Testing and restoring firmware on Backbones
9
Testing and restoring firmware on Backbones
This procedure enables you to perform a firmware download on each CP and verify that the
procedure was successful before committing to the new firmware. The old firmware is saved in the
secondary partition of each CP until you enter the firmwareCommit command. If you decide to back
out of the installation prior to the firmware commit, you can enter the firmwareRestore command to
restore the former active Fabric OS firmware image.
The firmwareRestore command can only run if autocommit was disabled during the firmware
download. This command cannot be used to restore SAS and SA images.
NOTE
Brocade recommends that, under normal operating conditions, you maintain the same firmware
version on both CPs, and on both partitions of each CP. This organization enables you to evaluate
firmware before you commit. As a standard practice, do not run mixed firmware levels on CPs.
Testing different firmware versions on Backbones
1. Connect to the Brocade Backbone IP address.
2. Enter the ipAddrShow command and note the address of CP0 and CP1.
3. Enter the haShow command and note which CP is active and which CP is standby. Verify that
both CPs are in sync.
4. Enter the firmwareShow command and confirm that the current firmware on both partitions on
both CPs is listed as expected.
5. Exit the session.
6. Update the firmware on the standby CP.
a. Connect to the Backbone and log in as admin to the standby CP.
b. Enter the firmwareDownload -s command and respond to the prompts.
At this point, the firmware downloads to the standby CP only. When it has completed the
download to that CP, reboot it. The current Backbone session is disconnected.
7. Fail over to the standby CP.
a. Connect to the Backbone on the active CP.
b. Enter the haShow command to verify that HA synchronization is complete. It takes a
minute or two for the standby CP to reboot and synchronize with the active CP.
c. Enter the firmwareShow command to confirm that the primary partition of the standby CP
contains the new firmware.
d. Enter the haFailover command. The active CP reboots and the current Backbone session
is disconnected.
If an AP blade is present: At the point of the failover, an
autoleveling
process is activated.
Refer to
“Backbone firmware download process overview”
on page 262 for details about
autoleveling.
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...