HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
119
•
Reject Load excess dissipation fault. Refer to drawing 801-0210-011 sheet 14
for Reject Load Test Points: TP 22, TP 23, TP 24. A typical input sample is
50 mW (100mW max) average, provides about 3.0 volts DC at the above test
points.
•
Mute status:
a.
System control mute
b.
Mute Fault due to operation of the RF coax switches. During operation of the
switches, drive will be muted. Should a switch fail to complete a transfer, the
drive will remain muted as controlled by the coax transfer switch interlock
system.
Figure
4-18
Output
Tab,
Meters Button
Readings of system output power, reflected power, and VSWR. There is additional power
metering for up to three reject loads. This metering is in percent of the reject load power
rating.