0 Invalid_word 0 Rx_flushed 0 Invalid_cr...

Page 514: ...64_rdy_pri Time R_RDY high priority tim64_txcrd_z Time BB_credit zero er64_enc_in Encoding errors inside of frames er64_crc Frames with CRC errors er64_trunc Frames shorter than minimum er64_toolong Frames longer than maximum er_bad_eof Frames with bad end of frame er64_enc_out Encoding error outside of frames er64_disc_c3 Class 3 frames discarded stat64_rateTxFrame Tx frame rate fr sec stat64_rat...

Page 515: ...4_frx 0 top_int Frames received 73 bottom_int Frames received stat64_c2_frx 0 top_int Class 2 frames received 0 bottom_int Class 2 frames received stat64_c3_frx 0 top_int Class 3 frames received 37 bottom_int Class 3 frames received stat64_lc_rx 0 top_int Link control frames received 8 bottom_int Link control frames received stat64_mc_rx 0 top_int Multicast frames received 0 bottom_int Multicast f...

Page 516: ...lass 3 frames discarded stat64_rateTxFrame 17 Tx frame rate fr sec stat64_rateRxFrame 17 Rx frame rate fr sec stat64_rateTxPeakFrame 17 Tx peak frame rate fr sec stat64_rateRxPeakFrame 17 Rx peak frame rate fr sec stat64_rateTxByte 79 Tx Byte rate bytes sec stat64_rateRxByte 371 Rx Byte rate Bytes sec stat64_rateTxPeakByte 79 Tx peak Byte rate Bytes sec stat64_rateRxPeakByte 371 Rx peak Byte rate ...

Page 517: ...lso clears the hardware statistics for associated ports in the target port quad For platforms with a Condor based ASIC the command clears the hardware statistics only on the port designated Operands This command has the following operands Examples To clear the statistics for a port See also portStats64Show portStatsClear slotnumber For bladed systems only specify the slot number of the port to be ...

Page 518: ...t_mc_tx Multicast frames transmitted tim_rdy_pri Time R_RDY high priority tim_txcrd_z Time BB_credit zero er_enc_in Encoding errors inside frames er_crc Frames with CRC errors er_trunc Frames shorter than minimum er_toolong Frames longer than maximum er_bad_eof Frames with bad end of frame er_enc_out Encoding error outside frames er_bad_os Invalid ordered set platform and port specific er_c3_timeo...

Page 519: ...cies stopped due to starvation fl_tenancy Number of times FL_Port had loop tenancy nl_tenancy Number of times NL_Port had loop tenancy frame_nozone Frames rejected due to zone protection slotnumber For bladed systems only specify the slot number of the port to be configured followed by a slash portnumber Specify a port number to be configured relative to its slot for bladed systems Use switchShow ...

Page 520: ... 0 Frames shorter than minimum er_toolong 0 Frames longer than maximum er_bad_eof 0 Frames with bad end of frame er_enc_out 8600353 Encoding error outside of frames er_disc_c3 0 Class 3 frames discarded open 16 loop_open transfer 16 loop_transfer opened 16 FL_Port opened starve_stop 0 tenancies stopped due to starvation fl_tenancy 3277 number of times FL has the tenancy nl_tenancy 11 number of tim...

Page 521: ...the configuration database displayed by configShow and configUpload Operands This command has the following operands Examples To swaps area numbers between a pair of ports portSwap slotnumber1 For bladed systems only specify the slot number of the first port whose area number is to be swapped followed by a slash portnumber1 Specify a port number to be configured relative to its slot for bladed sys...

Page 522: ...522 Fabric OS commands See also portDisable portEnable portShow portSwapDisable portSwapEnable portSwapShow switchShow ...

Page 523: ... used after this feature is disabled The enabled state of the portswap feature is persistent across reboots and power cycles NOTE Enabling or disabling the portswap feature does not effect previously performed portswap operations Operands none Examples To disable the portswap feature See also portDisable portEnable portShow portSwapEnable portSwapShow switchShow portSwapDisable switch admin portsw...

Page 524: ...re is first enabled with this command The enabled state of the portswap feature is persistent across reboots and power cycles NOTE Enabling or disabling the portswap feature does not effect previously performed portswap operations Operands none Examples To enable the portswap feature See also portDisable portEnable portShow portSwapDisable portSwapShow switchShow portSwapEnable switch admin portsw...

Page 525: ...whose area number ID different from the default area number The default area number of a port is the same as its switch port number Operands none Examples To display the state of the portswap feature and information for ports whose area numbers have been swapped See also portDisable portEnable portShow portSwap portSwapDisable portSwapEnable switchShow portSwapShow switch admin portswapshow PortSw...

Page 526: ...device port using a short wavelength cable a long wavelength port is connected to a long wavelength port and a copper port is connected to a copper port Only one frame is transmitted and received at a time The port LEDs flicker green while the test is running The following port types are supported E_Ports F_Ports must support ELS ECHO L_Ports N N loopback ports This command will not run on any oth...

Page 527: ...iteration to 0 will set the portTest into timeout mode The default value is 0 pattern Specify the pattern of the test packets payload Twenty types of predefined patterns are provided with the test Use the dataTypeShow command to view the types of patterns that are supported with portTest dataTypeShow displays the pattern names the number to use to specify for each pattern type and an example of ea...

Page 528: ...rts asked to test ALL_PORTS ALL_E_PORTS ALL_L_PORTS ALL_F_PORTS ALL_LB_PORTS or SINGLE_PORT Pattern used in testing Seed used in testing User delay value Total iteration asked to test Current test iteration Total fails on this test Consecutive fails on this test portTest start time portTest stop time Timeout value Error code if any Operands The following operands are required portTestShow ports it...

Page 529: ...t loopPortTest portLoopbackTest portTest spinFab stopPortTest switch admin porttestshow 1 Port 1 PASS PortType OTHER PortState NO TEST PortInternalState INIT PortTypeToTest NO_TEST Pattern 0x0 Seed 0x0 UserDelay 0 TotalIteration 0 CurrentIteration 0 TotalFail 0 ConsecutiveFail 0 StartTime NONE StopTime NONE Timeout 0 ErrorCode 0 ...

Page 530: ...ed system no processing of the power off list can be done This is because the lack of power causes the CP boards processors to cease execution of the firmware In this situation all operation of the system terminates immediately However if the system is running on two power supplies this is not recommended and one goes into a predicted fail state in which the power supply is still supplying power t...

Page 531: ... powered off 1 10 10 1 2nd slot to be powered off 2 10 9 2 continued on next page 3rd slot to be powered off 3 10 8 3 4th slot to be powered off 4 10 7 4 5th slot to be powered off 7 10 7 10 6th slot to be powered off 7 9 8 9 7th slot to be powered off 7 8 8 8 8th slot to be powered off 7 7 7 7 Old POL New POL Power Off Order 10 1 1st 9 2 2nd 8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Procee...

Page 532: ...532 Fabric OS commands slotPowerOff slotPowerOn slotShow ...

Page 533: ...o power a fully loaded system no processing of the power off list can be done This is because the lack of power causes the CP boards processors to cease execution of the firmware In this situation all operation of the system terminates immediately However if the system is running on two power supplies this is not recommended and one goes into a predicted fail state in which the power supply is sti...

Page 534: ...534 Fabric OS commands See also chassisShow powerOffListShow psShow slotPowerOff slotPowerOn slotShow ...

Page 535: ...ower supply functioning correctly absent Power supply not present unknown Unknown power supply unit installed predicting failure Power supply is present but predicting failure faulty Power supply present but faulty no power cable power switch turned off fuse blown or other internal error switch admin psShow Power Supply 1 is OK DELTA DPS 1001AB 1E 23000000601 S1 IXD0111000088 Power Supply 2 is fau...

Page 536: ...536 Fabric OS commands See also chassisShow fanShow ...

Page 537: ...st be defined with WWNs Zone alias names that are defined by domain and port number or AL_PA are not accepted as members of the QuickLoop NOTE When security is enabled this command can be issued only from the primary FCS switch Use this command only with Fabric OS 3 x systems in the fabric QuickLoop is not supported in Fabric OS 5 x Operands The following operands are required Examples To add an a...

Page 538: ...all QuickLoops defined in the configuration must resolve to a maximum of two switch worldwide names Zone alias names entered as members of this QuickLoop must be defined with WWNs Zone alias names that are defined by domain and port number or AL_PA are not accepted as members of the QuickLoop NOTE When security is enabled this command can be issued only from the primary FCS switch Use this command...

Page 539: ...nce guide 539 Examples To create two QuickLoops a single switch and one dual switch See also qloopAdd qloopDelete qloopRemove qloopShow switch admin qloopCreate qlp1 10 00 00 60 69 00 60 11 switch admin qloopCreate qlp2 wwn2 wwn3 ...

Page 540: ...n volatile memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Use this command only with Fabric OS 3 x systems in the fabric QuickLoop is not supported in Fabric OS 5 x Operands The following operand is required Exa...

Page 541: ...iguration must resolve to one or two switch worldwide names This command changes the Defined Configuration For the change to be preserved across switch reboots it must be saved to non volatile memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only...

Page 542: ...542 Fabric OS commands See also qloopAdd qloopCreate qloopDelete qloopShow ...

Page 543: ...For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security is enabled this command can be issued only from the primary FCS switch Use this command only with Fabric OS 3 x systems in the fabric QuickLoop is not suppo...

Page 544: ...les To display all QuickLoops beginning with the letter q See also qloopAdd qloopCreate qloopDelete qloopRemove switch admin qloopshow q qloop qlp1 10 00 00 60 69 00 60 11 10 00 00 60 69 00 30 02 qloop qlp2 10 00 00 60 69 00 60 13 ...

Page 545: ...output produced by shell commands displays all asynchronous output produced by other tasks suppresses This is useful when driving a telnet session through a script that might not expect any asynchronous output Operands The following operand is optional The current value appears if no operand is specified Examples To display the current mode and then set it to off See also none quietMode mode 0 cle...

Page 546: ...e this command to display whether RCS is enabled If rcsDisabled 0 appears RCS is enabled rcsDisabled 1 appears if RCS is disabled NOTE This command can be issued on Fabric OS v4 1 x and above and v5 x FCS switch in the fabric Operands none Examples To display the RCS status See also none rcsDisabled switch admin rcsDisabled rcsDisabled 0 ...

Page 547: ...e system are entirely shut down and all Fibre Channel ports become inactive until the system restarts When this command is issued on the active CP of a dual CP system the active CP reboots the standby CP takes over as the active CP and all Fibre Channel ports become inactive until the new active CP reinitializes these ports If this switch is part of a fabric reboot the switch so that the remaining...

Page 548: ...amic Load Sharing dlsSet Turn on Dynamic Load Sharing dlsShow Print state of Dynamic Load Sharing fspfShow Print FSPF global information interfaceShow Print FSPF interface information iodReset Turn off In Order Delivery iodSet Turn on In Order Delivery iodShow Print state of In Order Delivery linkCost Set or print the FSPF cost of a link LSDbShow Print Link State Database entry nbrStateShow Print ...

Page 549: ...the u option d remote_directory Specify the name of the remote directory into which the core files are copied The directory will be created if it does not already exist It is assumed that the user has sufficient privilege to create files at this location f core file directory list Specify a list of the core file directories to transfer to a remote site This list can be comma separated directory li...

Page 550: ...t core_files nsd switch admin savecore r core_files panic r core_files zoned mnt core_files nsd Removing core_files panic Removing core_files zoned Removing mnt core_files nsd switch admin savecore R removing core files under core_files panic removing core files under core_files zoned removing core files under mnt core_files nsd removing core files under mnt core_files panic switch admin savecore ...

Page 551: ...1 12 kB 382 53 B s Files transferred successfully switch admin savecore following 1 directories contains core files 0 mnt core_files panic Welcome to core files management utility Menu 1 or R Remove all core files 2 or F FTP all core files 3 or r Remove marked files 4 or f FTP marked files 5 or m Mark Files for action 6 or u Un Mark Files for action 9 or e Exit Your choice 1 mnt core_files panic Y...

Page 552: ...ll core files 2 or F FTP all core files 3 or r Remove marked files 4 or f FTP marked files 5 or m Mark Files for action 6 or u Un Mark Files for action 9 or e Exit Your choice F core_files zoned You have opted to FTP these core files Please confirm Y N y Destination IP Address 192 168 10 10 User Name anonymous jsmith Remote Directory brcd Password core_files zoned core 8323 1 12 kB 382 40 B s File...

Page 553: ... Un Mark Files for action 9 or e Exit Your choice m Enter File Number to mark 1 Enter CR To Continue following 2 directories contains core files 0 core_files nsd 1 core_files zoned Welcome to core files management utility Menu 1 or R Remove all core files 2 or F FTP all core files 3 or r Remove marked files 4 or f FTP marked files 5 or m Mark Files for action 6 or u Un Mark Files for action 9 or e...

Page 554: ...554 Fabric OS commands See also none ...

Page 555: ...is command is intended strictly for debugging purposes by technical support staff The information displayed might not be supported between releases and is subject to change arbitrarily NOTE This command must be issued in secure mode Operands none Examples To display the size of the active security database See also secDefineSize secGlobalShow secActiveSize switch admin secactivesize Size of securi...

