![HP Fabric OS 7.1.0 Administrator'S Manual Download Page 508](http://html.mh-extra.com/html/hp/fabric-os-7-1-0/fabric-os-7-1-0_administrators-manual_165055508.webp)
508
Fabric OS Administrator’s Guide
53-1002745-02
Frame monitoring
20
Adding frame monitors to a port
If the switch does not have enough resources to add a frame monitor to a port, then other frame
monitors on that port may have to be deleted to free resources.
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the fmMonitor
--addmonitor command to add a frame monitor to one or more ports.
The set of ports to be removed from monitoring is automatically saved to the persistent
configuration unless you specify the -nosave option on the command.
Example
The following example adds a standard SCSI frame type monitor to ports 3 through 12.
switch:admin>
fmmonitor --addmonitor SCSI -port 3-12
Removing frame monitors from a port
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the fmMonitor
--
delmonitor command to remove a specific monitor from one or more
ports.
The set of ports to be removed from monitoring is automatically saved to the persistent
configuration unless you specify the -nosave option on the command.
Example
The following example removes the user-defined frame monitor, myframemonitor, from all ports.
switch:admin>
fmmonitor --delmonitor myframemonitor
Saving a frame monitor configuration
When you assign or remove frame monitors on ports, the list of ports to be monitored is
automatically saved persistently, unless you specified the
-
nosave option.
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the fmMonitor
--
save command to save the set of ports on which the frame type is
monitored to the persistent configuration.
Example
In the following example, the first command adds a standard SCSI frame type monitor to ports 3
through 12, but does not save the port configuration. The second command saves the port
configuration persistently.
switch:admin>
fmmonitor --addmonitor SCSI -port 3-12 -nosave
switch:admin>
fmmonitor --save SCSI
Displaying frame monitors
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the fmMonitor
--
show command.
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...