______________________________________________
HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
127
GUI FAULT MATRIX WORKSHEET
SCREEN TITLE
FAULT NAME
FAULT NOTES
WARNING
DRIVE CHAIN
Exciter A
Summary Fault
Check exciter for more information
Exciter B
Summary Fault
Check exciter for more information
Active Exciter
Mute
Check exciter for more information
Unlock
Check exciter for more information
Exciter Power
Check exciter for more information
P.A. CABINET
Module Faults
Individual Module Faults
Check fault blink code on module
Cabinet Faults
Forward Power
Low RF power at the cabinet output
Y
Reflected Power
High reflected power at cabinet
Y
Drive Power
Abnormal drive power level
Y
Cooling
Cabinet Air
Check motor and air switch S2
Interlocks
Door
Check for door closure or discharge circuit
failure
External
Reject load thermal overtemperature switch
Power Supply
50V Power Supply 1
Check power supply card for fault display
50V Power Supply 2
Check power supply card for fault display
OUTPUT
System
Forward Power
Little or no output power
Y
VSWR Trip
Software set, High reflected power
VSWR Foldback
Software set, moderate reflected power
Y
Reject Loads
Reject 1
Reject load power exceeds load rating
Y
Reject 2
Reject load power exceeds load rating
Y
Reject 3
Reject load power exceeds load rating
Y
Mutes
RF Mute
Multiple causes
RF Switch 1 Mute
Interlocks of switch are not complete
RF Switch 2 Mute
Interlocks of switch are not complete
POWER SUPPLY
System
AC Low
Control system line voltage summary fault
Y
AC Phase Loss
Loss of phase sensor, low or missing phase
+ 5 Volt DC
Control system voltage monitoring
+ 12 Volt DC
Control system voltage monitoring
- 12 Volt DC
Control system voltage monitoring
+3.3 Volt DC
Control system voltage monitoring
AC Mains
A-B
Control system line voltage monitoring
B-C
Control system line voltage monitoring
C-A
Control system line voltage monitoring
SYSTEM
System Interlocks
External
External interlock to 1A7TB1 1-2
Failsafe
Failsafe interlock to 1A7TB1 3-4
Front Panel
No cable connection to J4 front panel