Page 556: ...uest The configuration applies to a switch instance only NOTE A security license is required to run this command in nonsecure as well as secure mode Operands The operands are as follows Examples To list the shared secret WWN secAuthSecret show Lists the WWNs to which shared secret is configured set Sets shared secrets with a WWN remove wwn domain sw name Removes the specified WWN entry from the da...

Page 557: ...e channel for setting secrets Using an insecure channel is not safe and can compromise secrets Following inputs should be specified for each entry 1 WWN for which secret is being set up 2 Peer secret The secret of the peer that authenticates to peer 3 Local secret The local secret that authenticates peer Press Enter to start setting up shared secrets Enter WWN Domain or switch name Leave blank whe...

Page 558: ...gment from the fabric Re enter peer secret Enter local secret Re enter local secret Enter WWN Domain or switch name Leave blank when done Are you done yes y no n no y Saving data to key store Done switch admin secAuthSecret remove all This command deletes database of DH CHAP secret keys If a fabric requires authentication deleting this database may cause switch to segment from the fabric Do want t...

Page 559: ...certificate file name Enable secure protocols The following is the usage statement for the utility secCertUtil seccertutil delcsr Delete CSR seccertutil delete file name Delete certificate seccertutil export Export CSR seccertutil genkey Generate a new public private key pair seccertutil gencsr Generate a new CSR seccertutil import config cacert config swcert enable https import config swcert Conf...

Page 560: ...ting existing CSR and all other certificates gencsr Generates a new CSR for the switch This is second step for setting up third party certificates in the switch To generate a CSR the admin must answer a series of questions prompted by this option Once all questions are answered a CSR is generated and placed in a file named ip_address csr The ip_address is the IP address of the switch delcsr Delete...

Page 561: ...R ARE YOU SURE yes y no n no y switch admin seccertutil import Select protocol ftp or scp ftp Enter IP address ip address Enter remote directory dir name where certificate is stored Enter certificate name must have crt or pem suffix filename Enter Login Name login Enter Password password Success imported certificate certificate file name switch admin seccertutil import config swcert enable https S...

Page 562: ...562 Fabric OS commands To display contents of a certificate See also none switch admin seccertutil show certificate file name ...

Page 563: ... This command is intended strictly for debugging purposes by technical support staff The information displayed might not be supported between releases and is subject to change arbitrarily NOTE This command must be issued in secure mode Operands none Examples To display the size of the defined security database See also secActiveSize secGlobalShow secDefineSize switch admin secdefinesize Size of se...

Page 564: ...plays the world wide name of the switch DId Displays the domain of the switch Status Displays the security state of the switch Ready This switch is in a stable state Busy This switch is updating its security database Error This switch s security database is inconsistent with the primary FCS Enet IP Addr Displays the Ethernet IP address Name Displays the switch name NoResp Displays if the switch di...

Page 565: ...Fabric OS 5 x command reference guide 565 See also secPolicyDump secPolicyShow ...

Page 566: ...rmer backup FCS switch becomes the new primary FCS switch in the fabric The purpose of this command is to recover from a scenario in which all available access to the primary FCS switch is lost such as the Ethernet and serial connections Operands none Examples To enable a backup FCS switch to take over as the primary FCS switch See also secFabricShow secModeDisable secModeShow secFCSFailover switc...

Page 567: ...ersion and general information The current status of the RCS transaction The active and defined sizes of the security database This command is intended strictly for debugging purposes by technical support staff only The information displayed might not be supported between releases and is subject to change arbitrarily NOTE This command must be issued when secure mode is enabled Operands none Exampl...

Page 568: ...568 Fabric OS commands Displays information about security commands Synopsis sechelp Availability all users Description Use this command to display a list of security commands Operands none secHelp ...

Page 569: ... secModeDisable Disables secure mode secModeShow Displays whether secure mode is enabled or disabled secNonFCSPasswd Sets the admin passwd for non FCS switches secPolicyAbort Aborts changes to defined policy secPolicyActivate Activates all policy sets secPolicyAdd Adds members to an existing policy secPolicyCreate Creates a new policy secPolicyDelete Deletes an existing policy secPolicyFCSMove Mov...

Page 570: ...mand deletes both the defined and active security database This command can be issued only in secure mode and only from the primary FCS switch Operands none Examples To disable security mode See also secFabricShow secModeShow secModeDisable primaryfcs admin secmodedisable Please enter current admin account password Warning About to disable security ARE YOU SURE yes y no n no y ...

Page 571: ...ccount passwords on all FCS switches Resetting the admin and user account passwords on all non FCS switches Disabling the root and factory accounts on all non FCS switches in the fabric The administrator is prompted to enter new passwords for the following accounts factory root admin user non FCS admin The prompts do not appear if the administrator chooses to use the passwords on the primary FCS w...

Page 572: ...esent in the fabric If a member is specified by domain or switch name the switch must be in the fabric or the command fails If the list of FCS switches is not specified the session becomes interactive and the user is prompted to enter FCS members currentpwd Use the current passwords of the switch the command is run on the primary FCS switch for root factory admin and user accounts Non FCS admin ac...

Page 573: ...fied as the primary FCS switch fcsprimary admin secModeEnable quickmode Your use of the certificate based security features of the software installed on this equipment is subject to the End User License Agreement provided with the equipment and the Certification Practices Statement which you may review at http www switchkeyactivation com cps By using these security features you are consenting to b...

Page 574: ... from which you obtained this software and do not use these security features Do you agree to these terms yes y no n no y This command requires Switch Certificate Security license and Zoning license to be installed on every switch in the fabric PLEASE NOTE On successful completion of this command login sessions may be closed and some switches may go through a reboot to form a secure fabric This is...

Page 575: ...when done Are you done yes y no n no y Is the new FCS list correct yes y no n no y Please enter current admin account password Warning Access to the Root and Factory accounts may be required for proper support of the switch Please ensure the Root and Factory passwords are documented in a secure location Recovery of a lost Root or Factory password will result in fabric downtime Changing password fo...

Page 576: ... consenting to be bound by the terms of these documents If you do not agree to the terms of these documents promptly contact the entity from which you obtained this software and do not use these security features Do you agree to these terms yes y no n no y This command requires Switch Certificate Security license and Zoning license to be installed on every switch in the fabric PLEASE NOTE On succe...

Page 577: ...e and time of the security database FCS switches Displays a list of FCS switches Primary Displays whether the switch is a primary FCS or backup FCS WWN Displays the WWN of the FCS switch DID Displays the domain of the FCS switch swName Displays the alias name of the FCS switch This command can be issued on any switch in a fabric Operands none Examples To display the current security mode of a fabr...

Page 578: ... and can consist of any combination of alphanumeric characters This command can be issued only in secure mode and only from the primary FCS switch NOTE Ensure no non FCS admin users are logged in when this command is executed otherwise users on non FCS switch sessions terminate Operands none Examples To set the admin password for all non FCS switches in the fabric See also passwd secModeDisable se...

Page 579: ... saved to flash memory NOTE This command can be issued only in secure mode and only from the primary FCS switch Operands none Examples To abort all changes that have not been saved to flash memory See also secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPolicyRemove secPolicySave secStatsShow secPolicyAbort primaryfcs admin secpolicyabort Unsaved data has been abort...

Page 580: ...icy set NOTE This command can be issued only in secure mode and only from the primary FCS switch Operands none Examples To activate the defined security policy set to all switches in the fabric See also secPolicyAbort secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPolicyRemove secPolicySave secStatsShow secPolicyActivate primaryfcs admin secpolicyactivate About to overwrite the curr...

Page 581: ...ss control list for that management method When security is first enabled using the command only the FCS_POLICY exists Before a policy is created there is no enforcement for that management method all access is granted After a policy has been created and a member has been added to the policy that policy becomes closed to all access except from included members If all members are then deleted from ...

Page 582: ...r defined characters These characters do not have to be capitalized like regular policy names but they are case sensitive member Specify a list of member switches for the security policy The members must be enclosed in quotation marks and separated by semicolons Depending on the policy type members can be specified using IP address WWN domain switch name or other IP Address Member Policy Types The...

Page 583: ...witch and port combination must be in the following format switch port switch can be specified using WWN domain or switch name port can be specified by port numbers separated by commas and enclosed in either brackets or parenthesis for example 2 4 6 Ports enclosed in brackets will include the devices currently attached to those ports The following examples illustrate several ways to specify the po...

Page 584: ... 33 44 55 66 77 aa and port WWN of the second device is 11 22 33 44 55 66 77 bb See also secPolicyAbort secPolicyActivate secPolicyCreate secPolicyDelete secPolicyDump secPolicyRemove secPolicySave secStatsShow switch admin secpolicyadd DCC_POLICY_abc 11 22 33 44 55 66 77 aa 11 22 33 44 55 66 77 bb 3 1 3 Member s have been added to DCC_POLICY_abc ...

Page 585: ...nagement method When security mode is first enabled using the command only the FCS_POLICY exists Before a policy is created there is no enforcement for that management method all access is granted After a policy has been created and a member has been added to the policy that policy becomes closed to all access except from included members If all members are then deleted from the policy all access ...

Page 586: ...e capitalized like regular policy names Valid values for DCC_POLICY_nnn are user defined alphanumeric or underscore characters The maximum length is 30 characters including the prefix DCC_POLICY_ member Specify a list of members for the security policy The members must be enclosed in quotation marks and separated by semicolons Depending on the policy type members can be specified using IP address ...

Page 587: ...parated by commas and enclosed in either brackets or parenthesis for example 2 4 6 Ports enclosed in brackets will include the devices currently attached to those ports The following examples illustrate several ways to specify the port values 1 6 Selects ports 1 through 6 Selects all ports on the switch 3 9 Selects ports 3 and 9 and all devices attached to those ports 1 3 5 Selects ports 1 through...

Page 588: ...t policy to allow anyone on the 192 168 5 0 24 network to access the fabric through sectelnet See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyDelete secPolicyDump secPolicyRemove secPolicySave secStatsShow switch admin secpolicycreate FRONTPANEL_POLICY 3 4 FRONTPANEL_POLICY has been created switch admin secpolicycreate DCC_POLICY_aB_7 11 22 33 44 55 66 77 aa 11 22 33 44 55 66 77 bb...

Page 589: ... of members of a policy acts as an access control list for that management method When security mode is first enabled using the command only the FCS_POLICY exists Before a policy is created there is no enforcement for that management method all access is granted After a policy has been created and a member has been added to the policy that policy becomes closed to all access except from included m...

Page 590: ...marks Valid security policy names are DCC_POLICY_nnn TELNET_POLICY HTTP_POLICY API_POLICY RSNMP_POLICY WSNMP_POLICY SES_POLICY HP does not support SES_POLICY MS_POLICY SERIAL_POLICY FRONTPANEL_POLICY SCC_POLICY OPTIONS_POLICY The specified policy name must be capitalized The DCC_POLICY_nnn name has the common prefix DCC_POLICY_ followed by a string of user defined characters These characters do no...

Page 591: ...Fabric OS 5 x command reference guide 591 secPolicyRemove secPolicySave secStatsShow ...

Page 592: ...or active database is Active the name for saved defined database is Defined If not specified all databases are displayed name Specify the name of a security policy you would like to display Valid values for this operand are DCC_POLICY_nnn FCS_POLICY TELNET_POLICY HTTP_POLICY API_POLICY RSNMP_POLICY WSNMP_POLICY SES_POLICY HP does not support SES_POLICY MS_POLICY SERIAL_POLICY FRONTPANEL_POLICY SCC...

Page 593: ..._________________________________ ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName __________________________________________________ 1 Yes 10 00 00 60 69 30 15 5c 1 primaryfcs HTTP_POLICY IpAddr __________________________________________________ 192 155 52 0 192 155 53 1 192 155 54 2 192 155 55 3 ____________________________________________________ primaryfcs admin secpolicydump TELNET_POL...

Page 594: ...594 Fabric OS commands See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyRemove secPolicySave secStatsShow ...

Page 595: ... are specified the command becomes interactive prompting you to supply valid values for the operands NOTE This command can be issued only from secure mode and only from the primary FCS switch If a backup FCS is moved to the first position it becomes the primary FCS after activation Operands This command has the following operands If no operand is specified the command becomes interactive and you a...

Page 596: ...69 10 02 18 1 switch5 2 No 10 00 00 60 69 00 00 5a 2 switch60 3 No 10 00 00 60 69 00 00 13 3 switch73 Please enter position you d like to move from 1 3 1 2 Please enter position you d like to move to 1 3 1 3 ____________________________________________________ DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName __________________________________________________ 1 Yes 10 00 00 60 69 10 02 18 1...

Page 597: ...from secure mode and only from the primary FCS switch Operands This command has the following operands secPolicyRemove name Specify the name of an existing policy you want to remove members from Valid values for this operand are DCC_POLICY_nnn FCS_POLICY TELNET_POLICY HTTP_POLICY API_POLICY RSNMP_POLICY WSNMP_POLICY SES_POLICY HP does not support SES_POLICY MS_POLICY SERIAL_POLICY FRONTPANEL_POLIC...

