458
Fabric OS Administrator’s Guide
53-1002745-02
SAN management with Admin Domains
17
Admin Domains, zones, and zone databases
Admin Domains introduce two types of zone database nomenclature and behavior:
•
Root zone database
If you do not use Admin Domains, there is only one zone database. This legacy zone database
is known as the
root zone database
. If you create Admin Domains, several zone databases
exist: the root zone database, which is owned by AD0, and other zone databases, one for each
user-defined Admin Domain.
AD-level zone information is merged with the root zone configuration and enforced.
•
AD zone databases
Each AD (AD1 through AD254) has its own zone database, with the defined and effective zone
configurations and all related zone objects (zones, zone aliases, and zone members). Each AD
has its own zone transaction buffer. Within an Admin Domain, you can configure zoning only
with the devices that are present in that Admin Domain.
FDMI
FDMI operations are allowed only in AD0 and AD255.
FICON
Admin Domains support FICON. However, you must perform additional steps because
FICON management requires additional physical control of the ports. You must set up the
switch as a physical member of the FICON AD.
Device Connection Control (DCC) and Switch Connection Control (SCC) policies are
supported only in AD0 and AD255, because ACL configurations are supported only in
AD0 and AD255.
iSCSI
iSCSI operations are supported only in AD0.
LSAN zoning
Refer to
“Admin Domains and LSAN zones”
on page 459 for details.
Management
applications
Management interfaces that access the fabric without a user’s credentials continue to
get the physical fabric view. Examples include SNMPv1, Web Tools, HTTP access,
unzoned management server query, FAL in-band CT requests from FAL Proxy to FAL
Target, and FC-CT-based management applications.
Access from applications or hosts using management server calls can be controlled
using the management server ACL support provided by the msConfigure command. Note
that this is a switch-specific setting and not a fabric-wide setting.
Port swapping and PID
formats
Admin Domain port members are specified in
domain,index
format. Based on the PID
format, a
domain,index
member indicates a slot and port in the switch. The
domain,index
member is effectively a member of that AD.
Port swapping has no effect on AD support as port swapping swaps only the area
numbers of two ports and Admin Domains are specified using
domain,index
members.
For detailed information about configuring the PID format, refer to
Chapter 3,
“Performing Advanced Configuration Tasks”
.
RSCN
Admin Domains do not introduce any RSCN changes to devices or hosts.
Virtual Fabrics
Virtual Fabrics and Admin Domains are mutually exclusive and are not supported at the
same time on a switch. To use Admin Domains, you must first disable Virtual Fabrics; to
use Virtual Fabrics, you must first delete all Admin Domains.
If you connect a switch with Admin Domains to a Virtual Fabrics-enabled switch, the link
is segmented with the reason “VF AD conflict.”
Zoning
Refer to
“Admin Domains, zones, and zone databases”
on page 458 for details.
TABLE 67
Admin Domain interaction with Fabric OS features (Continued)
Fabric OS feature
Admin Domain interaction
Summary of Contents for Fabric OS 7.1.0
Page 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Page 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Page 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Page 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Page 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Page 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Page 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Page 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Page 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Page 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Page 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Page 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Page 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Page 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...