WARNING: Disconnect and lockout AC primary power prior to servicing
49
J34 OPTIONAL STATUS
1: EXCITER A SELECTED
2: EXCITER B SELECTED
3: MANUAL SELECTED
4: FUTURE OPTION
5: FUTURE OPTION
6: GROUND
7: GROUND
8: GROUND
9: VOLTAGE, This voltage follows the main status selection choice.
Optional Status Functions:
EXCITER A SELECTED: Indicates exciter "A" is selected.
EXCITER B SELECTED: Indicates exciter "B" is selected.
MANUAL SELECTED: Indicates the switcher is in the manual mode.
2.15 Transmitter Check Out
!
WARNING:
BEFORE PROCEEDING WITH CHECK OUT, INSPECT THE TRANSMITTER FOR AC
POWER SHORTS, LOOSE HARDWARE, WIRING ERRORS, UNCONNECTED WIRES,
MISSING PARTS, AND DEBRIS.
The following procedures are the sequential steps to safely turn on the transmitter for
the first time, and should be performed in the order listed. It is recommended that the
installation personnel read the general description in section one, the controls and
operation material in section three, and these procedures before starting.
2.15.1 Control Cabinet Pre-Operational Check Out
!
WARNING:
BEFORE APPLYING PRIMARY AC MAINS POWER FOR THE FIRST TIME, TURN OFF ALL
CIRCUIT BREAKERS THAT DISTRIBUTE POWER TO THE CONTROL AND PA CABINETS.
2.15.1.1 Three Phase AC and Logic Supply Checkout
STEP 1:
Open circuit breakers on the front panel.
STEP 2:
Apply 3 phase power to the control cabinet only.