100 Fabric OS commands
Unless the chassis is currently configured as Option 1 (a single 128-port switch with blade IDs 4 and 17
and CP blade IDs 5 and 16), both CP blades should always contain firmware that supports this
command. Use of earlier versions will adversely affect switch operation.
Because this is a disruptive operation and has profound effect on the behavior of the chassis, it needs to
be used selectively.
Users running secure mode should be particularly careful in using this command to change the number of
domains on the local chassis, because security is disabled on all resulting local switches. These switches
are not able to participate in a secure fabric until secure mode is restored. Therefore, the fabric should
have a primary FCS outside this chassis, to manage security throughout the fabric during this transition.
Operands
The operands are as follows:
Examples
To display the current configuration option on an HP StorageWorks SAN Director 2/128 and to change
the option:
-f
If specified, forces configuration changes without asking for confirmation or
requesting a configuration upload.
option
Specifies the new configuration option to apply to the chassis. This operand is
optional; if omitted, this command displays the current configuration option
and a list of all valid options. Values include:
1
2
3
4
5
One 128-port switch (blade ID 4, 17 on slots 1 through 4 and 7
through 10; blade ID 5, 16 on slots 5 and 6)
Two 64-port switches (blade ID 4 on slots 1 through 4 and 7 through
10; blade ID 5 on slots 5 and 6)
Two 64-port switches (blade ID 4 on slots 1 through 4, blade ID 2 on
slots 7 through 10; blade ID 5 on slots 5 and 6)
Two 64-port switches (blade ID 2 on slots 1 through 4, blade ID 4 on
slots 7 through 10; blade ID 5 on slots 5 and 6)
One 256-port switch (blade ID 17, 18 on slots 1 through 4 and 7
through 10; blade ID 16 on slots 5 and 6)
Summary of Contents for StorageWorks 2/64 - Core Switch
Page 12: ...12 Contents ...
Page 16: ...16 ...
Page 20: ...20 Fabric OS command line interface ...
Page 36: ...36 Fabric OS commands See also aliCreate aliDelete aliRemove aliShow ...
Page 48: ...48 Fabric OS commands See also aliAdd aliCreate aliDelete aliRemove ...
Page 51: ...Fabric OS 5 x command reference guide 51 See also dlsReset dlsSet dlsShow switchDisable ...
Page 80: ...80 Fabric OS commands cfgRemove cfgSave cfgShow ...
Page 82: ...82 Fabric OS commands See also cfgDisable cfgEnable cfgSave ...
Page 96: ...96 Fabric OS commands cfgShow ...
Page 105: ...Fabric OS 5 x command reference guide 105 Examples To display all FRUs for a switch ...
Page 122: ...122 Fabric OS commands See also configDefault configDownload configShow configure ...
Page 150: ...150 Fabric OS commands See also burninLevel setEsdMode setGbicMode setSplbMode ...
Page 171: ...Fabric OS 5 x command reference guide 171 See also errDelimiterSet errFilterSet errShow ...
Page 175: ...Fabric OS 5 x command reference guide 175 ...
Page 191: ...Fabric OS 5 x command reference guide 191 See also fabricLog fabStateClear fabStateShow ...
Page 208: ...208 Fabric OS commands See also faZoneAdd faZoneCreate faZoneDelete faZoneShow ...
Page 217: ...Fabric OS 5 x command reference guide 217 See also fcPing fcpLogDisable fcpLogEnable ...
Page 219: ...Fabric OS 5 x command reference guide 219 See also portLoginShow portLogShow ...
Page 240: ...240 Fabric OS commands See also firmwareDownload firmwareRestore ...
Page 256: ...256 Fabric OS commands See also bcastShow topologyShow uRouteShow ...
Page 266: ...266 Fabric OS commands See also fwClassInit fwConfigReload fwShow ...
Page 298: ...298 Fabric OS commands See also historyLastShow ...
Page 315: ...Fabric OS 5 x command reference guide 315 See also ipAddrShow ...
Page 357: ...Fabric OS 5 x command reference guide 357 See also msTdEnable msTdReadConfig ...
Page 364: ...364 Fabric OS commands See also interfaceShow portShow switchShow ...
Page 373: ...Fabric OS 5 x command reference guide 373 See also nsShow switchShow ...
Page 376: ...376 Fabric OS commands nsShow switchShow ...
Page 394: ...394 Fabric OS commands See also portLogDump saveCore ...
Page 452: ...452 Fabric OS commands See also portCfgShow ...
Page 458: ...458 Fabric OS commands ...
Page 504: ...504 Fabric OS commands portCfgDefault portShow ...
Page 532: ...532 Fabric OS commands slotPowerOff slotPowerOn slotShow ...
Page 536: ...536 Fabric OS commands See also chassisShow fanShow ...
Page 542: ...542 Fabric OS commands See also qloopAdd qloopCreate qloopDelete qloopShow ...
Page 554: ...554 Fabric OS commands See also none ...
Page 565: ...Fabric OS 5 x command reference guide 565 See also secPolicyDump secPolicyShow ...
Page 591: ...Fabric OS 5 x command reference guide 591 secPolicyRemove secPolicySave secStatsShow ...
Page 673: ...Fabric OS 5 x command reference guide 673 supportShow traceDump traceFtp traceTrig ...
Page 715: ...Fabric OS 5 x command reference guide 715 traceFtp traceTrig ...
Page 722: ...722 Fabric OS commands See also agtCfgSet agtCfgShow trackChangesHelp trackChangesShow ...
Page 725: ...Fabric OS 5 x command reference guide 725 See also portCfgTrunkPort switchCfgTrunk trunkShow ...
Page 765: ...Fabric OS 5 x command reference guide 765 See also zoneAdd zoneCreate zoneDelete zoneRemove ...
Page 766: ...766 Fabric OS commands ...
Page 772: ...772 Licensed product commands ...
Page 776: ...776 Exclusive primary FCS commands ...
Page 796: ...796 supportShow reference ...
Page 830: ...830 Index ...