![HP Fabric OS 7.1.0 Administrator'S Manual Download Page 509](http://html.mh-extra.com/html/hp/fabric-os-7-1-0/fabric-os-7-1-0_administrators-manual_165055509.webp)
Fabric OS Administrator’s Guide
509
53-1002745-02
Frame monitoring
20
Example
The following example displays the existing frame types and associated bit patterns on the switch.
switch:admin>
fmmonitor --show
FRAME_TYPE
BIT
PATTERN
----------------------------------------
scsi
12,0xFF,0x08;
scsiread
12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x08,0x28;
scsiwrite
12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x08,0x28,0x0A,0x2A;
scsirw
12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x08,0x28,0x0A,0x2A;
scsi2reserve
12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x16,0x56;
scsi3reserve
12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x5F;41,0xFF,0x01
ip
12,0xFF,0x05;
abts
4,0xFF,0x81;40,0xFF,0x81;12,0xFF,0x0;17,0xFF,0x0;
baacc
4,0xff,0x84;12,0xff,0x00;17,0xff,00;
The following example displays configuration details for the predefined SCSI frame monitor. Notice
that in the last entry, the “-” in the Count column indicates that the monitor is configured, but is not
installed on the port.
switch:admin>
fmmonitor --show SCSI
Port|Frame Type |Count
|HIGH Thres|Actions
|TIMEBASE
|CFG
-----------------------------------------------------------------------------
000001|scsi
|0x0000000000000123|1000
|None
|saved
000002|scsi
|0x0000000000000125|1000
|None
|saved
000003|scsi
|0x0000000000000143|1000
|None
|saved
000022|scsi
|-
|0
|None
|None
|saved
The following example displays values for the predefined SCSI frame monitor on port 5, every 5
seconds.
switch:admin>
fmmonitor --show scsi -port 5 -timeinterval 5
Port|Count
|
----------------------
2011-03-21 00:59:50
000005|
48.3k
2011-03-21 00:59:55
000005|
48.6k
(output truncated)
Clearing frame monitor counters
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the fmMonitor
--
clear command to clear the counters on the ports on which the
specified frame type is monitored.
Example
The following example clears the counters for the ABTS monitor from ports 7 through 10.
switch:admin>
fmmonitor --clear ABTS -port 7-10
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...