Chapter 3 Installation
47
SW+
Push Button Input
SW+
Push Button Input
SW-
GND
SW-
GND
The following electrical specifications apply to the internal or external power supply.
Terminal
Parameter Minimum
Format
Maximum
Unit
Internal 24V power supply
INT – ING
Voltage
23
24
25
V
Current
0
-
2
A
External 24V requirements
EXV – EXG
Voltage
20
24
29
V
Current
0
-
2
A
The digital I/O is manufactured by complying with the IEC 61131-2 standard. The
following electrical specifications apply.
Terminal
Parameter
Minimum
Format
Maximum
Unit
Digital output
FOx / DOx
Current
0
-
0.2
A
FOx / DOx
Voltage drop
0
-
0.5
V
FOx / DOx
Leakage current
0
-
0.1
mA
FOx / DOx
Functions
-
PNP
-
Format
FOx / DOx
IEC 61131-2
-
1A
-
Format