Page 598: ...gs domains or switch names If domain or switch names are used the switches associated must be present in the fabric or the command fails DCC_POLICY members The DCC_Policy_nnn is a list of devices associated with a specific switch and port combination The device is specified with a WWN string The switch and port combination must be specified in the following format switch port switch can be specifi...

Page 599: ... 40 from MS policy See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPolicySave secStatsShow OPTIONS_POLICY members NoNodeWWNZoning is the only option switch admin secpolicyremove MS_POLICY 12 24 45 10 0a 67 00 40 Member s have been removed from MS_POLICY ...

Page 600: ...ory of all switches in the fabric NOTE This command can be issued only from secure mode and only from the primary FCS switch Operands none Examples To save new policy set in all switches in the fabric See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPolicyRemove secStatsShow secPolicySave switch admin secpolicysave secpolicysave command was co...

Page 601: ...licy database without page breaks NOTE This command can be executed on any FCS switch in fabric Operands This command has the following operands secPolicyShow listtype Specify which database to display The name for active database is Active the name for saved defined database is Defined This operand must be enclosed in quotation marks If not specified all databases are displayed This operand is op...

Page 602: ... active ____________________________________________________ ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName __________________________________________________ 1 Yes 10 00 00 60 69 30 15 5c 1 primaryfcs HTTP_POLICY IpAddr __________________________________________________ 192 155 52 0 ____________________________________________________ switch admin secpolicyshow defined __________________...

Page 603: ...sis secstatsreset name list Availability admin Description Use this command to reset one or all security statistics to 0 This command can be issued to any switch If issued on the primary FCS switch this command can reset security statistics for any or all switches in the fabric secStatsReset ...

Page 604: ... INVALID_CERT SLAP FAIL SLAP_BAD_PKT TS_OUT_SYNC NO_FCS INCOMP_DB ILLEGAL_CMD The specified policy name must be all capitalized To access DCC policies enter DCC_POLICY Violations are not tracked for individual DCC policies The statistics for all DCC_POLICY violations are grouped together This operand is optional and the default is all statistics If the list operand is specified this operand is req...

Page 605: ...switch To reset DCC_POLICY statistics on domains 1 and 69 See also secFabricShow secStatsShow switch admin secstatsreset About to reset all security counters Are you sure yes y no n no y Security statistics reset to zero switch admin secstatsreset DCC_POLICY 1 69 Reset DCC_POLICY statistic ...

Page 606: ...to display one or all security statistics This command can be issued to any switch If issued on the primary FCS switch this command can retrieve and display the security statistics for any or all switches in the fabric NOTE This command displays security policy statistics in secure mode In nonsecure mode it only reports login statistics secStatsShow ...

Page 607: ...VALID_SIGN INVALID_CERT SLAP FAIL SLAP_BAD_PKT TS_OUT_SYNC NO_FCS INCOMP_DB ILLEGAL_CMD The specified policy name must be all capitalized To access DCC policies enter DCC_POLICY Violations are not tracked for individual DCC policies The statistics for all DCC_POLICY violations are grouped together This operand is optional and the default is all statistics If the list operand is specified then this...

Page 608: ...ET_POLICY for all switches in the fabric example from a nonsecure switch See also secFabricShow secStatsReset switch admin secstatsshow MS_POLICY Name Value MS 20 switch admin secstatsshow TELNET_POLICY Fabric Statistics Domain 1 Name Value TELNET_POLICY 0 Domain 69 Name Value TELNET_POLICY 0 Domain 70 Name Value TELNET_POLICY 0 ...

Page 609: ...every switch in the fabric Each switch has four accounts root factory admin and user Root and factory accounts are disabled for non FCS switches If they are temporarily activated by secTempPasswdSet those accounts are disabled by secTempPasswdReset or rebooting the switch NOTE This command can be issued only from secure mode and only from the primary FCS switch Operands This command has the follow...

Page 610: ...d of every account on domain 2 Temporary password of each account on domain 2 has been successfully reset if switch is non fcs switch it will further display Root and factory accounts on domain 2 have been disabled switch admin sectemppasswdreset All temporary passwords or account settings have been restored to fabric wide secure settings Passwords of permanent accounts have been reset to fabric w...

Page 611: ... FCS switch Each switch has four accounts root factory admin and user Root and factory accounts are disabled for non FCS switches This command can enable the root or factory account on a non FCS switch when you specify a password for those accounts The password should between 8 and 40 characters NOTE This command can be issued only from secure mode and only from the primary FCS switch Operands Thi...

Page 612: ...612 Fabric OS commands See also passwd secModeDisable secModeShow secNonFcsPasswd secTempPasswdReset ...

Page 613: ...ation problems This command aborts all current changes that have not been committed or activated NOTE This command can be issued from any switch in secure mode Operands none Examples To abort the current security transaction See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPolicyRemove secPolicySave secStatsShow secTransAbort switch admin sect...

Page 614: ...atch exactly they must contain the same FCS members and in the same order or the merge will fail 3 Reset the version stamp using the secVersionReset command on each secure fabric to be merged into the controller fabric The controller fabric does not require a version reset 4 Cascade the fabrics together When the secure fabrics merge the primary FCS switch in the controller fabric propagates its se...

Page 615: ...ples To view the sensor values See also fanShow tempShow sensorShow switch admin sensorshow sensor 1 Temperature is Ok value is 39 C sensor 2 Temperature is Absent sensor 3 Temperature is Absent sensor 4 Temperature is Absent sensor 5 Temperature is Ok value is 26 C sensor 6 Temperature is Ok value is 27 C sensor 7 Fan is Ok speed is 2537 RPM sensor 8 Fan is Ok speed is 2537 RPM sensor 9 Fan is Ok...

Page 616: ... module_name Specify the name of the module for which you want to view the debug and verbosity levels Module names are case sensitive This operand is optional if omitted this command displays the debug and verbose level for all modules level Specify the debug level for the specified module 0 to 9 A 0 value default specifies that no messages are to display Higher values cause more messages from tha...

Page 617: ...ehavior of the diagnostic test methods and post scripts The exact behavior varies but most commonly consists of disabling the ports defined when spinSilk or other functional tests are run for ESD or EMI testing purposes Operands This command has the following operands If no operand is specified the current value displays Examples To display the ESD mode See also spinSilk setEsdMode mode Specify 1 ...

Page 618: ... test methods so that ports without media installed are not tested Normally tests such as crossPortTest or spinSilk fail if any port is not operating properly but with media mode enabled the functional tests are skipped on ports that do not contain media Operands This command has the following operands Examples To enable disable and then display the media mode See also crossPortTest itemList miniC...

Page 619: ...iagnostic test methods so that ports without media installed are not tested Normally tests such as crossPortTest or spinSilk fail if any port is not operating properly but with media mode enabled the functional tests are skipped on ports that do not contain media Operands This command has the following operands Examples To enable disable and then display the media mode See also crossPortTest itemL...

Page 620: ... been disabled with this command If the CP is standby the modem is configured to answer an incoming call on the seventh ring unless modem dial in has been disabled In the recommended configuration a separate modem is connected to each modem port of CP0 and CP1 These modems connect to the telephone outlet through a RJ 11 Y adapter and standard telephone wire see Figure 1 During an incoming call bot...

Page 621: ...3 d 2 c 1 b 0 a POWER SUPPLY 1 3 POWER SUPPLY 2 4 Link 10 100 Mb s Active CP I O I O I RS 232 Link 10 100 Mb s Active CP I O I O I RS 232 15 d 14 c 13 b 12 a 11 d 10 c 9 b 8 a 7 d 6 c 5 b 4 a 3 d 2 c 1 b 0 a 15 d 14 c 13 b 12 a 11 d 10 c 9 b 8 a 7 d 6 c 5 b 4 a 3 d 2 c 1 b 0 a 15 d 14 c 13 b 12 a 11 d 10 c 9 b 8 a 7 d 6 c 5 b 4 a 3 d 2 c 1 b 0 a 15 d 14 c 13 b 12 a 11 d 10 c 9 b 8 a 7 d 6 c 5 b 4 ...

Page 622: ...edia installed are not tested Normally tests such as crossPortTest or spinSilk fail if any port is not operating properly but with media mode enabled the functional tests are skipped on ports that do not contain media Operands This command has the following operands Examples To enable disable and then display the media mode See also crossPortTest itemList miniCycle spinJitter spinSilk setSfpMode m...

Page 623: ...ween pairs of M M connected ports as follows P1 TX P1 RX P2 TX P2 RX P1 TX is a cable or internal loopback is a routing table entry The connections between pairs of M M ports are chosen to exercise the connections between as many chips or bloom quadrants as possible subject to the setting of allow_intra_chip and the availability of pairs of M M ports Any ports that are cross cabled are routed to e...

Page 624: ...the serial console By default no debug messages are displayed Operands This command has the following operands Examples To set the verbose level of a module named NS to value 3 See also dbgShow setVerbose module_name Specify the name of the module for which verbose level is to be set module names are case sensitive level Specify the verbose level 0 to 9 switch admin setverbose NS 3 switch admin db...

Page 625: ...l SFPs in the switch The summary displays the SFP type see switchShow for an explanation of the two letter codes and for serial ID SFPs the vendor name and SFP serial number Use this command with the slotnumber and portnumber operands to display detailed information about the serial ID SFP in that port Use the all operand to display detailed information for all available SFPs For Finisar smart SFP...

Page 626: ...ORP Serial No H112TUD Area 3 id sw Vendor FINISAR CORP Serial No H11QET9 Area 4 id sw Vendor IBM Serial No 21P53380BR0BE Area 5 id sw Vendor IBM Serial No 21P53380BS18A Area 6 id sw Vendor IBM Serial No 21P53380BS170 Area 7 id sw Vendor IBM Serial No 21P53380BS26B Area 8 Area 9 Area 10 Area 11 Area 12 Area 13 Area 14 Area 15 Area 16 id sw Vendor AGILENT Serial No 0105091301045274 output truncated ...

Page 627: ...0B Baud Rate 21 units 100 megabaud Length 9u 0 units 100 meters Length 50u 30 units 10 meters Length 62 5u 15 units 10 meters Length Cu 0 units 1 meter Vendor Name FINISAR CORP Vendor OUI 00 90 65 Vendor PN FTRJ 8519 7D 2 5 Vendor Rev Options 0012 Loss_of_Sig Tx_Disable BR Max 0 BR Min 0 Serial No H11QET9 Date Code 020429 Temperature 50 Centigrade Current 10634 mAmps Voltage 3164 8 mVolts RX Power...

Page 628: ...coding 1 8B10B Baud Rate 21 units 100 megabaud Length 9u 0 units km Length 9u 0 units 100 meters Length 50u 30 units 10 meters Length 62 5u 15 units 10 meters Length Cu 0 units 1 meter Vendor Name IBM Vendor OUI 08 00 5a Vendor PN IBM42P21SNY Vendor Rev AA10 Wavelength 0 units nm Options 001a Loss_of_Sig Tx_Fault Tx_Disable BR Max 5 BR Min 5 Serial No 21P7053164529 Date Code 01060501 output trunca...

Page 629: ... be executed from a session that is logged in from the console serial port This command cannot run from a telnet session This setting saves in the configuration database therefore persistent across reboots and power cycles On dual control processor CP systems a reboot on the standby CP is required for this command to take effect No action is required on the active CP Operands none Examples To disa...

Page 630: ...n This setting saves in the configuration database therefore persistent across reboots and power cycles On dual control processor CP systems a reboot on the standby CP is required for this command to take effect No action is required on the active CP CAUTION If flow control is enabled and if the console output is suspended for an extended period of time the switch might reboot HP recommends disabl...

Page 631: ...ade in contrast to the bladeDisable command which only disables external ports Unlike ports affected by bladeDisable ports on a slot disabled by this command are not re enabled after switchEnable switchStart or switchReboot Operands This command has the following operand Examples To power off blade unit 3 See also bladeDisable slotOn slotShow slotOff slotnumber Specify the slot number of the blade...

Page 632: ...his command to reenable a blade unit that was previously disabled Operands This command has the following operand Examples To power on blade unit 3 See also slotOff slotShow slotOn slotnumber Specify the slot number of the blade to enable This operand is required switch admin sloton 3 Slot 3 is being enabled ...

Page 633: ... must have a valid blade unit present and the blade unit must be of a type that can be powered off Operands This command has the following operand Examples To power off blade unit 3 See also powerOffListSet powerOffListShow slotPowerOn slotShow slotPowerOff slotnumber Specify the slot number of the blade to disable This operand is required switch admin slotpoweroff 3 Slot 3 is being powered off ...

Page 634: ...resent and the blade unit must be currently powered off The slotShow command reports such slots as being in the state of INSERTED NOT POWERED ON Operands This command has the following operand Examples To power on blade unit 3 See also slotOn slotPowerOff slotShow slotPowerOn slotnumber Specify the slot number of the blade to enable This operand is required switch admin slotpoweron 3 Powering on s...

