WARNING: Disconnect and lockout AC primary power prior to servicing
44
2.13.3 Individual PA Cabinet External Interlocks
DANGER:
THE THERMAL INTERLOCK SWITCHES ON HYBRID REJECT LOADS MUST
BE CONNECTED TO INTERLOCK OFF AFFECTED TRANSMITTER CABINETS
TO PREVENT OPERATOR EXPOSURE TO HOT OIL SPILLING FROM A
REJECT LOAD ABSORBING EXCESSIVE POWER.
Each PA cabinet has an interlock circuit that is used to turn off the appropriate PA
cabinets when a reject load thermal interlock opens. The electrical connections are
available by cutting the orange jumper between pins 4 and 5 of the cabinet control
cable. Normal connection is to turn off the cabinets that can furnish power to that reject
load. The two cabinet interlocks are connected in parallel then with the normally closed
interlock switch. Systems with more than two cabinets have the larger load connected to
the system interlock.
2.13.4 External Blower Control:
K2, part of the I/O panel contains 4 form C contacts, connect external blower contactors
or air conditioning controls as needed.
WARNING:
WIRING ABOVE 48 VOLTS MAY INTRODUCE A SAFETY HAZARD. 24 VOLT AC COIL
CONTACTORS ARE SUGGESTED.
They may be used for air system contactor control as desired. The contacts are rated 5
amps.
2.13.5 RF Samples
The metering RF samples are optimized for a voltage of 3 volts at the detector test points.
Levels higher than that will require adding attenuator pads for the proper levels.
The feedback samples for the digital exciters should be as follows:
Apex exciter, samples should be as close to minus five dBm as possible measured at the
exciter sample input. Attenuator pads are available in 1 dB steps to control the level.
CD1A level should be plus 5 dBm.
Special note to customers with both Apex and CD 1A exciters installed: Attenuate the
post mask filter sample only in the splitter output path connected to the Apex, not in the
path connected to the CD 1A. In this manner, the CD 1A level can be maintained at +5
dBm while the Apex sample level can be attenuated to -5dBm.