Fabric OS Administrator’s Guide
503
53-1002745-02
End-to-end performance monitoring
20
This monitor (Monitor 1) counts the frames that have an SID of 0x011200 and a DID of 0x021e00.
For Monitor 1, RX_COUNT is the number of words from Host A to Dev B, and TX_COUNT is the
number of words from Dev B to Host A.
Example of monitoring the traffic from Dev B to Host A
On Domain 2, add a monitor to the F_Port as follows:
switch:admin>
perfaddeemonitor 2/14 "0x021e00" "0x011200"
This monitor (Monitor 4) counts the frames that have an SID of 0x021e00 and a DID of 0x011200.
For Monitor 4, RX_COUNT is the number of words from Dev B to Host A, and TX_COUNT is the
number of words from Host A to Dev B.
The E_Port monitors are configured similar to the F_Port monitors, but the ingress and egress
directions are reversed.
For Monitor 2:
switch:admin>
perfaddeemonitor 2/3 "0x021e00" "0x011200"
For Monitor 3:
switch:admin>
perfaddeemonitor 2/13 "0x011200" "0x021e00"
Setting a mask for an EE monitor
End-to-end monitors count the number of words in Fibre Channel frames that match a specific SID
and DID pair. If you want to match only part of the SID or DID, you can set a mask on the port to
compare only certain parts of the SID or DID. By default, the frame must match the entire SID and
DID to trigger the monitor. By setting a mask, you can choose to have the frame match only one or
two of the three fields (domain ID, area ID, and AL_PA) to trigger the monitor.
You specify the masks in the form
dd:aa:pp
, where
dd
is the domain ID mask,
aa
is the area ID
mask, and
pp
is the AL_PA mask. The values for
dd
,
aa
, and
pp
are either ff (the field must match)
or 00 (the field is ignored). The default EE mask value is ff:ff:ff.
NOTE
Only one mask per port can be set. When you set a mask, all existing end-to-end monitors are
deleted.
ATTENTION
End-to-end masks are supported only on the Brocade 8000 and the Brocade Encryption Switch.
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the perfSetPortEEMask command.
perfsetporteemask [
slotnumber
/]
portnumber
"
TxSIDMsk
" "
TxDIDMsk
" "
RxSIDMsk
"
"
RxDIDMsk
"
The perfSetPortEEMask command sets the mask for all end-to-end monitors of a port. If any
end-to-end monitors are programmed on a port when the perfSetPortEEMask command is issued,
then a message displays similar to the following example:
switch:admin>
perfsetporteemask 1/2, "00:ff:ff"
Changing EE mask for this port will cause ALL EE monitors on this port to be
deleted.
Continue? (yes, y, no, n): [no]
y
The EE mask on port 2 is set and EE monitors on this port are deleted
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...