WARNING: Disconnect and lockout AC primary power prior to servicing
85
STEP 33:
Set Fault Log Filters. Fault Log filters (new as of eCDi™ firmware
revision 3.0.L) provide a way to block or limit the entries in the Fault Log.
Figure 3-17 shows the choices for the 3 categories of filters:
a.
Faults
b.
Warnings
c.
Info
Figure 3-17 Fault Log Filters
•
Selecting “
None
” (no filter) will allow
all
indications for the selected
category to be entered into the Fault Log.
•
Selecting “
Sum
” will block all Summary indications in the selected
category. All other indications in that category will be entered into the
Fault Log.
•
Selecting “
All but Sum
” (the most common selection) will block all
entries but the Summary indications for the selected category (i.e. only
summary indications will be entered into the Fault Log).
•
Selecting “
All
” will block all Fault Log entries for that category. This
is most commonly used for the Info category since these are mostly
Status indications.
STEP 34:
When all changes are made, press Submit and then press Back to return to the
main menu. Click on Meter Logging to access the screen in Figure 3-18.