RS5-34 Telescopic Handler
SLAVE CYLINDER
PRINTED IN U.S.A.
606-2
913241
Alt= to hide template information
Alt+ to display template information
Template Name: OML_2_col
907871E
Template Date: 1997_02_12
G0805102
5. Locate the attachment tilt-down section on the
right side of the control valve and remove the
rubber boot. Using a screwdriver, turn the screw
IN (clockwise) until it bottoms, then turn it OUT
(counterclockwise) until it bottoms. Reinstall the
rubber boot.
SLAVE CYLINDER REMOVAL
STEP 1
G0905005
Disconnect both hydraulic hoses from the slave
cylinder.
STEP 2
Install caps and plugs on all hoses and hydraulic
fittings to prevent contamination of the hydraulic
system.
STEP 3
G0905006
Loosen and remove the retainer bolt (1) and nut (2)
from the lower pivot pin.
STEP 4
G0905007
Remove the lower pivot pin from the slave cylinder.
STEP 5
G0905013
Using a hoist and lifting strap, position the lifting strap
a r o u n d th e sl ave c y l i n d e r a n d a p p l y u p wa r d
pressure.
1
2