Coupling Factor
Function Group
ALC
M e n u M a p
Description
This
allows specification of the coupling factor of an external
coupler/detector used to externally level the swept CW generator
output power. Negative coupling factor values are required for valid
entry. See “Specifications” for the coupling factor range.
Programming Codes
SCPI:
POWer:ALC:CFACtor
Analyzer:
NONE
S e e A l s o
“Externally Leveling the Swept CW Generator” in Chapter 1
Function Group
FREQUENCY
M e n u M a p
Description
This
lets you select a synthesized continuous wave frequency.
When you press
the swept CW generator stops sweeping
(green SWEEP LED off) and displays:
CW:
XXXXX MHz
where
XXXXX represents a frequency value. Use either the rotary knob,
the step keys (with or without the left/right arrow keys), or the
numerical entry keys with a terminator key to set the desired value.
If a small change is desired, use the left and right arrow keys to
underline the digit to be changed.
Programming Codes
FREQuency[:CW] <num>[freq suffix] or
FREQuency:MODE CW
Analyzer: C
W
See Also
Coupled, (START), (STOP)
“CW Operation and Start/Stop Frequency Sweep” in Chapter 1
“Programming Typical Measurements” in Chapter 1
C-12 Operating and Programming Reference