Fabric OS Administrator’s Guide
603
53-1002745-02
Proxy PID configuration
24
Proxy PID configuration
When an FC router is first configured, the PIDs for the proxy devices are automatically assigned.
Proxy PIDs (as well as phantom domain IDs) persist across reboots.
The most common situation in which you would set a proxy PID is when you replace a switch. If you
replace the switch and want to continue using the old PID assignments, you can configure it to do
so; this value remains in the system even if the blade is replaced. To minimize disruption to the
edge fabrics, set the proxy PIDs to the same values used with the old hardware.
The fcrProxyConfig command displays or sets the persistent configuration of proxy devices. Used
with the -s
slot
option, it can also influence the assignment of the xlate domain port number (which
is used to determine the Area_ID field of the PID) and the Port_ID field. Like the PIDs in a fabric, a
proxy PID must be unique. If the
slot
argument results in a duplicate PID, it will be ignored. Proxy
PIDs are automatically assigned to devices imported into a fabric, starting at f001. For Proxy IDs
projected to an M-EOS edge fabric in McDATA fabric mode, use valid ALPAs (lower 8 bits).
Use the fcrXlateConfig command to display or assign a preferred domain ID to a translate domain.
Fabric parameter considerations
By default, EX_Ports and VEX_Ports detect, autonegotiate, and configure the fabric parameters
without user intervention.
You can optionally configure these parameters manually.
•
To change the fabric parameters on a switch in the edge fabric, use the configure command.
Note that to access all of the fabric parameters controlled by this command, you must disable
the switch using the switchDisable command. If executed on an enabled switch, only a subset
of attributes is configurable.
•
To change the fabric parameters of an EX_Port on the FC router, use the portCfgEXPort
command.
•
To change the fabric parameters of a VEX_Port, use the portCfgVEXPort command.
The backbone fabric PID mode and the edge fabric PID mode do not need to match, but the PID
mode for the EX_Port or VEX_Port and the edge fabric to which it is attached must match. You can
statically set the PID mode for the fabric by using the -p option with the portCfgEXPort command.
Use the -t option to disable the negotiate fabric parameter feature; otherwise, the PID mode is
autonegotiated. The various edge fabrics may have different PID modes.
Fabric parameter settings, namely, E_D_TOV (error-detect timeout value), R_A_TOV
(resource-allocation timeout value), and PID format, must be the same on EX_Ports or VEX_Ports
and on the fabrics to which they are connected. You can set the PID format on an EX_Port when you
configure an inter-fabric link.
The default values for E_D_TOV and R_A_TOV for an EX_Port or VEX_Port must match those values
on other Fabric OS switches. You do not need to adjust these parameters for an EX_Port or
VEX_Port unless you have adjusted them for the edge fabric.
The default values for R_A_TOV and E_D_TOV are the recommended values for all but very large
fabrics (ones requiring four or more hops) or high-latency fabrics (such as ones using long-distance
FCIP links).
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...