for data. In transmitters with only a single amplifier cabinet,
the monitor board only monitors one slave controller; it does so
continuously, and the LED should remain lighted continuously.
3.17.2.8 Cabinet ON Switch
This is a local ON switch for emergency and troubleshooting purposes. A local ON
command is not possible while the control cabinet main controller is in the OFF state and
sending this OFF command to the slave controller. Removing the cable at J-2 disables the
main controller’s authority over the slave controller, allowing independent control.
3.17.2.9 Cabinet ON LED
Indicates cabinet ON status.
3.17.2.10 Cabinet Off Switch
A local OFF switch for emergency use and troubleshooting. It will shut the cabinet down
only momentarily if the main controller is connected and in the ON state. Removing the
cable at J-2 gives the cabinet slave controller independent control, but external interlock
protection to the
cabinet is lost.
Figure 3-26. Slave Controller