Page 635: ...Blade not present or its type is not recognized ID Displays the hardware ID of the blade type Status Displays the status of the blade VACANT The slot is empty INSERTED NOT POWERED ON The blade is present in the slot but is turned off DIAG RUNNING POST1 The blade is present powered on and running the POST power on self test DIAG RUNNING POST2 The blade is present powered on and running the POST pow...

Page 636: ... slotPowerOff slotPowerOn switch admin slotshow Slot Blade Type ID Status 1 SW BLADE 2 FAULTY 2 SW BLADE 2 DISABLED 3 SW BLADE 2 ENABLED 4 SW BLADE 2 DIAG RUNNING POST2 5 CP BLADE 1 ENABLED User Ports Disabled 6 CP BLADE 1 ENABLED 7 UNKNOWN VACANT 8 SW BLADE 2 DIAG RUNNING POST1 9 SW BLADE 2 INSERTED NOT POWERED ON 10 UNKNOWN VACANT ...

Page 637: ...o repeatedly send predefined LPE 3 Verify the primitive is received at the same port 4 Check the receive port for possible code violation on nonframe data or BadOrdSet 5 Repeat step 2 through step 4 for all ports present until a The number of passcnt count requested is reached b All ports are marked bad Operands The optional operands are as follows slTest lb_mode mode Sets the loopback point for t...

Page 638: ...so cmemRetentionTest crossPortTest itemList portRegTest spinSilk duration count Specifies the duration in milliseconds to perform this test on the primitive The default value is 100 ports itemlist Specifies a list of blade ports to test By default all the blade ports in the specified slot slot is used See itemList for further details switch admin sltest ports 0 5 0 31 speed 4 lb_mode 1 passcnt 1 R...

Page 639: ...ity levels supported by the agent The first three communities are for read write rw access and the last three are for read only ro access The default value for the trap recipient of each community is 0 0 0 0 The length of community string should be in range of 2 to 16 characters The default values for the community strings are Community 1 Secret C0de Community 2 OrigEquipMfr Community 3 private Co...

Page 640: ...mpadmin3 User 4 snmpuser1 User 5 snmpuser2 User 6 snmpuser3 The user configuration is available in both the secure and nonsecure mode When the user selects the default option the user name and passwords are set to default In secure mode the above configuration has to be updated by the user on both primary and nonprimary switches individually Unlike community strings the user name and passwords are...

Page 641: ...e following FA MIB Specifying yes means the user can access FA MIB variables with an SNMP manager The default value is yes FICON MIB Specifying yes means the user can access FICON MIB variables with an SNMP manager The default value is yes HA MIB Specifying yes means the user can access Entity MIB and HA MIB variables with an SNMP manager The default value is yes SW TRAP Specifying yes means the S...

Page 642: ...then prompts you to change the values for each parameter default Sets the SNMP agent configuration data for a specified item to the default values Generally these default values might be available in the configuration database Factory default settings are set if the SNMP agent configuration parameters are not available in the configuration database snmpv1 Selects SNMPv1 related configuration param...

Page 643: ...ress in dot notation 10 32 225 2 Trap recipient Severity level 0 5 1 Community rw private Trap Recipient s IP address in dot notation 10 32 225 3 Trap recipient Severity level 0 5 2 Community ro public Trap Recipient s IP address in dot notation 10 32 225 4 Trap recipient Severity level 0 5 3 Community ro common Trap Recipient s IP address in dot notation 10 32 225 5 Trap recipient Severity level ...

Page 644: ...nmpuser1 Auth Protocol MD5 1 SHA 2 noAuth 3 3 3 3 Priv Protocol DES 1 noPriv 2 2 2 2 User ro snmpuser2 Auth Protocol MD5 1 SHA 2 noAuth 3 3 3 3 Priv Protocol DES 1 noPriv 2 2 2 2 User ro snmpuser3 Auth Protocol MD5 1 SHA 2 noAuth 3 3 3 3 Priv Protocol DES 1 noPriv 2 2 2 2 SNMPv3 trap recipient configuration Trap Recipient s IP address in dot notation 0 0 0 0 192 168 45 90 UserIndex 1 6 1 Trap reci...

Page 645: ...t subnet area in dot notation 0 0 0 0 10 33 0 0 Read Write true t false f true f Access host subnet area in dot notation 0 0 0 0 Read Write true t false f true Access host subnet area in dot notation 0 0 0 0 Read Write true t false f true Committing configuration done switch admin snmpconfig show mibCapability FE MIB YES SW MIB YES FA MIB YES FICON MIB YES HA MIB YES SW TRAP YES swFCPortScn YES sw...

Page 646: ...tocol SNMPv1 RFC1213 Management information Base for Network Management of TCP IP based internets MIB II RFC2574 User based Security Model USM for version 3 of the Simple Network Management Protocol SNMPv3 switch admin snmpconfig default systemGroup This command will reset the agent s system group configuration back to factory default sysDescr Fibre Channel Switch sysLocation End User Premise sysC...

Page 647: ...ccess FA MIB variables with an SNMP manager The default value is yes HA MIB Specifying yes means the user can access Entity MIB and HA MIB variables with an SNMP manager The default value is yes SW TRAP Specifying yes means the SNMP management application can receive SW TRAPS from the switch The default value is yes FA TRAP Specifying yes means the SNMP management application can receive FA TRAPS ...

Page 648: ...atchTrap FA TRAP connUnitStatusChange connUnitSensorStatusChange HA TRAP fruStatusChanged cpStatusChanged FA MIB yes y no n yes FICON MIB yes y no n yes n HA MIB yes y no n yes SW TRAP yes y no n yes swFCPortScn yes y no n yes swEventTrap yes y no n no swFabricWatchTrap yes y no n yes swTrackChangesTrap yes y no n no y FA TRAP yes y no n yes n SW EXTTRAP yes y no n no HA TRAP yes y no n yes fruSta...

Page 649: ... Entity MIB and HA MIB variables with an SNMP manager The default value is yes SW TRAP Specifying yes means the SNMP management application can receive SW TRAPS from the switch The default value is yes Users can also turn on or off individual SW Traps The individual SW traps are swFCPortScn swEventTrap swFabricWatchTrap and swTrackChangesTrap FA TRAP Specifying yes means the SNMP management applic...

Page 650: ...fgDefault agtCfgSet agtCfgShow snmpConfig switch admin snmpmibcapshow FE MIB YES SW MIB YES FA MIB YES FICON MIB NO HA MIB YES SW TRAP YES swFCPortScn YES swEventTrap NO swFabricWatchTrap YES swTrackChangesTrap YES FA TRAP NO SW EXTTRAP NO HA TRAP YES fruStatusChanged YES cpStatusChanged YES fruHistoryTrap NO ...

Page 651: ...are still circulating and that they are still in order In this manner the entire path to the remote switch might be verified as can be the proper in order delivery operation of any trunk groups present The switch remains in normal operation while this test is running however some performance degradation occurs due to the ISL links being saturated with test frames Because of this you should use cau...

Page 652: ... help pages for further details setfail mode Instruct spinFab how to mark failed ports If set to 1 it will mark failing ports as FAILED If set to 0 it will not mark failed ports as FAILED It is to minimize the impact on live fabrics This test normally logs errors but does not set the port status to FAILED This parameter is provided to force the failing ports to be marked as FAILED in the same mann...

Page 653: ...TATE_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest spinSilk sramRetentionTest ...

Page 654: ...es to send in millions The test progresses until the specified number of frames transmits on each port The default value is 10 which represents 10 million frames lb_mode mode Select the loopback point for the test By default spinJitter uses port loopback 0 1 2 3 5 Cable loopback Port loopback loopback plugs External SERDES loopback Silkscreen loopback Internal parallel loopback spd_mode mode Speci...

Page 655: ...run 3 5 4 6 Set all even ports speed for 2 Gb s Set all odd ports speed for 1 Gb s Set all even ports speed for 1 Gb s Set all odd ports speed for 2 Gb s ports itemlist Specifies a list of user ports to test By default all the user ports in the specified slot slot will be used See itemList for further details switch admin spinjitter ports 1 0 1 2 Running SpinJitter One moment please Ports Segmente...

Page 656: ...TRUNC ERR_STAT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT ERR_STAT_TRUNC FDET_PERR FINISH_MSG_ERR FTPRT_STATUS_ERR INIT LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWork...

Page 657: ...Fabric OS 5 x command reference guide 657 See also backport camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest ...

Page 658: ...use self loopback plugs as each port exchanges frames with up to 10 other predetermined ports Frames are exchanged with a selected port from the ASIC 0 0 0 1 0 2 0 3 and so forth mirrored on the port on the next ASIC 0 4 0 8 and so forth and mirrored on the port on the next blade where applicable 0 16 0 32 and so forth An error is reported if there are missing plugs If you want to use cables inste...

Page 659: ...he data used is as follows CSPAT 0x7e 0x7e 0x7e 0x7e BYTE_LFSR 0x69 0x01 0x02 0x05 RANDOM 0x25 0x7f 0x6e 0x9a RDRAM_PAT 0xff 0x00 0xff 0x00 Because this test includes the media and the fiber cable in its test path its results combined with the results of portLoopbackTest can be used to determine which components of the switch are faulty Operands This command has the following operands nmegs count ...

Page 660: ...6 Set all even ports speed to auto negotiate set all odd ports speed to 1 Gb sec Set all even ports speed to auto negotiate set all odd ports speed to 2 Gb sec Set all odd ports speed to auto negotiate set all even ports speed to 1 Gb sec Set all odd ports speed to auto negotiate set all even ports speed to 2 Gb sec For lb_mode set to 2 3 the following speed modes are available to test FIFO underr...

Page 661: ...2LONG ERR_STAT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT switch admin spinsilk ports 1 0 1 2 Running Spin Silk One moment please Ports Segmented 0 switchName switch switchType 10 1 switchState Offline switchRole Disabled switchDomain 1 unconfirmed switchId fffc01 switchWwn 10 00 00 60 69 80 03 0c switchBeacon OFF blade1 Beacon OFF blade2 Beacon OFF blade3 Be...

Page 662: ...BLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also backport camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest portRegTest spinJitter sramRetentionTest ...

Page 663: ...RetentionTest command cannot be executed on an operational switch You must first disable the switch using the switchDisable command Operands This command has the following operands Examples To run a data retention test sramRetentionTest slot slotnumber Specify the number of the slot on which the diagnostic operates The ports specified are relative to this slot number The default is set to 0 and de...

Page 664: ...s if failures are detected BUS_TIMEOUT REGERR REGERR_UNRST See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also camTest centralMemoryTest cmiTest crossPortTest dataTypeShow itemList portLoopbackTest spinSilk ...

Page 665: ... statsClear slot slotnumber Specifies the slot on which to operate If this option is not specified the default slot is assumed The default slot is 0 and designed to operate on fixed port count products if use_bports is set to a nonzero value uports itemlist Specifies the list of user ports to clear bports itemlist Specifies the list of blade ports to clear use_bports value If value is nonzero the ...

Page 666: ...re are 16 of these statistics counters 0 15 The number of frames with CRC error that matched the corresponding ALI 0 127 respectively This command cannot be executed on an operational switch You must first disable the switch using the switchDisable command NOTE There is a link table that stores 16 pairs of SID DID address Each of the SID DID pairs is named a link This table is used for gathering s...

Page 667: ...orts one or more of the following error messages DIAG STSINIT DIAG STSNULL DIAG STSSID DIAG STSXMIT DIAG STSRCV DIAG STSFRMCNT DIAG STSWRDCNT DIAG STSALPACNT See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also camTest itemList ...

Page 668: ...est is running in nonsingle mode use stopporttest to stop the test Operands The command has the following operands Examples To stop the portTest command See also crossPortTest fportTest loopPortTest portLoopbackTest portTest portTestShow spinFab stopPortTest ports itemlist Specify a list of user ports to test By default all the user ports in the switch are tested See itemList help pages for furthe...

Page 669: ... FTP parameters s has the following optional operands h hostip u username p password d remotedirectory Specifies the FTP host IP address It must be an IP address hostip should be less than 48 characters Specifies the FTP user name username should be less than 48 characters Specifies the FTP user password If the user name is anonymous the password is not needed password should be less than 48 chara...

Page 670: ...ime interval at which to check the FTP server See also supportSave supportShow traceDump traceFtp traceTrig switch admin supportftp s h 192 168 67 126 u anonymous d tracedump supportftp ftp parameters changed switch admin supportftp t 24 supportftp ftp check period changed ...

Page 671: ...chassisname slot YYYYMMDDHHMM tracedump dmp supportShow chassisname slot YYYYMMDDHHMM supportShow Zone log chassisname slot YYYYMMDDHHMM zone ss RCS command log chassisname slot YYYYMMDDHHMM rcscmd ss NS event log chassisname slot YYYYMMDDHHMM ns ss n Does not prompt you for confirmation This operand is optional if omitted you are prompted for confirmation c Uses the FTP parameters saved by the co...

Page 672: ...es switch S5 200405200014 supportShow ss 1 11 MB 346 39 kB s switch admin supportsave This command will collect RASLOG TRACE supportShow and other support information and then transfer them to a FTP server Only the local CP s information will be saved and supportShow information is only available on the Active CP This operation can take several minutes OK to proceed yes y no n no y Host IP 192 168...

