WARNING: Disconnect and lockout AC primary power prior to servicing
100
e.
Measure the transmitter sample at test point TX,and adjust SET pot for the
same or slightly less, voltage that the exciter sample.
NOTE:
It may be necessary to add or delete attenuation pad(s) in transmitter
sample line to obtain proper voltage.
f.
Reduce transmitter power to zero.
g.
Switch AGC MODE switch to ON.
h.
Increase exciter power until transmitter power is 100%.
i.
Adjust SET pot to reduce transmitter power to about 70% for room
temperatures near 70°F. If room temperature is near 110°F adjust to 95%, and if
near 50°F adjust for 65%.
j.
Increase exciter drive to 100% power.
When the room is cold, if there are problems with module overdrive faults when turning
the transmitter ON, adjust SET pot for less power reduction. If the transmitter sample
voltage is much less than the exciter sample, there may not be enough range for power
reduction adjustment.
NOTE:
If adjusting the visual AGC changed the drive level, check adjustment of the
exciter precorrection for differential gain, ICPM, and differential phase. Refer to
the exciter manual.