DESCRIPTION

This Engineering Technical Information (ETI) bulletin describes installation procedures for NEAX2400
ICS ISDN Primary Rate Interface (PRI). For additional information sources, refer to the documents listed
in the

 References

 section of this ETI.

CONTENTS

PAGE

1. GENERAL DESCRIPTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. ISDN OVERVIEW  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2.1 Layer 1 Physical Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.2 ISDN PRI Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.3 ISDN PRI Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3. HARDWARE/SOFTWARE REQUIREMENTS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. CIRCUIT CARD (PA-24PRT)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5. DATA ASSIGNMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5.1 ISDN PRI Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2 ASYD Command  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.3 ARTD Command  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

5.3.1 ARTD Assignment for “B” Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.3.2 ARTD Assignment for “D” Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

5.4 Examples of Office Data Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

5.4.1 Example 1: ADPC, ACSC and ACIC Commands. . . . . . . . . . . . . . . . . . . 15
5.4.2 Example 2: ADPC, ACSC and ACIC Commands (PA-24PRTB-A)  . . . . 18
5.4.3 External Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

5.5 ACBC Command  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

5.5.1 Floppy Disk Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.5.2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.5.3 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.5.4 Related Reference Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.5.5 Entry Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

6. TEST METHOD  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7. REFERENCES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Summary of Contents for NEAX2400 ICS

Page 1: ...2 ISDN OVERVIEW 2 2 1 Layer 1 Physical Interface 2 2 2 ISDN PRI Protocol 2 2 3 ISDN PRI Services 3 3 HARDWARE SOFTWARE REQUIREMENTS 4 4 CIRCUIT CARD PA 24PRT 4 5 DATA ASSIGNMENT 11 5 1 ISDN PRI Comma...

Page 2: ...data When multiple DS1s for ISDN PRI are provided to a given customer location two methods of using D channels are used The first method uses a D channel for each interface The second method uses one...

Page 3: ...requested or is not recognized by the network the call will be rejected The customer should provide information regarding the types of subscribed services In the case of Local CO where the services s...

Page 4: ...uired software ICS IMG must be version B5 1 or higher ICS MMG must be version B6 4 or higher 2 Required firmware 24 PRT SP 3029 minimum revision Rev 4A 4 CIRCUIT CARD PA 24PRT The diagram below shows...

Page 5: ...ack Set OFF Internal Loop Back Cancel 1 ON External Loop Back Set OFF External Loop Back Cancel 2 ON Payload Loop Back Set OFF Payload Loop Back Cancel 3 ON D Channel Control Block MBR Set OFF D Chann...

Page 6: ...sformer Middle Point Open 4 ON Not Used Fixed to ON SW1 Parts Mounted Face Dip Switch Standard Setting 1 ON Digital PAD ROM Selection Special Specification PROM Spec OFF Digital PAD ROM Selection Stan...

Page 7: ...e Interface is turned off with this card being used at the station line side Table 1 ISDN PRI Switch Descriptions Continued SWITCH NAME SWITCH LOCATION KIND OF SWITCH SWITCH NO SWITCH SETTING MEANING...

Page 8: ...OFF Fixed to OFF This switch is set for Protocol Selection but fixed to OFF for the system 2 ON DCH Mode Selection User side OFF DCH Mode Selection Network side 3 ON D Channel Signal Logic Negative 1...

Page 9: ...LOCATION KIND OF SWITCH SWITCH NO SWITCH SETTING MEANING ON 1 2 3 4 5 6 7 8 SW5 1 SW5 2 SW5 3 PAD Pattern ON OFF ON PAD Pattern 1 OFF OFF ON PAD Pattern 2 ON ON OFF A Loss Bothway OFF ON OFF A Loss Re...

Page 10: ...tch Settings for ISDN PRI MODULE SLOT NO SWITCH NAME SWITCH SHAPE REMARKS MB DOWN SW MODE 5 AT T Note 7 NT Note SW0 SW1 If PAD EPROM chip is used position 1 ON If PAD chip is not used position 1 OFF S...

Page 11: ...e connection is necessary Table 3 Lamp Indications LAMP NAME COLOR STATE OPE Note Green Remains lit while this circuit card is operating N OPE Red Remains lit while this circuit card is in make busy s...

Page 12: ...he B route access code AFRS Assign the necessary numbers for specific OPRs AOPR Assign the route of the B channels ACBC Assign the services associated with the specific OPR if necessary ACNP Assign CN...

Page 13: ...TA DATA NAME DATA OSGS 0 OC 0 TPQ 0 ONSG 2 R L 0 BL 0 ISGS 0 RVSD 0 TRKS 0 INSG 2 TL 0 DPLY 1 TF 3 ANS 1 ACD 0 TCL 1 TELP 0 2W 4W 0 L T 1 PAD 4 FAAT 0 RLP 2 OGRL 1 GW 0 TQ 0 ICRL 1 TCMA 0 SMDR 1 HD 0...

