Fabric OS Administrator’s Guide
589
53-1002745-02
EX_Port frame trunking configuration
24
------------------------
7/3 1000
7/4 1000
7/9 1000
7/10 1000
7/13 1000
10/0 1000
You can also use the fcrRouteShow command to display the router port cost.
To display the router port cost for a single EX_Port, enter the fcrRouterPortCost command with
a port and slot number.
switch:admin>
fcrrouterportcost 7/10
Port Cost
------------------------
7/10
1000
4. Enter the appropriate form of the fcrRouterPortCost command based on the task you want to
perform:
•
To set the router port cost for a single EX_Port, enter the command with a port and slot
number and a specific cost:
switch:admin>
fcrrouterportcost 7/10 10000
•
To set the cost of the EX_Port back to the default, enter a cost value of 0:
switch:admin>
fcrrouterportcost 7/10 0
5. Enter the portEnable command to enable the ports that you disabled in
step 1
.
switch:admin>
portenable 7/10
EX_Port frame trunking configuration
You can configure EX_Ports to use frame-based trunking just as you do regular E_Ports. EX_Port
frame trunking support is designed to provide the best utilization and balance of frames
transmitted on each link between the FC router and the edge fabric. You should trunk all ports
connected to the same edge fabrics.
The FC router front domain has a higher node WWN—derived from the FC router—than that of the
edge fabric. Therefore, the FC router front domain initiates the trunking protocol on the EX_Port.
After initiation, the first port from the trunk group that comes online is designated as the master
port. The other ports that come online on the trunk group are considered the slave ports. Adding or
removing a slave port does not cause frame drop; however, removing a slave port causes the loss
of frames in transit.
The restrictions for EX_Port frame trunking are the same as for E_Ports—all the ports must be
adjacent to each other using the clearly marked groups on the front of the product.
ATTENTION
This feature should be enabled only if the entire configuration is running Fabric OS v5.2.0 or later.
If router port cost is used with EX_Port trunking, the master port and slave ports share the router
port cost of the master port.
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...