Page 673: ...Fabric OS 5 x command reference guide 673 supportShow traceDump traceFtp traceTrig ...

Page 674: ...e groups listed next is not the same as executed by the command See supportShow reference on page 789 for more information The commands can be arranged in groups as follows OS ENABLED by default Linux commands are not documented in this manual mii tool du ps rpm dmesg fstab mtab various proc entries find core files exception ENABLED by default errDump pdShow port ENABLED by default diagShow per sl...

Page 675: ...dmiShow nsShow nsAllShow nscamShow security ENABLED by default authUtil secFabricShow secGlobalShow secModeShow secStatsShow network ENABLED by default bootenv df ifconfig route hostname portlog ENABLED by default portLogDump system ENABLED by default myId version firmwareShow upTime switchStatusShow switchShow haDump includes haShow and ipAddrShow tempShow sensorShow psShow licenseShow portFlagsS...

Page 676: ...port perfmon DISABLED by default ps_dump per port this group has lengthy output ficon DISABLED by default this group has lengthy output ficoncupshow fmsmode ficoncupshow modereg ficonDbg dump rnid ficonDbg log ficonShow ilir ficonShow lirr ficonShow rlir ficonShow rnid ficonShow switchrnid ficucmd dump A Operands This command has the following operands slotnumber portnumber1 portnumber2 Specify th...

Page 677: ... 3 25 1 user load average 1 55 1 20 1 11 switchshow switchName Ulysses2 switchType 10 1 switchState Online switchMode Native switchRole Principal switchDomain 1 switchId fffc01 switchWwn 10 00 00 60 69 80 03 0c zoning OFF switchBeacon OFF blade1 Beacon OFF blade2 Beacon OFF blade4 Beacon OFF Area Slot Port Media Speed State 0 1 0 id N2 Online Loopback Slot 1 Port 0 1 1 1 id N2 Online Loopback Slot...

Page 678: ...678 Fabric OS commands See also supportFtp supportSave supportShowCfgDisable supportShowCfgEnable supportShowCfgShow traceDump traceFtp traceTrig ...

Page 679: ...commands under the supportShow command See also supportShow supportShowCfgEnable supportShowCfgShow supportShowCfgDisable os Disables the OS group commands exception Disables the exception group commands port Disables the port group commands fabric Disables the fabric group commands services Disables the service group commands security Disables the security group commands network Disables the netw...

Page 680: ...ds under the supportShow command See also supportShow supportShowCfgDisable supportShowCfgShow supportShowCfgEnable os Enables the OS group commands exception Enables the exception group commands port Enables the port group commands fabric Enables the fabric group commands services Enables the service group commands security Enables the security group commands network Enables the network group com...

Page 681: ...wCfgDisable commands to modify which groups are displayed See supportShow reference on page 789 for more information Operands none Examples To display which groups of commands are enabled in the supportShow command See also supportShow supportShowCfgDisable supportShowCfgEnable supportShowCfgShow switch admin supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enab...

Page 682: ...ED pattern associated with an active faulty or disabled port is suppressed and the beaconing pattern is shown However if diagnostic frame based tests portLoopbackTest crossPortTest and spinSilk are executed two patterns are interleaved The diagnostic test flickers the LEDs green and simultaneously the beaconing mode runs the LEDs amber Use the switchShow command to display the status of beaconing ...

Page 683: ...e process can be observed and verified by watching the front panel LEDs change to slow flashing yellow as each port is disabled A persistently disabled switch can be temporarily enabled using the switchEnable command A temporarily enabled switch remains disabled after a reboot NOTE Performance Monitoring cannot be added to any port on a persistently disabled switch Operands none Examples To disabl...

Page 684: ...ins the principal switch at the end of the count down then it assigns itself a domain ID If another switch assumes the principal role then this switch becomes a subordinate switch and accepts a domain ID from the principal See FC SW for a complete description of this process The enable process can be observed and verified by watching the front panel LEDs change from slow flashing yellow as each po...

Page 685: ... appears for that port The output of portShow displays the achieved speed level and portCfgShow displays the user s desired speed setting Operands This command has the following required operand Examples To set the speed level for all ports on a switch See also portCfgSpeed portShow switchCfgSpeed speed_level Specify the speed of a port Valid values are one of the following 0 1 2 4 Auto sensing mo...

Page 686: ...ate the trunking configuration the ports for which the configuration applies are disabled and reenabled with the new trunk configuration As a result the traffic through these ports might be disrupted for a short period of time Operands This command has the following operand Examples To disable trunking on a switch See also portCfgShow portCfgTrunkPort portShow switchShow switchCfgTrunk mode Specif...

Page 687: ...ion changes using configure or configDefault or before running many of the diagnostic tests All commands that require the switch to be disabled send an error if invoked while the switch is enabled The switch does not need to be disabled before rebooting or powering off As each port is disabled the front panel LED changes to a slow flashing yellow Operands none Examples To disable the switch See al...

Page 688: ... countdown is displayed If this switch remains the principal switch at the end of the countdown then it assigns itself a domain ID If another switch assumes the principal role then this switch becomes a subordinate switch and accepts a domain ID from the principal See FC SW for a complete description of this process As each port is enabled the front panel LED changes to green for online ports blac...

Page 689: ...mmand with no operand to display the current switch name Changing the switch name causes a domain address format RSCN to be issued see FC FLA for a description of RSCNs The switch name also can be changed using HP Advanced Web Tools Operands This command has the following optional operand Examples To change a switch name to antina note the change in the prompt text See also chassisShow switchShow ...

Page 690: ...ported on single domain systems Operands none Examples To reboot an operational switch See also switchShutdown switchStart switchReboot switch admin switchreboot Stopping all switch daemons Done Powering off slot 1 Done Powering off slot 4 Done Checking all slots are powered off Done Cleaning up kernel modules Done Initializing kernel modules Done Starting all switch daemons Done Powering on slot ...

Page 691: ... disabled switchDomain Displays the switch domain ID 0 to 31 or 1 to 239 switchId Displays the switch embedded port D_ID switchWwn Displays the switch world wide name WWN switchBeacon Displays the switch beaconing state on or off bladeBeacon Displays the blade beaconing state on or off Area Part of the 24 bit port ID which consists of domain area number and optional AL_PA Slot Slot number slots nu...

Page 692: ...WN and name of attached switch Point to point port displays WWN of attached N_Port Point to point but not yet E_Port or F_Port Loop port displays number of NL_Ports Port is the master port in a group of trunking ports Trunk port master is port x Port is configured as a trunking port the master port is port number x E_Port is an upstream path towards the principal switch of the fabric E_Port is a d...

Page 693: ...bordinate switchDomain 2 switchId fffc02 switchWwn 10 00 00 60 69 00 02 48 switchBeacon OFF blade1 Beacon OFF blade4 Beacon OFF Area Slot Port Media Speed State 0 1 0 id N2 Online E Port 10 00 00 60 69 00 02 1c san130 1 1 1 id N2 Online E Port 10 00 00 60 69 00 02 1c san130 2 1 2 id N2 Online E Port 10 00 00 60 69 00 02 1c san130 3 1 3 id N2 Online E Port 10 00 00 60 69 00 02 1c san130 4 1 4 id N2...

Page 694: ... all the daemons associated with the switch frees the resources and object states associated with the switch to a clear state and disables all the ports and blades associated with the switch NOTE This command is not supported on single domain systems Operands none Examples To halt the operational switch See also switchReboot switchStart switchShutdown switch admin switchshutdown Stopping all switc...

Page 695: ...ated with the switch initializes the object states associated with the switch to a clear state and enables all the ports and blades associated with the switch NOTE This command is not supported on single domain systems Operands none Examples To initialize the current switch See also switchReboot switchShutdown switchStart switch admin switchstart Initializing kernel modules Done Starting all switc...

Page 696: ...e current parameters in a three column table format shown in Table 18 The command then prompts the user to change the values for each policy parameter The default values for the policy parameters are in shown Table 18 Any single contributor can force the overall status of the switch to MARGINAL or DOWN For example assuming that the switch contributor values are set to the default values if there i...

Page 697: ...eratures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 Note that the value 0 for a parameter means that it is NOT used in the calculation In addition if the range of settable values in the prompt is 0 0 the policy parameter is NOT applicable to the switch Simply hit the Return key Out of range Flash contributing to MARGINAL status 0 1 1 MarginalP...

Page 698: ...d column indicates the minimum number that contributes to the DOWN status and the third column indicates the minimum number that contributes to the MARGINAL status The parameters can be set by the switchStatusPolicySet command The existence of policies such as Fans PowerSupplies CP WWN and Blade might differ from platform to platform For example if the FaultyPorts DOWN parameter is set to 3 and th...

Page 699: ...es See also switchStatusPolicySet switchStatusShow switch admin switchstatuspolicyshow The current overall switch status policy parameters Down Marginal PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 ...

Page 700: ...the following contributors Power supplies Temperatures Fans WWN servers dual CP systems only Standby CP dual CP systems only with HA enabled Blades bladed systems only Flash Marginal ports Faulty ports Missing SFPs Status values are HEALTHY MARGINAL or DOWN depending on whether thresholds established by switchStatusPolicySet have been exceeded The overall status is based on the most severe status ...

Page 701: ...ime 06 19 2003 10 48 31 AM Switch Name switch IP address 10 10 255 255 SwitchState MARGINAL Duration 00 06 Power supplies monitor HEALTHY Temperatures monitor HEALTHY Fans monitor MARGINAL WWN servers monitor HEALTHY Standby CP monitor HEALTHY Blades monitor HEALTHY Flash monitor HEALTHY Marginal ports monitor HEALTHY Faulty ports monitor HEALTHY Missing SFPs monitor HEALTHY All ports are healthy ...

Page 702: ...Availability all users Description Use this command to display the current time and the amount of time that the switch has been operational Operands none Examples To view the uptime for the switch See also switchReboot switchShutdown switchStart switchUptime switch user switchuptime 9 50pm up for 20 mins ...

Page 703: ... the appropriate log files or users depending on the system configuration The specified facility is used when forwarding messages to the servers added through the command syslogdIpAdd The default facility is LOG_LOCAL7 Operands This command has following operand Examples To set the syslog facility to LOG_LOCAL1 See also syslogdIpAdd syslogdIpRemove syslogdIpShow syslogdFacility l level Specifies t...

Page 704: ...te log files or users depending on the system configuration When one or more IP addresses are configured the switch forwards all error log entries to the syslogd on the specified servers Up to six servers are supported Operands This command has the following required operand Examples To add the address 192 168 1 60 to the list of machines to which system messages are sent See also errModuleShow sy...

Page 705: ... the server that is running the syslogd process Operands This command has the following operand Examples To remove the address 192 168 1 60 from the list of machines to which system messages are sent See also errModuleShow syslogdIpAdd syslogdIpShow syslogdIpRemove ip_address Specify the IP address of the server running syslogd This operand is required switch admin syslogdipremove 192 168 1 60 ...

Page 706: ... this command to display all syslog daemon IP addresses in the configuration database Operands none Examples To display all syslog daemon IP addresses See also errModuleShow syslogdIpAdd syslogdIpShow switch admin syslogdipshow syslog IP address 1 192 168 1 60 syslog IP address 2 192 168 1 88 syslog IP address 3 192 168 2 77 ...

Page 707: ...nd output displays The burn in tests are designed to operate with switches connected to a fabric and restrict the frame loopback to inside the unit If loopback plugs are installed in all ports the burn in parameter min_lb_mode can be changed to 1 to test the Fibre Channel through the loopback plug Operands This command has the following operands systemVerification parameters Invokes the diagSetCyc...

Page 708: ... the FRU to be tested switch admin systemverification short systemverification Setting parameters for short run systemverification burnin parameters CURRENT KEYWORD DEFAULT 1 number_of_runs 1 2 vib 2 10 thermal 10 SYSTEMVERIFICATION label BURNIN 2 min_lb_mode 2 1 tbr_passes 1 1 prt_on 1 1 cntmem_on 1 1 cmi_on 1 1 retention_on 1 1 cam_on 1 1 flt_passes 50 1 sta_passes 25 1 plb_nframes 100 1 txd_nfr...

Page 709: ...Fabric OS 5 x command reference guide 709 See also burninErrClear burninStatus diagSetBurnin diagSetCycle ...

Page 710: ... applicable the sensor state and the temperature The temperature readings are given in both Centigrade and Fahrenheit See the hardware reference manual for your switch to determine the normal temperature range Operands none Examples To display temperature and status sensors See also fanShow psShow sensorShow slotShow tempShow switch user tempshow Index Slot State Centigrade Fahrenheit 1 1 Ok 41 10...

Page 711: ...erand to set the login timeout value to the specified interval A value of 0 disables timeout functionality of login sessions Operands This command has the following operand Examples To set the idle timeout to 10 minutes See also none timeout timeval Specify the number of minutes for the Telnet timeout value Valid values are 1 to 99 999 or 0 to disable login timeouts This operand is optional if omi...

