FRAME LEVELING CYLINDER DIRECT
TEST
STEP 62
G0805119
Shut off the engine. Remove the hose (1) from the
rod end (tilt right) port (2) of the leveling cylinder.
Install a hose and a 5000 psi (345 bar) pressure
gauge (3) between the hose (1) and port (2).
STEP 63
G0805077
Start the engine and run at 1000 RPM. Hold the
frame leveling joystick in the TILT RIGHT position.
The pressure gauge should read 2000 psi (138 bar).
If the pressure is less than 2000 psi (138 bar),
proceed to the next step.
STEP 64
G0805122
Shut off the engine. Remove the pressure gauge
from the cylinder port (1). Cap the port (1) and plug
the gauge tee adapter (2).
STEP 65
G0805077
Start the engine and run at 1000 RPM. Hold the
frame leveling joystick in the TILT RIGHT position.
The pressure gauge should read 2000 psi (138 bar)
If the pressure is 2000 psi (138 bar), repair or replace
the tilt cylinder.
If the pressure is less than 2000 psi (138 bar),
proceed to the Pump Pressure Test section of this
manual.