514
Fabric OS Administrator’s Guide
53-1002745-02
Top Talker monitors
20
The output is sorted based on the data rate of each flow. If you do not specify the number of
flows to display, then the command displays the top 8 flows or the total number of flows,
whichever is less.
The following example displays the top 5 flows on port 7 in WWN (default) format:
perfttmon --show 7 5
The following example displays the top flows on slot 2, port 4 on a Backbone in PID format:
perfttmon --show 2/4 pid
switch:admin>
perfttmon --show 2/4 pid
========================================
Src_PID
Dst_PID
MB/sec
========================================
0xa90800
0xa05200
6.926
0xa90800
0xa908ef
6.872
Displaying top talking flows for a given domain ID (fabric mode)
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the perfTTmon
--
show dom command.
perfttmon --show dom
domainid
[
n
] [wwn | pid]
Fabric mode must be enabled for this option.
The output is sorted based on the data rate of each flow. If you do not specify the number of
flows to display, then the command displays the top 8 flows or the total number of flows,
whichever is less. The command can display a maximum of 32 flows.
The following example display the top 5 flows on for domain 1 in WWN (default) format:
perfttmon --show dom 1 5
The following example display the top flows on domain 2 in PID format:
switch:admin>
perfttmon --show dom 2 pid
=================================================================
Src_PID Dst_PID MB/sec Potential E-Ports
=================================================================
0x03f600 0x011300 121.748 2/0,2/2,2/3
0x03f600 0x011300 121.748 3/14,3/15
Deleting a Top Talker monitor on a port (port mode)
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the perfTTmon
--
delete command.
perfttmon --delete [
slotnumber
/]
port
The following example deletes the monitor on port 7:
perfttmon --delete 7
The following example deletes the monitor on slot 2, port 4 on a Backbone:
perfttmon --delete 2/4
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...