MAIN PARTS
3.1.2.
SPECIFICATIONS OF INVERTER
Applicable Models
RAS-5FSG, RAS-5FS3, RAS-8FSG, RAS-8FS3, RAS-10FSG, RAS-10FS3, RAS-
16FSG, RAS-16FS3, RAS-20FSG, RAS-20FS3
Applicable Power Source
3 Phase 380 / 415V
10% 50Hz
5%
Output Voltage (Maximum)
380 / 415V, 3 Phase
Output Current (Maximum)
14.0A (5,8 and 10HP) / 16.5A (16 and 20HP)
Time Rating
Continuous
Control Method
Frequency
75Hz, Space Vector PWM Control 75Hz
<
Frequency
115Hz, V/F Control
Range Output Frequency
30~95Hz (5HP), 30~115Hz (8,10, 16 and 20HP)
Accuracy of Frequency
0.005Hz at Applicable Frequency Range
Controlled Frequency
0.01Hz
Accuracy of Output Voltage
±10% at Applicable Frequency Range
Output / Characteristics
Conditons:
1. Power Source Voltage AC380/415V
2. Non-Loading (Free Output)
3. Ammeter Type Volt-Meter (
3
1.1)
Refer to the follow note
Soft Start-Stop
0.5Hz/S, 1Hz/S, 3Hz/S, 6Hz/S, 30Hz/S (5 Steps)
Protection Function
Excessive High or Low Voltage
for Inverter
Excessive Low Voltage at a Voltage is lower than 350V
Excessive High Voltage at a Voltage is higher than 750V
Abnormality of Current Sensor
Stoppage at a current of compressor smaller than 0.5A
When the frequency is 15~18Hz after starting.
Cause of Abnormality: Failure of current Sensor
Failure of transistor module
Failure of compressor
Disconnected wiring
NOTE:
Characteristics are fluctuated by the current minimize control.
Summary of Contents for FS3 Series
Page 2: ......
Page 4: ......
Page 114: ......
Page 190: ......
Page 192: ...3 20 MAIN PARTS n Control board 1 PCB1 2 2 ...
Page 193: ...3 MAIN PARTS 21 n Fan Control Board PCB2 ...
Page 194: ...3 22 MAIN PARTS n Inverter Board PCB3 n Snubber Board PCB5 ...
Page 196: ...3 24 MAIN PARTS n Control Board PCB of Indoor Unit Only for RPK Model ...
Page 198: ...3 26 MAIN PARTS n PC 5H ...
Page 199: ...3 MAIN PARTS 27 3 11 CIRCUIT DIAGRAM FOR PRINTED CIRCUIT BOARD OF RECEIVER ...
Page 200: ......
Page 239: ......
Page 240: ...SMGB0001 06 01 Printed in Spain ...