STEP 91
G0805198
Start the engine and run at 1000 RPM. Hold the
joystick in the position of the function being tested.
(Example shown is Boom RETRACT). The pressure
gauge should read 350 psi (24 bar).
If the pressure is 350 psi (24 bar), repair or replace
the control solenoid.
If the pressure is less than 350 psi (24 bar) proceed
to the next step.
STEP 92
G0805185
Shut off the engine. Remove the pressure gauge
from the solenoid supply hose (1) and install the
supply hose (1) on the solenoid (2).
STEP 93
G0805134
G0805132
Remove the hose (1) from port J (2) of the flow
divider. Install a 1000 psi (69 bar) pressure gauge (3)
on port JP (2) and a plug in the hose end (1).
Start the engine and run at 1000 RPM. The pressure
gauge should read 350 psi (24 bar).
If the pressure is 350 psi (24 bar), repair or replace
the joystick control valve.
If the pressure is less than 350 psi (24 bar), proceed
to the next step.
2
1
2
1
3