Fabric OS Administrator’s Guide
599
53-1002745-02
LSAN zone configuration
24
With LSAN zone binding, each FC router in the backbone fabric stores only the LSAN zone entries of
the remote edge fabrics that can access its local edge fabrics. The LSAN zone limit supported in
the backbone fabric is not limited by the capability of one FC router. In addition, due to the lower
LSAN count, the CPU consumption by the FC router is lower. If you configure the metaSAN such that
the backbone fabric has two groups of FC routers and there is no LSAN zone sharing and device
access between the two groups, the number of FC routers and devices supported in the backbone
fabric can be higher.
Figure 81
on page 599 shows a sample metaSAN with four FC routers in the backbone fabric.
Without LSAN zone binding, each FC router in the backbone fabric would store information about
LSAN zones 1, 2, 3, and 4.
FIGURE 81
LSAN zone binding
After you set up LSAN zone binding, each FC router stores information about only those LSAN zones
that access its local edge fabrics.
Table 85
shows what LSAN information is stored in each FC
router before and after LSAN zone binding is in effect.
LSAN zone 1
Backbone fabric
LSAN zone 2
LSAN zone 3
LSAN zone 4
Fabric 1
Fabric 2
Fabric 3
Fabric 4
Fabric 5
Fabric 6
FC
router 1
FC
router 3
Fabric 7
FC
router 4
Fabric 9
FC
router 2
Fabric 8
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...