Page 14: ...DATA NAME DATA OSGS 0 OC 0 TPQ 0 ONSG 2 R L 0 BL 0 ISGS 0 RVSD 0 TRKS 0 INSG 2 TL 0 DPLY 0 TF 0 ANS 0 ACD 0 TCL 1 TELP 0 2W 4W 0 L T 1 PAD 7 Note 1 FAAT 0 RLP 2 OGRL 0 GW 0 TQ 0 ICRL 0 TCMA 0 SMDR 0...

Page 15: ...of Office Data Programming for a 32 Port Slot No of ISDN Links CHANNEL NAME OF ISDN LINE ADPC ACSC ACIC RT PC CSCG DCH LEN CSCG PC 1 D CHANNEL 10 1 130 00012 130 1 B CHANNEL 11 1 131 00012 2 D CHANNEL...

Page 16: ...T11 B Route PC 1 RT10 D Route PC 1 ACIC PC1 CSC 130 No LEN Space Bar 2 times WRT Y ACSC 130 LEN of the DCH D Channel See Figure 1 131 Same LEN as 130 Figure 1 shows an example of office data assignmen...

Page 17: ...LV7 B16 LV6 B15 LV5 B14 LV4 B13 LV3 B12 LV2 B11 LV1 B10 LV0 B9 LV7 B8 LV6 B7 LV5 B6 LV4 B5 LV3 B4 LV2 B3 LV1 B2 LV0 B1 LV7 LV6 LV5 LV4 LV3 LV2 LV1 LV0 D2 Group 14 Group 15 Group 13 Group 12 LEN for C...

Page 18: ...ing The table below shows relations of parameters assigned in ADPC ACSC and ACIC Commands Table 5 Examples of Office Data Programming for a 16 Port Slot No of ISDN Links CHANNEL NAME OF ISDN LINE ADPC...

Page 19: ...e assignment represents the Physical channel on the 24PRT the second assignment represents the D channel handler DCH part of the 24PRT TK8 B TK1 D TK7 B TK23 B TK6 B TK22 B TK5 B TK21 B TK4 B TK20 B T...

Page 20: ...ISDN PRI Installation Notes ETI 152A Page 20 5 4 3 External Interface Accommodation of the LT connector leads of this circuit card are shown in Figure 4 for PA 24PRT Figure 4 24PRT LT Connector Leads...

Page 21: ...Page 21 ETI 152A NEAX2400 ICS ISDN PRI Installation Notes Accommodation of the PL0 LT Cable Connection leads of this circuit card are shown in Figure 5 Figure 5 PLO LT Cable Connection...

Page 22: ...ting Route Diagram 5 5 ACBC Command ACBC Assignment of Call by Call Service 5 5 1 Floppy Disk Name CM09 5 5 2 Function This command is used for assigning deleting and displaying the Call by Call infor...

Page 23: ...vice Mode 0 Call by Call Service INT National International 0 1 0 National Call 1 International Call NET Kind of Network 0 1 0 AT T SERV Feature Service 0 1 0 Feature CODE Facility Coding Value 0 Tran...

Page 24: ...er of Route Advance 0 7 MD Service Mode 0 Call by Call Service INT National International 0 1 0 National Call 1 International Call NET Kind of Network 0 10 0 AT T SERV Feature Service 0 1 1 Service CO...

Page 25: ...Order of Route Advance 0 7 MD Service Mode 0 Call by Call Service INT National International 0 1 0 National Call 1 International Call NET Kind of Network 0 1 0 AT T SERV Feature Service 0 1 1 Service...

Page 26: ...Number 0 4095 RA Order of Route Advance 0 7 MD Service Mode 0 Call by Call Service INT National International 0 1 0 National Call 1 International Call NET Kind of Network 0 1 1 NT SERV Feature Service...

Page 27: ...tern Number 0 4095 RA Order of Route Advance 0 7 MD Service Mode 0 Call by Call Service INT National International 0 1 0 National Call 1 International Call NET Kind of Network 0 1 1 NT SERV Feature Se...

Page 28: ...t purposes only set the ARTD command CDN 64 1 and SW4 element 2 OFF network side You should be able to place calls from Station A via ISDN to Station B Figure 7 shows the connection of two 24PRTs for...

Page 29: ...Page 29 ETI 152A NEAX2400 ICS ISDN PRI Installation Notes 7 REFERENCES Command Manual Stock 200705 ISDN Feature and Specifications Manual Stock 200710...