______________________________________________
HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
188
Figure 8-6 Module Test Fixture
The Platinum TV Module Test Fixture consists of a table top assembly with a
interconnect cable ending in a plug assembly that is inserted into an empty module slot.
The cable to the test load is routed through the end cover opposite the fan and connected
inside the test fixture by reaching through the cooling slot.
An interlocked Safety Cover must be in place to activate RF drive to the module under
test.
Breaker CB1 limits the current to 50 amps, protecting the cable. Breaker CB2 at the test
fixture trips from excess module current and can be used as module power switch.
Interlock switch S2 and driver relay K1 prevent application of RF drive until the cover is
closed.
Fuse F1 provides protection for the small signal wiring in the extender and the 50 Volt
DC fan.