562
Fabric OS Administrator’s Guide
53-1002745-02
Buffer credit management
23
To determine the number of buffers required, perform the following steps:
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the portBufferCalc command and provide values for the distance, port speed, and frame
size.
Example
The following example calculates the number of buffers required for an 8-Gbps port on a 100-km
link with an average frame size of 512 bytes.
switch:admin>
portbuffercalc 9/4 -distance 100 -speed 8 -framesize 512
1606 buffers required for 100km at 8G and framesize of 512 bytes
Allocating buffer credits for F_Ports
The default configured F_Port buffer credit is fixed at eight buffers. You can use the
portCfgFPortBuffers command to configure a given port with the specified number of buffers. Note
that in the sample commands provided in the following procedure, 12 buffers are configured for an
F_Port.
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the portCfgFPortBuffers command.
switch:admin>
portcfgfportbuffers --enable 2/44 12
3. To disable the port buffer configuration and return to the default buffer allocation, use the
--
disable option
switch:admin>
portcfgfportbuffers --disable 2/44
NOTE
The configured number of buffers for a given port is stored in the configuration database and is
persistent across reboots. The F_Port buffer feature does not support EX_Port, Port Mirroring,
Long-Distance, L_Port, FastWrite, QoS, and Trunk Area enabled ports.
Monitoring buffers in a port group
Use the portBufferShow command to monitor the remaining buffers on a long-distance link and to
monitor the average frame size and average buffer usage for a given port.
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the portBufferShow command.
The average frame size in bytes is shown in parentheses with the average buffer usage for
packet transmission and reception.
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...