Step Points
Function Group
Menu Map
Description
Programming Codes
See Also
FREQUENCY
2
This
lets you define the number of step points in a stepped
frequency sweep. The number of points in a stepped sweep can
range from 2 to 801. Step Size and Step Points are dependent
variables. If you know how many steps are desired in a given sweep,
use the
Step Points to set the desired value The step size
will be calculated automatically.
SCPI:
SWEep[:FREQ uency]:POINts
Analyzer:
NONE
Step Size, Step Swp Menu, Sweep Mode Step
“Using Step Sweep” in Chapter 1
Step Size
Function Group
Menu Map
Description
Programming Codes
See Also
FREQUENCY
2
This
lets you specify the step size in a stepped frequency
sweep. The range of increment size is dependent on frequency
span and the number of step points desired, as given by the
formula: STEP SIZE = SPAN STEP POINTS. Step Size and
Step Points are dependent variables, as shown by the formula. If
a particular step size is desired, use the Step Size
to set
the desired increment. The number of step points is then calculated
automatically.
SCPI:
SWEep[:FREQ uency]:STEP <num>[freq suffix] or
Analyzer:
NONE
Step Points, Step
Menu, Sweep Mode Step
“Using Step Sweep” in Chapter 1
S-60 Operating and Programming Reference