Diagnostics
66
52
Obtain event codes from the Embedded Web Server Event Log.
Note:
If multiple event codes are found, note all codes and associated severity levels.
Record the date, time, and listed sequence, and determine if the codes are related to
the reported problem. Begin fault isolation with the most recent event code with the
highest severity level. Other codes may accompany this event code, or may indicate a
normal indication after a problem is recovered.
1. At the View panel, choose the Monitor option at the left side of the panel.
The Monitor panel opens with the Port List panel displayed.
2. At the Monitor panel, click the Log tab. The Monitor Log panel displays, as
shown in
3. Record the event code, date, time, and severity (Informational, Minor,
Major, or Severe).
4. Record all event codes that may relate to the reported problem.