![HP Fabric OS 7.1.0 Administrator'S Manual Download Page 564](http://html.mh-extra.com/html/hp/fabric-os-7-1-0/fabric-os-7-1-0_administrators-manual_165055564.webp)
564
Fabric OS Administrator’s Guide
53-1002745-02
Buffer credit management
23
For the FC8-x port blades, the first number in the Unreserved buffer credits column designates the
number of unreserved buffers per port group without buffer optimized mode; the second number
designates the unreserved buffers with buffer optimized mode enabled on the slot. Use the
bufOpMode command to display or change the buffer optimized mode.
Maximum configurable distances for Extended Fabrics
Table 84
shows the maximum supported extended distances (in kilometers) that can be configured
for one port on a specific switch or blade at different speeds.
FC8-32
32
16
1292/508
FC8-32E
32
16
5456
FC8-48
48
24
1228/716
FC8-48E
48
24
5008
FC8-64
*** Extended Fabrics is not supported on this blade ***
FC16-32
32
16
5456
FC16-48
48
24
5008
FS8-18
16
8
1604
FX8-24
12
12
1060
TABLE 84
Configurable distances for Extended Fabrics
Maximum distances (km) that can be configured (assuming a 2112-byte frame size)
Switch/blade model
2 Gbps
4 Gbps
8 Gbps
10 Gbps
16 Gbps
300
486
243
121
N/A
N/A
5100
1694
847
423
N/A
N/A
5300
294
147
73
N/A
N/A
5410
582
291
145.5
N/A
N/A
5424
486
243
121.5
N/A
N/A
5450
470
235
117.5
N/A
N/A
5480
486
243
121.5
N/A
N/A
6505
7426
3713
1856
1485
928
6510
6754
3377
1688
1350
844
6520
4064
2032
1016
812
508
7800
410
205
102
N/A
N/A
8000
*** Extended Fabrics is not supported on this switch ***
VA-40FC
1694
847
423
N/A
N/A
Brocade Encryption Switch
1392
696
348
N/A
N/A
FC8-16
1294
647
323
N/A
N/A
TABLE 83
Total FC ports, ports per port group, and unreserved buffer credits per port group
Switch/blade model
Total FC ports (per switch/blade) User port group size Unreserved buffer credits per port
group
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...