Fabric OS 5.x command reference guide 125
NOTE:
The R_A_TOV, E_D_TOV, WAN_TOV, and MAX_HOPS configuration parameters are
inter-related. Assigning a specific value to one or more of these parameters can change the range of
allowed values that can be assigned to the other parameters. As a result, the user might not be able to set
all the values within the range displayed against each parameter. To reduce problems, the configuration
utility validates the modified parameter values and prompts the user to re-enter some values, if the
validation check fails.
MAX_HOPS
Maximum hops (MAX_HOPS) is an integer that denotes the
upper limit on the number of hops a frame might have to traverse
to reach any destination port from any source port across the
fabric.
Data Field Size
The data field size specifies the largest possible value, in bytes, and
advertises this value to other switches in the fabric during construction
of the fabric as well as to other devices when they connect to the
fabric. Setting this to a value smaller than 2112 might result in
decreased performance.
Sequence-Level Switching
When sequence-level switching is set to 1, frames of the same
sequence from a particular source are transmitted as a group. When
this feature is set to 0, frames are transmitted interleaved among
multiple sequences.
Under normal conditions, sequence-level switching should be disabled
for better performance. However, some host adapters have
performance issues when receiving interleaved frames from multiple
sequences. When there are such devices attached to the fabric,
sequence-level switching should be enabled.
Disable Device Probing
When disable device probing is set to 1, devices that do not register
with the name server are not present in the name server data base. Set
this mode only if the switch N_Port discovery process (PLOGI, PRLI,
INQUIRY) causes an attached device to fail.
Suppress Class F Traffic
When this mode is set to 1, all Class F interswitch frames are
transmitted as Class 2 frames. This is to support remote fabrics that
involve ATM gateways, which don't support class F traffic.
Switch PID Format
The formats are as follows:
0
Native PID format (16 based, 16 port format), for fabrics
with legacy low-count-port switches.
1
Core PID format (0 based, 256 port format), preferred
mode for mixed fabrics with legacy and new switches.
2
Extended edge PID format (16 based, 256 port format),
used in mixed fabrics with legacy and new switches to
avoid need to reboot host systems when static PID binded is
used.
Per-frame Route Priority
In addition to the eight virtual channels used in frame routing priority,
support is also available for per-frame-based prioritization when this
value is set. When Per-frame Route Priority is set to 1, the virtual
channel ID is used in conjunction with a frame header to form the final
virtual channel ID.
Long Distance Fabric
When this mode is set to 1, ISLs in a fabric can be up to 100 km long.
The exact distance level is determined by the per-port configuration on
the E_Ports of each ISL. Both E_Ports in an ISL must be configured to run
the same long-distance level; otherwise, the fabric will be segmented.
The Extended Fabric License is required to set this mode.
Summary of Contents for StorageWorks 2/64 - Core Switch
Page 12: ...12 Contents ...
Page 16: ...16 ...
Page 20: ...20 Fabric OS command line interface ...
Page 36: ...36 Fabric OS commands See also aliCreate aliDelete aliRemove aliShow ...
Page 48: ...48 Fabric OS commands See also aliAdd aliCreate aliDelete aliRemove ...
Page 51: ...Fabric OS 5 x command reference guide 51 See also dlsReset dlsSet dlsShow switchDisable ...
Page 80: ...80 Fabric OS commands cfgRemove cfgSave cfgShow ...
Page 82: ...82 Fabric OS commands See also cfgDisable cfgEnable cfgSave ...
Page 96: ...96 Fabric OS commands cfgShow ...
Page 105: ...Fabric OS 5 x command reference guide 105 Examples To display all FRUs for a switch ...
Page 122: ...122 Fabric OS commands See also configDefault configDownload configShow configure ...
Page 150: ...150 Fabric OS commands See also burninLevel setEsdMode setGbicMode setSplbMode ...
Page 171: ...Fabric OS 5 x command reference guide 171 See also errDelimiterSet errFilterSet errShow ...
Page 175: ...Fabric OS 5 x command reference guide 175 ...
Page 191: ...Fabric OS 5 x command reference guide 191 See also fabricLog fabStateClear fabStateShow ...
Page 208: ...208 Fabric OS commands See also faZoneAdd faZoneCreate faZoneDelete faZoneShow ...
Page 217: ...Fabric OS 5 x command reference guide 217 See also fcPing fcpLogDisable fcpLogEnable ...
Page 219: ...Fabric OS 5 x command reference guide 219 See also portLoginShow portLogShow ...
Page 240: ...240 Fabric OS commands See also firmwareDownload firmwareRestore ...
Page 256: ...256 Fabric OS commands See also bcastShow topologyShow uRouteShow ...
Page 266: ...266 Fabric OS commands See also fwClassInit fwConfigReload fwShow ...
Page 298: ...298 Fabric OS commands See also historyLastShow ...
Page 315: ...Fabric OS 5 x command reference guide 315 See also ipAddrShow ...
Page 357: ...Fabric OS 5 x command reference guide 357 See also msTdEnable msTdReadConfig ...
Page 364: ...364 Fabric OS commands See also interfaceShow portShow switchShow ...
Page 373: ...Fabric OS 5 x command reference guide 373 See also nsShow switchShow ...
Page 376: ...376 Fabric OS commands nsShow switchShow ...
Page 394: ...394 Fabric OS commands See also portLogDump saveCore ...
Page 452: ...452 Fabric OS commands See also portCfgShow ...
Page 458: ...458 Fabric OS commands ...
Page 504: ...504 Fabric OS commands portCfgDefault portShow ...
Page 532: ...532 Fabric OS commands slotPowerOff slotPowerOn slotShow ...
Page 536: ...536 Fabric OS commands See also chassisShow fanShow ...
Page 542: ...542 Fabric OS commands See also qloopAdd qloopCreate qloopDelete qloopShow ...
Page 554: ...554 Fabric OS commands See also none ...
Page 565: ...Fabric OS 5 x command reference guide 565 See also secPolicyDump secPolicyShow ...
Page 591: ...Fabric OS 5 x command reference guide 591 secPolicyRemove secPolicySave secStatsShow ...
Page 673: ...Fabric OS 5 x command reference guide 673 supportShow traceDump traceFtp traceTrig ...
Page 715: ...Fabric OS 5 x command reference guide 715 traceFtp traceTrig ...
Page 722: ...722 Fabric OS commands See also agtCfgSet agtCfgShow trackChangesHelp trackChangesShow ...
Page 725: ...Fabric OS 5 x command reference guide 725 See also portCfgTrunkPort switchCfgTrunk trunkShow ...
Page 765: ...Fabric OS 5 x command reference guide 765 See also zoneAdd zoneCreate zoneDelete zoneRemove ...
Page 766: ...766 Fabric OS commands ...
Page 772: ...772 Licensed product commands ...
Page 776: ...776 Exclusive primary FCS commands ...
Page 796: ...796 supportShow reference ...
Page 830: ...830 Index ...