Fabric OS Administrator’s Guide
505
53-1002745-02
Frame monitoring
20
perfmonitorshow --class
monitor_class
[
slotnumber
/]
portnumber
[
interval
]
Example of displaying an end-to-end monitor on a port at 10-second intervals
switch:admin>
perfMonitorShow --class EE 4/5 10
Showing EE monitors 4/5 10: Tx/Rx are # of bytes
0
1
2
3
4
---------
---------
---------
---------
---------
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
=========
=========
=========
=========
=========
0
0
0
0
0
0
0
0
0
0
53m
4.9m
53m
4.9m
53m
4.9m
53m
4.9m
53m 0
53m
4.4m
53m
4.4m
53m
4.4m
53m
4.4m
53m 0
53m
4.8m
53m
4.8m
53m
4.8m
53m
4.8m
53m 0
53m
4.6m
53m
4.6m
53m
4.6m
53m
4.6m
53m 0
53m
5.0m
53m
5.0m
53m
5.0m
53m
5.0m
53m 0
53m
4.5m
53m
4.5m
53m
4.5m
53m
4.5m
53m 0
Example of displaying EE monitors on a port
switch:admin>
perfMonitorShow --class EE 4/5
There are 7 end-to-end monitor(s) defined on port 53.
KEY SID DID OWNER_APP TX_COUNT
RX_COUNT
OWNER_IP_ADDR
------------------------------------------------------------------------------------------
0 0x58e0f 0x1182ef TELNET
0x0000000000000000 0x0000000000000000
N/A
0 0x21300 0x21dda TELNET
0x00000004d0ba9915 0x0000000067229e65
N/A
1 0x21300 0x21ddc TELNET
0x00000004d0baa754 0x0000000067229e65
N/A
2 0x21300 0x21de0 TELNET
0x00000004d0bab3a5 0x0000000067229e87
N/A
3 0x21300 0x21de1 TELNET
0x00000004d0bac1e4 0x0000000067229e87
N/A
4 0x21300 0x21de2 TELNET
0x00000004d0bad086 0x0000000067229e87
N/A
5 0x11000 0x21fd6
WEB_TOOLS 0x00000004d0bade54 0x0000000067229e87 192.168.169.40
6 0x11000 0x21fe0
WEB_TOOLS 0x00000004d0baed41 0x0000000067229e98 192.168.169.40
Clearing EE monitor counters
The following example clears statistics counters for an end-to-end monitor:
switch:admin>
perfMonitorClear --class EE 1/2 5
End-to-End monitor number 5 counters are cleared
The following example clears statistics counters for all end-to-end monitors on a specific port:
switch:admin>
perfMonitorClear --class EE 1/2
This will clear ALL EE monitors' counters on port 2, continue?
(yes, y, no, n): [no]
y
Frame monitoring
Frame monitoring counts the number of times a frame with a particular pattern is transmitted by a
port, and generates alerts when thresholds are crossed. Frame monitoring is achieved by defining
a filter, or frame type, for a particular purpose. The frame type can be a standard type (for example,
an SCSI read command filter that counts the number of SCSI read commands that have been
transmitted by the port) or a user-defined frame type customized for your particular use. For a
complete list of the standard, predefined frame types, refer to the fmMonitor command description
in the
Fabric OS Command Reference
.
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...