Fabric OS Administrator’s Guide
393
53-1002745-02
Chapter
14
In-flight Encryption and Compression
In this chapter
•
In-flight encryption and compression overview . . . . . . . . . . . . . . . . . . . . . . 393
•
Configuring encryption and compression . . . . . . . . . . . . . . . . . . . . . . . . . . 399
•
Encryption and compression examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
•
Working with EX_Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
In-flight encryption and compression overview
The in-flight encryption and compression features of Fabric OS allow frames to be encrypted or
compressed at the egress point of an ISL between two Brocade switches, and then to be decrypted
or decompressed at the ingress point of the ISL. These features use port-based encryption and
compression. You can enable the encryption and compression feature for both E_Ports and
EX_Ports on a per-port basis. By default this feature is initially disabled for all ports on a switch.
NOTE
The in-flight encryption and compression features are supported for any port speed, but only on
16G-capable E_Ports and EX_Ports on the Brocade 6510 and 6520 switches and the Brocade DCX
8510 Backbone family.
The purpose of encryption is to provide security for frames while they are in flight between two
switches. The purpose of compression is for better bandwidth use on the ISLs, especially over long
distance. An average compression ratio of 2:1 is provided. Frames are never left in an encrypted or
compressed state when delivered to an end device. Both ends of the ISL must terminate in
16G-capable FC ports.
Encryption and compression can be enabled at the same time for an ISL, or you can enable either
encryption or compression selectively.
Figure 49
shows an example of 16 Gbps links connecting
three Brocade switches. One link is configured with encryption and compression, one with just
encryption, and one with just compression.
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...