Chapter 9 Programming
147
Conveyor Start Options
If the I/O set in the trigger satisfies the condition, it starts tracking the conveyor.
Trigger
: Set the I/O and condition that trigger the start of conveyor tracking. Only Digital
Input is available.
Setting Conveyor Command
Set the actions to be executed during conveyor tracking.
During conveyor tracking, the robot moves to the Move position specified by the conveyor
moving direction. Only Linear Move can be set in the conveyor.
The real-time monitoring function of If and Loop can not be set for operation during
conveyor tracking.
Conveyor tracking is finished when all work in the conveyor tracking is complete.