RS5-34 Telescopic Handler
ELECTRICAL
PRINTED IN U.S.A.
301-15
913241
Alt= to hide template information
Alt+ to display template information
Template Name: OML_2_col
907871E
Template Date: 1997_02_12
STEP 16
G0805163
Connect the positive (+) test lead to the white/blue
wire terminal of the starter switch. Turn the key switch
to the ON position. With the transmission lever in
neutral the multimeter should read 12 to 13 volts.
If there is no voltage, check the fuse. If the fuse is not
o p e n , r e p l a c e t h e t ra n s m i s s i o n l eve r / sw i t c h
assembly.
If there is 12 to 13 volts, proceed to the next step.
STEP 17
G0805164
Connect the positive (+) test lead to the white wire
terminal of the starter button. Place the transmission
lever in the neutral position, turn the key switch to the
ON position and press the starter switch button. The
multimeter should read 12 to 13 volts.
If there is no voltage, replace the starter switch.
If there is 12 to 13 volts, but there was no voltage at
the starter relay ignition terminal (Step 11), repair or
replace the wire between the switch and relay.
STEP 18
G0805159
Install the key switch (1) and the starter button (2).
STEP 19
G0805182
Install the instrument panel using the six screws.
1
2