Page 712: ... reaching destination domain Name The name of the destination switch Path Count The number of currently active paths to the destination domain Hops The maximum number of hops to reach destination domain Out Port Port to which incoming frame are forwarded to reach the destination domain In Ports Input ports that use the corresponding out port to reach the destination domain This is the same informa...

Page 713: ...ain ID 1 Domain 6 Metric 500 Name switch Path Count 4 Hops 1 Out Port 60 In Ports None Total Bandwidth 2 Gbps Bandwidth Demand 0 Flags D Hops 1 Out Port 61 In Ports None Total Bandwidth 2 Gbps Bandwidth Demand 0 Flags D Hops 1 Out Port 62 In Ports None Total Bandwidth 2 Gbps Bandwidth Demand 0 Flags D Hops 1 Out Port 58 In Ports None Total Bandwidth 2 Gbps Bandwidth Demand 0 Flags D ...

Page 714: ... number 0 on nonbladed systems and YYYYMMDDHHMMSS year month day hour minute second is the trace dump time Operands This command has the following mutually exclusive operands This command has the following optional operand Examples To initiate a background trace dump from slot 5 To remove a trace dump See also supportFtp supportSave supportShow traceDump S Displays dump status n Initiates a backgr...

Page 715: ...Fabric OS 5 x command reference guide 715 traceFtp traceTrig ...

Page 716: ...iately NOTE If there is no parameter specified this command defaults to traceFtp S Default remote file name format for traceFtp n is switchname S YYYYMMDDHHMMSS dmp where is the slot number 0 if it is on nonbladed system and YYYYMMDDHHMMSS is trace dump time year month day hour minute second Operands This command has the following mutually exclusive operands traceFtp S Displays the trace auto FTP ...

Page 717: ...rs Specifies the FTP user name username should be less than 48 characters Specifies the FTP user password If the user name is anonymous the password is not needed password should be less than 48 characters Specifies the remote directory in which to store a trace dump file traceFtp cannot take a slash as a directory name remotedirectory should be less than 48 characters Specifies the remote file in...

Page 718: ... a and r options also have the following required operand Examples To set a trace trigger To remove a trace trigger traceTrig S Displays trace triggers for the specified slot a Sets a trace trigger for the specified slot r Removes a trace trigger from the specified slot R Removes all trace triggers from the specified slot s slot Specifies the slot number from which a trace dump is generated If thi...

Page 719: ...Fabric OS 5 x command reference guide 719 To remove all trace triggers See also supportFtp supportSave supportShow traceFtp traceFtp switch admin tracetrig R all trace triggers are removed ...

Page 720: ...e this command to display information about the track changes commands Examples To display information on the track changes feature commands See also trackChangesSet trackChangesShow trackChangesHelp switch admin trackchangeshelp trackChangesSet Configure alert for login logout config update trackChangesShow Displays status of track changes ...

Page 721: ...how command to view the error log Operands This command has the following operands Examples To enable the track changes feature trackChangesSet mode Specify 1 to enable the track changes feature or specify 0 to disable the feature The default if no operand is specified is to disable the track changes feature This operand is optional snmptrapmode Specify 1 to enable errors to be sent to the SNMP TR...

Page 722: ...722 Fabric OS commands See also agtCfgSet agtCfgShow trackChangesHelp trackChangesShow ...

Page 723: ... is turned on or off and if SNMP traps are generated The output from the track changes feature is dumped to the error log for the switch Use the errDump command or the errModuleShow command to view the error log Operands none Examples To display the status of the track changes feature See also trackChangesHelp trackChangesSet trackChangesShow switch admin trackchangesshow Track changes status ON T...

Page 724: ... port port_id connect to different switches port port_id is not a trunking port due to E_Port being disabled or trunking might be disabled at remote port port port_id and port port_id cannot trunk please check link length to make sure difference is less than 400m Operands This command has the following operands Examples To debug a trunk connection trunkDebug port1 Specify the area number of port 1...

Page 725: ...Fabric OS 5 x command reference guide 725 See also portCfgTrunkPort switchCfgTrunk trunkShow ...

Page 726: ...ections WWN Displays the WWN of the connected port deskew The time difference for traffic to travel over each ISL compared to the time to the shortest ISL in the group The number corresponds to nanoseconds divided by 10 The firmware automatically sets the minimum deskew value of the shortest ISL to 15 Master Displays whether this trunking port connection is the master port connection for the trunk...

Page 727: ...fy the ipaddr operand to set the clock server IP address and enable fabric wide clock synchronization with the specified clock server The NTP server used must support a full NTP client Fabric OS 3 1 0 and 2 6 1 have an SNTP client and hence will accept an SNTP or NTP server but v4 1 0 has an NTP client so for the proper functioning of a mixed fabric with external time synchronization it is necessa...

Page 728: ...set the value to an NTP server at the specified IP address and then verify that the new IP address was saved See also date switch admin tsclockserver LOCL switch admin tsclockserver 123 123 123 123 Updating Clock Server configuration done switch admin tsclockserver 123 123 123 123 ...

Page 729: ...eration in any way System services started during the switch bootup reflect a time zone change only at the next reboot Enter this command with no parameters to display the time zone setup With the valid parameters it sets the time zone for an individual switch Negative houroffset values mean the local time is behind GMT for example 8 0 is GMT 08 00 Positive houroffset values mean the local time is...

Page 730: ...GMT 3 30 See also date switch admin tsTimeZone Time Zone Hour Offset 0 Time Zone Minute Offset 0 switch admin tsTimeZone 3 30 Updating Time Zone configuration done System Time Zone change will take effect at next reboot switch admin tsTimeZone Time Zone Hour Offset 3 Time Zone Minute Offset 30 ...

Page 731: ...ddress read 0000 FFFF pattern and write FFFF 0000 Subtest 3 turbo ram r m w inc 2 4 For each decrementing address read FFFF 0000 pattern and write 0000 FFFF Subtest 4 turbo ram r m w dec 1 5 For each decrementing address read 0000 FFFF pattern and write FFFF 0000 Subtest 5 turbo ram r m w dec 2 6 Repeat Steps 1 5 with AAAA 5555 pattern Operands This command has the following operands Examples To e...

Page 732: ... more of the following error messages DIAG WTEST DIAG INC_RWTEST DIAG DEC_RWTEST DIAG RAMINIT_TO See the HP StorageWorks Fabric OS 5 x diagnostics and system error messages reference guide for more information See also centralMemoryTest cmemRetentionTest cmiTest portRegTest sramRetentionTest ...

Page 733: ...ll ports present for parallel loopback Then for each pair of source quadrants and destination ports 2 Set up a source port to route frames to a destination port and a destination port to route frames to the CPU 3 Transmit frame F through the source port 4 Pick up the frame from the destination port 5 Check if any of the eight statistic error counters are not 0 ENC_in CRC_err TruncFrm FrmTooLong Ba...

Page 734: ... The exact operation of modes 5 through 8 depends on the loopback mode selected When speed modes 5 through 8 are used with cables they must be connected EVEN ODD or the test fails 0 1 2 3 4 Run test at 1 Gb s 2 Gb s and 4 Gb s Run test at 1 Gb s Run test at 2 Gb s Bloom default Set all even ports speed for autonegotiate Set all odd ports speed for 1 Gb s In test at 4 Gb s Condor default For lb_mod...

Page 735: ...est centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest nonstop mode Specify nonstop mode If set to a nonzero value the test does not stop on the first error The default value is 0 ports itemlist Specify a list of user ports to test By default all of the user ports in the current switch are tested This option might be used to r...

Page 736: ...rrently logged on and the system load averages for the past 1 5 and 15 minutes For up and powered on times less than 60 seconds the time is displayed in seconds For times greater than or equal to 60 seconds the time is displayed in minutes The output format adjusts accordingly Operands none Examples To display the length of time the system has been operational See also date fastBoot reboot upTime ...

Page 737: ...nd However the static route is remembered so that it can be enforced if this port becomes the port of a valid path in the future If a static route requires some hardware resources that are already used a platform conflict warning message is displayed and the configuration does not take effect The in_area port can be either an F_Port or an E_Port NOTE When using static routes load sharing might be ...

Page 738: ...ng in from port 1 and addressed to domain 2 to go through port 5 See also configShow interfaceShow uRouteRemove uRouteShow switch admin urouteconfig 1 2 5 done switch admin urouteshow 1 1 2 Local Domain ID 1 In Port Domain Out Port Metric Hops Flags Next Dom Port 1 2 5 500 1 S 2 5 ...

Page 739: ...load sharing DLS is set If DLS is not set the route remains as is with its route attribute changed from static to dynamic Operands This command has the following operands Examples To remove a static route for all traffic coming in from port 1 and addressed to domain 2 See also dlsShow configShow uRouteConfig uRouteShow uRouteRemove in_area Specify the F_Port or E_Port input port of the static rout...

Page 740: ...guide for more information regarding the extended edge PID format Domain Destination domain of incoming frame Out Port Port to which the incoming frame is to be forwarded Except for the cases in which you perform a port swap or enable extended edge PID PID Format 2 on a switch the value is equal to the Area field displayed by the switchShow command For port swap operations the value is equal to th...

Page 741: ...g information for all input ports in the switch domainnumber Displays routing information for the specified domain This operand is optional if omitted the routing information for all domains in the fabric is displayed switch admin urouteshow Local Domain ID 3 In Port Domain Out Port Metric Hops Flags Next Dom Port 0 1 11 1000 1 D 1 0 11 2 0 1500 2 D 4 0 4 0 500 1 D 4 0 16 1 27 1000 1 D 1 1 27 2 16...

Page 742: ... switch distributes the update to the entire fabric As a result all switches supporting customer defined accounts will have the same account database All accounts that not consistent with the primary FCS switch will be deleted and saved in the backup database Administrators can use the recover action to restore the accounts Operands Without any specified action the command prints out the usage The...

Page 743: ...ves a text description for the new account This command also prompts for an initial password The following rules apply to add a new account 1 username must be unique and is case sensitive 2 username must begin with a letter and contain only letters numbers and underscore 3 The maximum length of username is 40 characters 4 description is optional The maximum length is 40 printable ASCII characters ...

Page 744: ...ou cannot change the rolename or description for accounts at the same or higher authorization level 3 An account cannot change the rolename of itself 4 Except for the default root account no account can disable itself recover Recover all accounts from backup database The backup database is created in Secure Fabric OS when certain operations cause a switch to delete some of its customer created acc...

Page 745: ...ount login name If old_username is a default login name new_username cannot be another default login name If new_username is a default login name it must indicate the same role as old_username When using HP Secure Fabric OS rename the admin level login name to the HP specific default of admin and the user level login name to the HP specific default of user before enabling security otherwise the sw...

Page 746: ...next reboot the dates can differ Operands none Examples To display the firmware version information in a switch See also firmwareDownload reboot version Kernel Displays the version of switch kernel operating system Fabric OS Displays the version of switch Fabric OS Made on Displays the build date of firmware running in switch Flash Displays the build date of firmware stored in flash proms BootProm...

Page 747: ...his command displays the following fields Operands none voltShow FRU Type One of the following values CHASSIS FAN I2C Control CFlash SW BLADE switch CP BLADE control processor or UNKNOWN Number Slot or unit number if applicable Voltage levels The measured voltage for these designated voltage levels 1 2 or 1 8 volts depending on the ASIC type 2 5 volts 3 3 volts 5 volts 12 volts 48 volts and 53 vol...

Page 748: ...3V SW BLADE Slot 2 1 82 2 51 3 30 11 94 SW BLADE Slot 3 0 00 0 00 0 09 12 31 CP BLADE Slot 5 2 48 3 29 5 17 12 50 CP BLADE Slot 6 2 50 3 29 5 17 12 50 SW BLADE Slot 8 1 80 2 52 3 30 12 00 SW BLADE Slot 9 1 80 2 51 3 97 11 94 SW BLADE Slot 10 1 82 2 52 3 29 11 94 FAN Unit 1 47 49 52 50 FAN Unit 2 47 49 52 23 FAN Unit 3 45 50 52 23 Sensor Status above max below min ...

Page 749: ...ll switches have a numeric address that is the unique Fibre Channel address used for communicating with the switch The WWN appears in the output of the switchShow command NOTE When security mode is enabled this command can be issued only from the primary FCS switch Operands none Examples To display the switch WWN See also switchShow wwn switch admin wwn 10 00 00 60 69 00 54 e9 ...

Page 750: ...n must be enabled using the cfgEnable command NOTE When security mode is enabled this command can be issued only from the primary FCS switch Operands The following operands are required Examples To add aliases for three disk arrays to Blue_zone See also zoneCreate zoneDelete zoneRemove zoneShow zoneAdd zoneName Specify the name of an existing zone in quotation marks This operand is required member...

Page 751: ...ify a world wide name as eight hex numbers separated by colons for example 10 00 00 60 69 00 00 8a Zoning compares the WWN with the node and port names presented by a device in a login frame FLOGI or PLOGI When a zone member is specified by node name then all ports on that device are in the zone When a zone member is specified by port name then only that single device port is in the zone Specify a...

Page 752: ...ata transfer to a port When security mode is enabled this command can be issued only from the primary FCS switch Operands The following operands are required Examples To create three zones using a combination of port numbers and zone aliases See also zoneAdd zoneDelete zoneRemove zoneShow zonename Specify the name of an existing zone in quotation marks This operand is required member Specify a mem...

