HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
29
1.4.0.3 Percent of Power With Four PA Cabinets
CABINETS
A/B
CABINETS
C/D
AB/CD COMBINED
A & B REJECT C & D REJECT REJECT
OUTPUT
ONE
50 BOTH
0 25 225
BOTH
0 ONE
50 25 225
BOTH
0
NONE
0 100
100
ONE
50 ONE
50 0 100
BOTH
0
BOTH
0 0 400
This information can be used to calibrate the power metering for the cabinet and reject
loads. This is assuming the phase and gain controls have minimized the amount of
reject power and the cabinets output powers are about the same.
1.4.0.4 Drive Power Meter Calibration
The drive levels can be calibrated using the drive directional coupler element. The
Agilent power meter has a offset feature, enter the coupling ratio from the element as
the offset. The power meter now reads the power direct. This procedure can also be
used as an alternative to calibrate the cabinet power out and reject load power.