Seite 1 von 2
Classification TITANUS
PRO·SENS
®
and PRO·SENS
®
2
With acceleration openings and without air filters
1)
Available for following pipe accessories:
DM-MB-TM-xx and/or VSK and/or MB2
3)
Available for following pipe accessories:
Detonation prevention device EG IIx and/or KA-DN 25
Detonation prevention device EG IIx and/or DM-MB-TM-xx and/or VSK and/or MB2
OXY·SENS
®
and/or VSK and/or DM-MB-TM-xx and/or KA-DN 25 and/or MB2
2)
Available for following pipe accessories:
OXY·SEN
S
®
VSK and/or DM-MB-TM-xx and/or KA-DN 25 and/or MB2
189
Number of aspiration
apertures
Module
Sensitivity
[% light
obs./ft]
27
28
30
31
32
33
34
36
37
40
41
44
45
51
52
53
56
57
60
63
64
65
72
80
100
DM
-TP
-
01
0,015
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
0,03
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
0,06
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
0,12
10
0,1
C
C
C
C
C
C
C
C
C
C
0,2
0,4
0,8
50
0,5
1
Number of aspiration
apertures
Pipe shape
Fan voltage
[V]
27
28
30
31
32
33
34
36
37
40
41
44
45
51
52
53
56
57
60
63
64
65
72
80
100
Without additional pipe accessories
P
e
r
m
i
t
t
e
d
t
o
t
a
l
p
i
p
e
l
e
n
g
t
h
[m
]
I
6,9
≥ 9
U
6,9
≥ 9
200 200 200 160 160 160 160 160 160 160
M
6,9
≥ 9
240 240 240 240 240 240 210 210 210 210 210 210 210 210 180 180 180 180 180 180
Double U
(1 DM)
6,9
9
300 300 300 300 300 220 220 220 220 220 220 220 220 220 220 220 220
12
300 300 300 300 300 300 300 300 300 300 300 300 260 260 260 260 260 260 260 260 260 250 250 250 250
Double U
(2 DM)
6,9
9
220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220
12
220 220 220 220 220 220 220 220 220 220 220 220 180 180 180 180 180 180 180 180 180 180 180
With detector box and VSK
1)
I
6,9
≥ 9
U
6,9
≥ 9
150 150 150 150 150 150 150 150
M
6,9
≥ 9
220 220 220 190 190 190 190 190 190 190 190 190 190 160 160 160 160 160
Double U
(1 DM)
6,9
9
270 270 200 200 200 200 200 200 200 200 200 200 200 200 200
12
270 270 240 240 240 240 240 240 240 240 240 240 230 230 230 230 230 230 230 230 230 230 230 230
Double U
(2 DM)
6,9
9
220 220 200 200 200 200 200 200 200 200 200 200 200 200 200
12
With OXY·SENS
®
or condensate separator
2)
I
6,9
≥ 9
U
6,9
≥ 9
120 120
M
6,9
≥ 9
150 150 150 150 150 150 150 150 130 130 130 130 130
Double U
(1 DM)
6,9
9
160 160 160 160 160 160 160 160 160 160
12
190 190 190 190 190 190 190 190 180 180 180 180 180 180 180 180 180 180 180
Double U
(2 DM)
6,9
9
160 160 160 160 160 160 160 160 160 160
12
With detonation prevention device
3)
I
6,9
≥ 9
U
6,9
≥ 9
M
6,9
≥ 9
Double U
(1 DM)
6,9
9
12
Double U
(2 DM)
6,9
9
12
Summary of Contents for Ampac TITANUS PRO-SENS
Page 51: ...MAN3184 TITANUS PRO SENS 51 Figure 34 Pipe shapes...
Page 61: ...MAN3184 TITANUS PRO SENS 61 Figure 36 Example pipe project planning with pipe accessories...
Page 118: ...MAN3184 TITANUS PRO SENS 118 Figure 73 Drill hole intervals for bracket type MT 1 mm...
Page 135: ...MAN3184 TITANUS PRO SENS 135 Figure 84 Attaching the aspiration reducing film sheet...