Page 753: ... be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security mode is enabled this command can be issued only from the primary FCS switch Operands This command has the following operand Examples To delete the zone Blue_zone See also zo...

Page 754: ... a member to a zone alias aliCreate Create a zone alias aliDelete Delete a zone alias aliRemove Remove a member from a zone alias aliShow Print zone alias information fazoneAdd Add a member to a fabric assist zone fazoneCreate Create a fabric assist zone fazoneDelete Delete a fabric assist zone fazoneShow Print Fabric Assist Zone information cfgClear Clear all zone configurations cfgDisable Disabl...

Page 755: ...Fabric OS 5 x command reference guide 755 cfgDisable cfgEnable cfgSize cfgTransAbort faZoneAdd faZoneCreate faZoneDelete faZoneShow ...

Page 756: ...the defined configuration For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command See the zoneCreate command for more information on name and member specifications NOTE When security mode is enabled this command can be issued only ...

Page 757: ...Fabric OS 5 x command reference guide 757 See also cfgAdd cfgClear cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow zoneObjectRename ...

Page 758: ... object is completely removed from the database You can use this command for all zone object types including cfg zone and alias This command changes the defined configuration For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command ...

Page 759: ...one White_zone 1 3 1 4 alias array1 21 00 00 20 37 0c 76 8c 21 00 00 20 37 0c 71 02 alias array2 21 00 00 20 37 0c 76 22 21 00 00 20 37 0c 76 28 alias loop1 21 00 00 20 37 0c 76 85 21 00 00 20 37 0c 71 df switch admin zoneObjectExpunge White_zone switch admin cfgShow Defined configuration cfg USA_cfg Red_zone Blue_zone zone Blue_zone 1 1 array1 1 2 array2 zone Red_zone 1 0 loop1 alias array1 21 00...

Page 760: ...configuration For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command See the zoneCreate command for more information on name and member specifications NOTE When security mode is enabled this command can be issued only from the pri...

Page 761: ...Fabric OS 5 x command reference guide 761 See also cfgAdd cfgClear cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow zoneObjectCopy ...

Page 762: ...leted This command changes the defined configuration For the change to be preserved across switch reboots it must be saved to flash memory using the cfgSave command For the change to become effective an appropriate zone configuration must be enabled using the cfgEnable command NOTE When security mode is enabled this command can be issued only from the primary FCS switch Operands The following oper...

Page 763: ...ic OS 5 x command reference guide 763 Examples To remove array2 from Blue_zone See also zoneAdd zoneCreate zoneDelete zoneShow switch admin zoneremove Blue_zone array2 switch admin zoneremove Blue_zone 2 20 ...

Page 764: ...layed NOTE When security mode is enabled this command can be issued only from the primary FCS switch Operands The following operand is optional Examples To display all zones beginning with the letters A through C zoneShow pattern A POSIX style regular expression used to match zone configuration names The pattern must be enclosed in quotation marks Patterns can contain A question mark which matches...

Page 765: ...Fabric OS 5 x command reference guide 765 See also zoneAdd zoneCreate zoneDelete zoneRemove ...

Page 766: ...766 Fabric OS commands ...

Page 767: ...oning QuickLoop Extended Fabrics Fabric Watch Trunking or Performance Monitoring see the HP StorageWorks Fabric OS 5 x features overview Advanced zoning commands The commands listed in Table 20 are available with the purchase of an HP Advanced Zoning license key Table 20 Zoning commands Command Description Zone Alias aliAdd Adds a member to a zone alias aliCreate Creates a zone alias aliDelete Del...

Page 768: ...ransAbort Aborts the current zoning transaction zoneObjectCopy Copies a zone object zoneObjectExpunge Expunges a zone object zoneObjectRename Renames a zone object Table 20 Zoning commands continued Command Description Table 21 QuickLoop fabric assist mode commands Command Description faZoneAdd Adds members to an existing QuickLoop Fabric Assist zone faZoneCreate Creates a QuickLoop Fabric Assist ...

Page 769: ...le 23 Fabric watch commands Command Description fwClassInit Initialize all classes under Fabric Watch fwConfigReload Reload the Fabric Watch configuration fwConfigure Display and enable modification of the Fabric Watch configuration and status fwShow Display the thresholds monitored by Fabric Watch fwAlarmsFilterSet Enable or disable alarms for Fabric Watch fwAlarmsFilterShow Display alarm filteri...

Page 770: ...e performance monitoring settings from flash memory perfCfgRestore Restore performance monitoring settings from flash memory perfCfgSave Save the current performance monitoring settings to flash memory perfClearEEMonitor Clear statistics counters of an end to end EE monitor on a port perfClearFilterMonitor Clear statistics counters of a filter based monitor perfClrAlpaCrc Clear an AL_PA device CRC...

Page 771: ...all changes to the defined database that have not been saved secPolicyActivate Apply defined policy set to all switches in the fabric secPolicyAdd Add members to an existing policy secPolicyCreate Create a new policy secPolicyDelete Delete an existing policy secPolicyDump Display all members of existing policies secPolicyFCSMove Move a member in the FCS policy secPolicyRemove Remove members from a...

Page 772: ...772 Licensed product commands ...

Page 773: ...m the primary FCS switch aliDelete Must be run from the primary FCS switch aliRemove Must be run from the primary FCS switch aliShow Must be run from the primary FCS switch cfgAdd Must be run from the primary FCS switch cfgClear Must be run from the primary FCS switch cfgCreate Must be run from the primary FCS switch cfgDelete Must be run from the primary FCS switch cfgDisable Must be run from the...

Page 774: ...e primary FCS switch secFabricShow Must be run from the primary FCS switch secModeDisable Must be run from the primary FCS switch secNonFcsPasswd Must be run from the primary FCS switch secPolicyAbort Must be run from the primary FCS switch secPolicyActivate Must be run from the primary FCS switch secPolicyAdd Must be run from the primary FCS switch secPolicyCreate Must be run from the primary FCS...

Page 775: ...ver s IP address on the primary FCS switch wwn This command can be run on all switches to view the WWN With security enabled the WWN of a switch cannot be modified zoneAdd Must be run from the primary FCS switch zoneCreate Must be run from the primary FCS switch zoneDelete Must be run from the primary FCS switch zoneRemove Must be run from the primary FCS switch zoneShow Must be run from the prima...

Page 776: ...776 Exclusive primary FCS commands ...

Page 777: ...ys the SNMP agent configuration aliasDelete Deletes a port from all local groups aliasJoin Creates a multicast alias group of N_Ports If the group already exists the N_Ports are added to the existing group aliasPurge Removes an alias group aliasShow Displays local alias server information aptPolicy Changes or displays the Advanced Performance Tuning APT policy authUtil Displays and sets the authen...

Page 778: ...fied module diagHelp Displays diagnostic command information dlsReset Disables the dynamic load sharing DLS option dlsSet Enables the dynamic load sharing DLS option dlsShow Display the setting of the dynamic load sharing DLS option dnsConfig Sets or displays domain name service DNS parameters enclosureShow Displays attributes of the switch enclosure errClear Clears all error log messages for all ...

Page 779: ...Enables the FCPD debug information log debug command fcpLogShow Displays the FCPD debug information log debug command fcpProbeShow Displays the Fibre Channel Protocol FCP probe information fcpRlsShow Display the Fibre Channel Protocol FCP Read Link Status RLS information fdmiCacheShow Displays abbreviated remote FDMI device information according to remote domain ID fdmiShow Displays detailed FDMI ...

Page 780: ... Sets the link operating mode for a network interface ifModeShow Displays the link operating mode for a network interface interfaceShow Displays FSPF interface information interopMode Enables or disables HP switch interoperability with switches from other manufacturers iodReset Turns off the in order delivery IOD option iodSet Enables the in order delivery IOD option iodShow Displays the in order ...

Page 781: ...S platform database on all switches in the fabric msPlMgmtActivate Activates the Management Server MS platform service msPlMgmtDeactivate Deactivates the Management Server MS platform service msTdDisable Disables the Management Server MS topology discovery service msTdEnable Enables the Management Server MS topology discovery service msTdReadConfig Displays the status of Management Server MS topol...

Page 782: ...the switch portCamShow Displays port based filter CAM utilization portCfg Sets a port s configuration to be disabled or enabled portCfgDefault Restores the port configuration to default values portCfgEPort Enables or disables a port from becoming an E_Port portCfgGPort Designates a port as a G_Port portCfgISLMode Enables or disables ISL R_RDY mode on a port portCfgLongDistance Configures a port to...

Page 783: ...rtLogShowPort Displays the port log of specified port with page breaks portLogTypeDisable Disables the port log of a specified type portLogTypeEnable Enables the port log of a specified type portName Assigns or displays a port name portPerfShow Displays port throughput performance in bytes kilobytes or megabytes portRouteShow Displays routing tables for the specified port portShow Displays port st...

Page 784: ... Enables or disables ESD mode setGbicMode Enables or disables media mode setMediaMode Enables or disables media mode setModem Enables or disables modem dial in to a control processor CP setSfpMode Enables or disables media mode setVerbose Specifies module verbose level sfpShow Displays serial ID SFP information shellFlowControlDisable Disables XON XOFF flow control on the console serial ports shel...

Page 785: ...witch switchName Displays or sets the switch name switchShow Displays switch and port status switchStatusPolicySet Sets the policy parameters that determine overall switch status switchStatusShow Displays the policy parameters that determine overall switch status switchStatusShow Displays overall switch status switchUptime Displays the amount of time the switch has been operating syslogdIpAdd Adds...

Page 786: ... sets the system time zone upTime Displays how long the switch has been up uRouteConfig Configures a static route uRouteRemove Removes a static route uRouteShow Displays unicast routing information userConfig Manages user accounts version Displays firmware version information voltShow Displays current level of the voltage sensors on a system wwn Displays a switch world wide name WWN zoneHelp Displ...

Page 787: ... supported on the standby CP The following commands are supported when logged into the standby CP Table 29 Commands supported on the standby CP Command Description date Print set the system date and time errClear Clear error log errDump Print error log no page breaks fastBoot Reboot this switch bypassing POST firmwareCommit Commit firmware to stable storage firmwareDownload Download firmware into ...

Page 788: ... Display the current login session details pdShow Display information from panic dump file reboot Reboot the standby CP saveCore FTP or remove core files generated by daemons switchName Print this switch s name tsTimeZone Display time zone upTime Print how long switch has been up version Print firmware version Table 29 Commands supported on the standby CP continued Command Description ...

Page 789: ...command groups under supportshow and which Fabric OS or Linux commands are executed by that group NOTE Many of the commands executed by supportShow are intended for support use only These commands are not intended for end users supportShowCfgShow Display which groups of commands are enabled to display under supportShow supportShowCfgEnable Enable a group of commands to display under supportShow su...

Page 790: ...stryshow services nsShow nsAllShow nscamShow fdmiCacheShow ficonDbg dump rnid ficonDbg log ficonShow ilir ficonShow lirr ficonShow rlir ficonShow rnid fdmiShow nsShow nsAllShow nscamShow security secModeShow secPolicyDump secStatsShow secFabricShow secModeShow secPolicyDump secStatsShow secFabricShow network ipAddrShow ifshow ipstatshow udpstatshow tcpstatshow inetstatshow mbufshow arpshow routesh...

Page 791: ...anShow licenseShow portFlagsShow portCfgShow sfpShow portErrShow fwSamShow agtCfgShow slotShow chassisShow switchStatusPolicyShow fwAlarmsFilterShow timeout historyShow configShow extend bloomlistdisplay bloomfdetshow bloomramdump ptbufshow ptcreditshow ptDataShow ptPhantomShow ptPropShow ptStatsShow filter filtershow filterportshow perfmon ps_dump ps_dump a n port Table 30 supportShow command gro...

Page 792: ...pvr 4011 0145 bogomips 199 47 machine Brocade Silkworm plb bus clock 100MHz pci bus clock 33MHz proc devices proc devices Character devices 1 mem 2 pty 3 ttyp 4 ttyS 5 cua 7 vcs 10 misc 89 i2c 90 mtd 128 ptm 136 pts 162 raw 245 swd 246 ham 247 fc 248 fc switch 249 fabsys 250 fss_kt 251 fss_data 252 fss_mgmt 253 portlog 254 platform Block devices 1 ramdisk 3 ide0 7 loop proc filesystems proc filesy...

Page 793: ...tal 0 kB SwapFree 0 kB proc modules proc modules dubby module 582614 2 chubby module 3128618 126 dubby module dfs 5458 1 dubby module consolelog module 8539 0 unused panicdump module 15279 0 chubby module consolelog module xfsnotificationhandler 4858 0 unused proc mounts proc mounts rootfs rootfs rw 0 0 dev hda1 xfs rw noatime 0 0 proc proc proc rw 0 0 none dev pts devpts rw 0 0 none tmp ramfs rw ...

