TILT CYLINDER COUNTER BALANCE
VALVE QUICK TEST
STEP 39
G0805194
Install a 5000 psi (345 bar) pressure gauge and hose
on the MP test port of the flow divider.
NOTE:
The hose must be long enough to observe
the pressure gauge from inside the cab or
standing clear of the forklift.
STEP 40
G0805077
Start the engine and run at 1000 RPM. Tilt the
attachment mount up until the tilt cylinder reaches
the end of its stroke and hold the joystick in the TILT
UP position. The pressure gauge should read 3000
psi (207 bar).
If the pressure is less than 3000 psi (207 bar) go to
Step 30 of the Tilt Cylinder Direct Test.
If the pressure is 3000 psi (207 bar), proceed to the
next step.
STEP 41
G0805195
Watch the pressure gauge as the attachment mount
is slowly tilted down. The pressure gauge should
read 1500 psi (103 bar) as the attachment mount is
moving downward.
If the pressure is less than 1500 psi (103 bar),
proceed to the next step.
TILT CYLINDER COUNTER BALANCE
VALVE DIRECT TEST
STEP 42
G0805191
Shut off the engine. Install a 5000 psi (345 bar)
pressure gauge and hose (1) between the tilt cylinder
rod end (tilt down) port (2) and the supply hose (3).