______________________________________________
HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
88
3.12 eCDi Software Updates
This section provides instructions necessary to install software updates on the eCDi™. The
procedure is very simple but could require 20 minutes or more to upload the new software
but only about 2 minutes to upgrade at which time the eCDi™ will be offline.
Please Read before updating Software
Please note that as of software revision 2.6.K (and higher) the fixed eCDi™
configuration port IP address has changed (the ethernet port on the front of the unit).
The old address was 192.168.0.254. The new Configuration port IP address as of
Revision 2.6.K is:
192.168.217.254 (subnet mask of 255.255.255.0)
If you are using DHCP on the remote computer which is connecting to the eCDi™
then no changes are required to connect. If you are using a fixed IP address to access
the eCDi™ then set the IP address of the remote computer to
192.168.217.1
.
For more information see "3.12 eCDi™ Configuration" on page 3-11.
Exciter 1:
192.168.217.200
Exciter 2:
192.168.217.201
3.12.1 Updating the eCDi™
If it is necessary to update the software in the eCDi™, the administrator login and
password are required.
3.12.1.1 Before Starting...
There are 2 versions of the "eCDi.bin" file used to upgrade the unit. One is about 3MB
and the other is about 30MB. It is recommended that the following steps be performed
first using the smaller eCDi.bin file and then again using the larger eCDi.bin file. The
smaller file updates the eCDi™ software, while the larger file updates the online
manual and the operating system packages.