Page 794: ...65 168 160 7 7 1 arp_cache 2 30 128 1 1 1 blkdev_requests 128 160 96 4 4 1 xfs_chashlist 193 404 16 2 2 1 xfs_ili 2004 5668 152 135 218 1 xfs_ifork 0 0 56 0 0 1 xfs_efi_item 0 12 328 0 1 1 xfs_efd_item 0 12 328 0 1 1 output truncated proc stat proc stat cpu 184683 47107 88647 15558673 cpu0 184683 47107 88647 15558673 page 54635 71305 swap 0 0 intr 4154525 0 591 2696197 0 0 0 0 0 0 0 0 1520 343900 ...

Page 795: ...proc uptime 158791 21 155710 77 proc version proc version Linux version 2 4 19 swrel sierra gcc version 2 95 3 20010112 prerelease 1 Wed Mar 26 00 04 35 PST 2003 Table 31 proc entry information displayed continued Proc display command Proc example display ...

Page 796: ...796 supportShow reference ...

Page 797: ...agement ANSI American National Standards Institute arbitrated loop A shared 100 Mb sec Fibre Channel transport structured as a loop Can support up to 126 devices and one fabric attachment See also topology arbitration A method of gaining orderly access to a shared loop topology area number In HP Fabric OS v4 0 and above ports on a switch are assigned a logical area number Port area numbers can be ...

Page 798: ...large fabric A switch can be set to beacon by a CLI command or through HP Advanced Web Tools beginning running disparity The disparity at the transmitter or receiver when the special character associated with an ordered set is encoded or decoded See also disparity BER Bit error rate The rate at which bits are expected to be received in error Expressed as the ratio of error bits to total bits trans...

Page 799: ... of frame delivery or nondelivery Class 4 service A connection oriented service that allows fractional parts of the bandwidth to be used in a virtual circuit Class 6 service A connection oriented multicast service geared toward video broadcasts between a central server and clients Class F service The class of frame switching service for a direct connection between two switches allowing communicati...

Page 800: ...te for a frame to be selected as soon as the destination address is received See also route D_ID Destination identifier A 3 byte field in the frame header used to indicate the address identifier of the N_Port to which the frame is headed DAS Direct attached storage data word A type of transmission word that occurs within frames The frame header data field and CRC all consist of data words See also...

Page 801: ...time allowed for a round trip transmission before an error is declared See also R_A_TOV RR_TOV E_Port Expansion port A standard Fibre Channel mechanism that enables switches to network with each other creating an ISL See also ISL ECCN Export classification control number A government classification of encryption For example SSH is in the high encryption category number 5x02 and therefore has certa...

Page 802: ... is being denied perhaps because a class is not supported there is an invalid header or no N_Port is available fabric A collection of Fibre Channel switches and devices such as hosts and storage Also referred to as a switched fabric See also cascade SAN topology fabric application platform A device that enables fabric based storage applications such as mirroring data migration snapshots and virtua...

Page 803: ...ated loop standard defined by ANSI Defined on top of the FC PH standards FC AV Fibre Channel audio visual FC CT Fibre Channel common transport FC FG Fibre Channel generic requirements FC FLA The Fibre Channel fabric loop attach standard defined by ANSI FC FS Fibre Channel framing and signaling FC GS Fibre Channel generic services FC GS 2 Fibre Channel generic services second generation FC GS 3 Fib...

Page 804: ...security parameters and configuration data for all switches in the fabric They also act as a set of backup switches to the primary FCS switch See also backbone fabric primary FCS switch FC SW 2 The second generation Fibre Channel Switch Fabric standard defined by ANSI Specifies tools and algorithms for the interconnection and initialization of Fibre Channel switches to create a multiswitch Fibre C...

Page 805: ...ontents without power FLOGI Fabric login The process by which an N_Port determines whether a fabric is present and if so exchanges service parameters with it See also PLOGI FOTP Fiber Optic Test Procedure Standards developed and published by the Electronic Industries Association EIA under the EIA RS 455 series of standards FPD Field programmable device Interchangeable with PLD FPGA Field programma...

Page 806: ...ftware For example an ATM gateway can be used to connect a Fibre Channel link to an ATM connection GBIC Gigabit interface converter A removable serial transceiver module that allows gigabaud physical level transport for Fibre Channel and gigabit Ethernet Gb s Gigabits per second 1 062 500 000 bits second GB sec Gigabytes per second 1 062 500 000 bytes second GLM Gigabit Link Module A semitranspare...

Page 807: ...rts Fibre Channel Layer 4 FCP Over TCP IP It is a gateway to gateway protocol in which TCP IP switching and routing components enhance replace Fibre Channel fabric IFL Interfabric link A connection between a router and an edge fabric Architecturally these can be of type EX_Port to E_Port or EX_Port to EX_Port in band Transmission of management protocol over the Fibre Channel initiator A server or ...

Page 808: ...umeric value shared between two entities and used to control a cryptographic algorithm Usually selected from a large pool of possible keys to make unauthorized identification of the key difficult See also key pair key pair In public key cryptography a pair of keys consisting of an entity s public and private key The public key can be publicized but the private key must be kept secret See also publ...

Page 809: ...Works 1 GB switches loop circuit A temporary bidirectional communication path established between L_Ports loop failure Loss of signal within a loop for any period of time or loss of synchronization for longer than the timeout value Loop_ID A hexadecimal value representing one of the 127 possible AL_PA values in an arbitrated loop loop initialization The logical procedure used by an L_Port to disco...

Page 810: ...ng FC routers In a data network this would simply be called the network However an additional term is required to specify the difference between a single fabric network SAN a multifabric network without cross fabric connectivity dual redundant fabric SAN and a multifabric network with connectivity meta SAN metric A relative value assigned to a route to aid in calculating the shortest path 1000 1 G...

Page 811: ...See also N_Port Nx_Port node A Fibre Channel device that contains an N_Port or NL_Port node count The number of nodes attached to a fabric node name The unique identifier for a node communicated during login and port discovery Nonparticipating Mode A mode in which an L_Port in a loop is inactive and cannot arbitrate or send frames but can retransmit received transmissions This mode is entered if t...

Page 812: ...assive copper A low cost copper Fibre Channel connection allowing distances up to 13 meters between devices path selection The selection of a transmission path through the fabric HP switches use the FSPF protocol See also FSPF payload A Fibre Channel frame has a header and a payload The payload contains the information being transported by the frame it is determined by the higher level service or ...

Page 813: ...rt log A record of all activity on a switch kept in volatile memory port log dump A view of what happens on a switch from the switch s point of view The portLogDump command is used to read the port log port name A user defined alphanumeric name for a port port swapping Port swapping is the ability to redirect a failed port to another port This feature is available in Fabric OS v4 1 0 and higher po...

Page 814: ...rivate NL_Ports public NL_Port An NL_Port that logs in to the fabric can function within either a public or a private loop and can communicate with either private or public NL_Ports QLA A type of Fibre Channel controller QLFA QuickLoop Fabric Assist Arbitrated loop technology QoS Quality of service quad A group of four adjacent ports that share a common pool of frame buffers queue A mechanism for ...

Page 815: ...into a link or system Can see optical power or to electrical power in a specified frequency range RLS Read Link Status route As it applies to a fabric the communication path between two switches Might also apply to the specific path taken by an individual frame from source to destination See also FSPF routing The assignment of frames to specific switch ports according to frame destination RR_TOV R...

Page 816: ... over different kinds of links SDRAM The main memory for a switch sectelnet A protocol similar to telnet but with encrypted passwords for increased security Secure Fabric OS An optionally licensed HP feature that provides advanced centralized security for a fabric security policy Rules that determine how security is implemented in a fabric Security policies can be customized through HP Secure Fabr...

Page 817: ...gement Initiative Specification Defines the interface that allows storage management systems to manage and monitor storage area network SAN resources SNA SDLC Systems Network Architecture Synchronous Data Link Control A structure for transferring data among a variety of computing platforms SNMP Simple Network Management Protocol An Internet management protocol that uses either IP for network level...

Page 818: ... Syslog daemon Used to forward error messages T10 A standards committee chartered with creating standards for SCSI T11 A standards committee chartered with creating standards for Fibre Channel tachyon A chip that supports FC 0 through FC 2 on a single chip target A storage device on a Fibre Channel network See also initiator TC Track changes TCP IP Transmission Control Protocol Internet Protocol t...

Page 819: ...s The ports in a set of trunked ISLs TS Time Server TTL Time to live The number of seconds an entry exists in cache before it expires tunneling A technique for enabling two networks to communicate when the source and destination hosts are both on the same type of network but are connected by a different type of network TX Transmit U_Port Universal port A switch port that can operate as a G_Port E_...

Page 820: ...nications between computers and can accommodate noisy data communications through error detection and correction retransmission algorithms xlate domain Translate domain A router virtual domain that represents an entire fabric Device connectivity can be achieved from one fabric to another over the router and through this virtual domain without merging the two fabrics Also known as phantom domains z...

Page 821: ...P aliAdd 35 Advanced Zoning license exclusive primary FCS commands zoning aliasDelete 37 aliasJoin 38 aliasPurge 40 aliasShow 41 aliCreate 42 Advanced Zoning license exclusive primary FCS commands zoning aliDelete 44 Advanced Zoning license exclusive primary FCS commands zoning aliRemove 45 Advanced Zoning license exclusive primary FCS commands zoning aliShow 47 Advanced Zoning license exclusive p...

Page 822: ...fault 113 SNMP configDownload 115 configShow 118 configUpload 120 SNMP configuration arbitrated loop parameters 127 authentication 52 777 fabric parameters 128 NS operation parameters 127 portlog events enable 128 RSCN transmission mode 127 system services 128 virtual channel settings 126 zoning operation parameters 126 configure 123 SNMP conventions document 14 text symbols 14 crossPortTest 132 D...

Page 823: ...faZoneRemove 207 faZoneShow 209 Fabric OS Command Line Interface 18 fabric parameters configuration 128 Fabric Watch 99 Fabric Watch license 700 Fabric Watch commands 769 fwAlarmFilterSet 257 fwAlarmsFilterShow 258 fwClassInit 259 fwConfigReload 260 fwConfigure 261 fwFruCfg 267 fwHelp 269 fwMailCfg 270 fwPortDetailShow 273 fwSamShow 276 fwSet 277 fwSetToCustom 278 fwSetToDefault 279 fwShow 280 fab...

Page 824: ...se fwHelp 269 Fabric Watch license fwMailCfg 270 Fabric Watch license fwPortDetailShow 273 Fabric Watch license fwSamShow 276 Fabric Watch license fwSet 277 Fabric Watch license fwSetToCustom 278 Fabric Watch license fwSetToDefault 279 Fabric Watch license fwShow 280 Fabric Watch license H h 283 standby CP commands haDisable 284 haDump 285 standby CP commands haEnable 287 haFailover 288 haShow 289...

Page 825: ...MUA 17 myId 360 standby CP commands N nbrStateShow 361 nbrStatsClear 362 nodeFind 365 NS operation parameters configuration 127 nsAliasShow 368 nsAllShow 372 nscamShow 374 nsZoneMember 382 P passwd 386 exclusive primary FCS commands pathInfo 388 pdShow 393 standby CP commands perfAddEEMonitor 395 Performance Monitor license perfAddIPMonitor 397 Performance Monitor license perfAddReadMonitor 399 Pe...

Page 826: ...able 469 SNMP portEnable 470 SNMP portErrShow 471 portFlagsShow 473 SNMP portLedTest 475 portlog events enable configuration 128 portLogClear 476 portLogConfigShow 477 portLogDump 478 portLogDumpPort 480 portLogEventShow 482 portLoginShow 484 portLogPdisc 486 portLogReset 489 portLogResize 490 portLogShow 491 portLogShowPort 496 portLogTypeDisable 498 portLogTypeEnable 499 portLoopbackTest 500 por...

Page 827: ...ric OS secPolicyDelete 589 exclusive primary FCS commands Secure Fabric OS secPolicyDump 592 exclusive primary FCS commands Secure Fabric OS secPolicyFcsMove 595 exclusive primary FCS commands Secure Fabric OS secPolicyRemove 597 exclusive primary FCS commands Secure Fabric OS secPolicySave 600 exclusive primary FCS commands Secure Fabric OS secPolicyShow 601 exclusive primary FCS commands Secure ...

Page 828: ... 248 h 283 haDump 285 haShow 289 help 293 ifModeSet 302 ifModeShow 304 killTelnet 320 memShow 337 myId 360 pdShow 393 reboot 547 saveCore 549 switchName 689 tsClockServer 727 upTime 736 version 745 746 state entries 190 statsClear 665 statsTest 666 stopPortTest 668 Subscriber s choice HP 15 supportFtp 669 supportSave 671 supportShow 674 supportShow command groups 789 supportShow control commands 7...

Page 829: ...eDelete 753 Advanced Zoning license exclusive primary FCS commands zoning zoneHelp 754 Advanced Zoning license zoning zoneObjectCopy 756 Advanced Zoning license zoning zoneObjectExpunge 758 Advanced Zoning license zoning zoneObjectRename 760 Advanced Zoning license zoning zoneRemove 762 Advanced Zoning license exclusive primary FCS commands zoning zoneShow 764 Advanced Zoning license exclusive pri...

Page 830: ...830 Index ...

Reviews: