![HP Fabric OS 7.1.0 Administrator'S Manual Download Page 190](http://html.mh-extra.com/html/hp/fabric-os-7-1-0/fabric-os-7-1-0_administrators-manual_165055190.webp)
190
Fabric OS Administrator’s Guide
53-1002745-02
Telnet protocol
6
SNMP security levels
Use the snmpConfig
--
set seclevel command to set the security level. For more information about
using the Brocade SNMP agent, refer to the
Fabric OS MIB Reference
.
SNMP configuration
Use the snmpConfig
--
set command to change either the SNMPv3 or SNMPv1 configuration. You
can also change access control, MIB capability, and system group.
For details on Brocade MIB files, naming conventions, loading instructions, and information about
using the Brocade SNMP agent, refer to the
Fabric OS MIB Reference
.
Telnet protocol
Telnet is enabled by default. To prevent passing clear text passwords over the network when
connecting to the switch, you can block the Telnet protocol using an IP filter policy. For more
information on IP filter policies, refer to
“IP Filter policy”
on page 217.
ATTENTION
Before blocking Telnet, make sure you have an alternate method of establishing a connection with
the switch.
Blocking Telnet
If you create a new policy using commands with just one rule, all the missing rules have an implicit
deny and you lose all IP access to the switch, including Telnet, SSH, and management ports.
Use the following procedure to block Telnet access.
1. Connect to the switch and log in using an account with admin permissions.
2. Clone the default policy by typing the ipFilter
--
clone command.
switch:admin>
ipfilter --clone BlockTelnet -from default_ipv4
3. Save the new policy by typing the ipFilter
--
save command.
switch:admin>
ipfilter --save BlockTelnet
4. Verify the new policy exists by typing the ipFilter
--
show command.
switch:admin>
ipfilter --show
5. Add a rule to the policy, by typing the ipFilter
--
addrule
command.
switch:admin>
ipfilter --addrule BlockTelnet -rule 1 -sip any -dp 23 -proto
tcp -act deny
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...