![HP Fabric OS 7.1.0 Administrator'S Manual Download Page 383](http://html.mh-extra.com/html/hp/fabric-os-7-1-0/fabric-os-7-1-0_administrators-manual_165055383.webp)
Fabric OS Administrator’s Guide
383
53-1002745-02
Setting bottleneck detection alerts
13
FIGURE 48
Affected seconds for bottleneck detection
The -time parameter specifies the time window. For this example, -time equals 12 seconds.
The -cthresh and -lthresh parameters specify the thresholds on number of affected seconds that
trigger alerts for congestion and latency bottlenecks, respectively. This example uses the default
values for these parameters, where -cthresh = 0.8 (80%) and -lthresh = 0.1 (10%).
For this time window, 50% of the seconds (6 out of 12 seconds) are affected by congestion. This is
below the threshold of 80%, so an alert would not be generated for a congestion bottleneck.
For the same time window, 25% of the seconds (3 out of 12 seconds) are affected by latency.
This exceeds the threshold of 10%, so an alert would be generated for a latency bottleneck.
Setting both a congestion alert and a latency alert
Entering the bottleneckmon --enable -alert command enables both alerts using the default alert
values.
Example of setting an alert for both congestion and latency
This example enables both alerts and shows their values.
switch:admin>
bottleneckmon --enable -alert
switch:admin>
bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold - 0.800
Severity threshold - 50.000
Switch-wide alerting parameters:
================================
Alerts - Yes
Latency threshold for alert - 0.100
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...