568
Fabric OS Administrator’s Guide
53-1002745-02
Forward error correction on long-distance links
23
The following example enables buffer credit recovery on port 1/20.
switch:admin>
portcfgcreditrecovery 1/20 -enable
Forward error correction on long-distance links
Forward error correction (FEC) on user ports is supported for LD and LS long-distance modes. Use
the portCfgLongDistance command with the -fecEnable or -fecDisable options to enable or disable
FEC, respectively, on a user port. Alternatively, you can use the portCfgFec command with the
--
enable or
--
disable option as you would for any regular port.
For additional details about FEC, refer to
“Enabling forward error correction (FEC)”
on page 128.
Enabling FEC on a long-distance link
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the portCfgLongDistance command and include the -fecEnable option, or issue the
portCfgFec command with the
--
enable option.
3. Enter the portCfgFec
--
show command to verify the configuration.
Example
switch:admin>
portcfglongdistance 1/20 LS 1 -distance 122 –fecenable
FEC has been enabled.
Reserved Buffers = 982
Warning: port (132) may be reserving more credits depending on port speed.
switch:admin>
portcfgfec --show 1/20
Forward Error Correction capable: YES
Forward Error Correction configured: ON
Disabling FEC on a long-distance link
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the portCfgLongDistance command and include the -fecDisable option, or issue the
portCfgFec command with the
--
disable option.
3. Enter the portCfgFec
--
show command to verify the configuration.
Example
switch:admin>
portcfglongdistance 1/20 LS 1 -buffers 500 –fecdisable
FEC has been disabled.
Reserved Buffers = 982
Warning: port (132) may be reserving more credits depending on port speed.
switch:admin>
portcfgfec --show 1/20
Forward Error Correction capable: YES
Forward Error Correction configured: OFF
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...